{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T21:15:05Z","timestamp":1783631705395,"version":"3.55.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T00:00:00Z","timestamp":1775433600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jsesarthroplasty.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES International"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.jseint.2026.101709","type":"journal-article","created":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T08:29:56Z","timestamp":1775809796000},"page":"101709","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Failure mechanisms of the Exactech Equinoxe hybrid cage glenoid in anatomic TSA: a retrieval and radiographic case series"],"prefix":"10.1016","volume":"10","author":[{"given":"Nathaniel L.","family":"Bailey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4223-0416","authenticated-orcid":false,"given":"Moreica","family":"Pabbruwe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5991-6740","authenticated-orcid":false,"given":"Alan","family":"Kop","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7789-5872","authenticated-orcid":false,"given":"William G.","family":"Blakeney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jseint.2026.101709_bib1","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.jse.2015.10.017","article-title":"Analysis of severely fractured glenoid components: clinical consequences of biomechanics, design, and materials selection on implant performance","volume":"25","author":"Ansari","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2026.101709_bib4","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1177\/1758573218790119","article-title":"Journey of the glenoid in anatomic total shoulder replacement","volume":"11","author":"Castagna","year":"2019","journal-title":"Shoulder Elbow"},{"key":"10.1016\/j.jseint.2026.101709_bib5","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1053\/j.sart.2024.06.006","article-title":"Anatomic total shoulder arthroplasty using hybrid glenoid fixation with a porous-coated titanium post. Two-to ten-year follow-up of 256 cases with primary glenohumeral osteoarthritis","volume":"34","author":"Ceccotti","year":"2024","journal-title":"Semin Arthroplasty"},{"key":"10.1016\/j.jseint.2026.101709_bib6","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.2106\/00004623-200709000-00019","article-title":"Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups","volume":"89","author":"Currier","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2026.101709_bib7","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.arth.2006.07.006","article-title":"In vivo oxidation of gamma-barrier-sterilized ultra-high-molecular-weight polyethylene bearings","volume":"22","author":"Currier","year":"2007","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.jseint.2026.101709_bib8","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/1479-5876-12-74","article-title":"On the inflammatory response in metal-on-metal implants","volume":"12","author":"Dapunt","year":"2014","journal-title":"J Transl Med"},{"key":"10.1016\/j.jseint.2026.101709_bib9","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.mpsur.2019.02.009","article-title":"Surgical management of shoulder arthritis","volume":"37","author":"Evans","year":"2019","journal-title":"Surgery (Oxford)"},{"key":"10.1016\/j.jseint.2026.101709_bib10","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1302\/0301-620X.105B6.BJJ-2022-1033.R2","article-title":"Comparison of long-term clinical and radiological outcomes for cemented keel, cemented peg, and hybrid cage glenoids with anatomical total shoulder arthroplasty using the same humeral component","volume":"105-b","author":"Friedman","year":"2023","journal-title":"Bone Joint J"},{"key":"10.1016\/j.jseint.2026.101709_bib11","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jseint.2021.09.009","article-title":"Comparison of press-fit versus peripherally cemented hybrid glenoid components in anatomic total shoulder arthroplasty: minimum 5-year follow-up","volume":"6","author":"Goodloe","year":"2022","journal-title":"JSES Int"},{"key":"10.1016\/j.jseint.2026.101709_bib12","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1136\/bmj.39339.610000.BE","article-title":"The declaration of Helsinki","volume":"335","author":"Goodyear","year":"2007","journal-title":"BMJ"},{"key":"10.1016\/j.jseint.2026.101709_bib13","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.jisako.2023.04.002","article-title":"Outcomes and survivorship of anatomic total shoulder arthroplasty: current concepts","volume":"8","author":"Italia","year":"2023","journal-title":"J ISAKOS"},{"key":"10.1016\/j.jseint.2026.101709_bib14","doi-asserted-by":"crossref","first-page":"244","DOI":"10.5397\/cise.2021.00738","article-title":"Pathogenesis, evaluation, and management of osteolysis after total shoulder arthroplasty","volume":"25","author":"Kunze","year":"2022","journal-title":"Clin Shoulder Elb"},{"key":"10.1016\/j.jseint.2026.101709_bib15","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.2106\/00004623-200207000-00013","article-title":"The radiographic evaluation of keeled and pegged glenoid component insertion","volume":"84","author":"Lazarus","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.jseint.2026.101709_bib16","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0197614","article-title":"Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement","volume":"13","author":"Lehtovirta","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.jseint.2026.101709_bib17","article-title":"Glenoid prosthesis design considerations in anatomic total shoulder arthroplasty","volume":"6","author":"Liu","year":"2022","journal-title":"J Shoulder Elb Arthroplast"},{"key":"10.1016\/j.jseint.2026.101709_bib18","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.jisako.2023.05.001","article-title":"Anatomic glenohumeral arthroplasty: state of the art","volume":"8","author":"Lukasiewicz","year":"2023","journal-title":"J ISAKOS"},{"key":"10.1016\/j.jseint.2026.101709_bib19","first-page":"113","article-title":"Hybrid fixation in anatomic shoulder arthroplasty: surgical technique and review of the literature","volume":"1","author":"Marigi","year":"2021","journal-title":"JSES Rev Rep Tech"},{"key":"10.1016\/j.jseint.2026.101709_bib20","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1016\/j.jse.2021.12.033","article-title":"Clinical and radiographic outcomes of hybrid glenoid fixation with a central porous titanium post: analysis of 713 consecutive shoulders","volume":"31","author":"Marigi","year":"2022","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.jseint.2026.101709_bib21","doi-asserted-by":"crossref","first-page":"196","DOI":"10.5397\/cise.2025.00136","article-title":"Five-year clinical outcomes of metal-backed, hybrid, and polyethylene glenoid components in total shoulder arthroplasty","volume":"28","author":"McDonald","year":"2025","journal-title":"Clin Shoulder Elbow"},{"key":"10.1016\/j.jseint.2026.101709_bib22","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1007\/s00590-021-03050-9","article-title":"Articular surface failure in hybrid anatomic glenoid components: a unique failure mechanism","volume":"32","author":"Monir","year":"2022","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.jseint.2026.101709_bib23","doi-asserted-by":"crossref","first-page":"2107","DOI":"10.1016\/S0142-9612(00)00399-9","article-title":"Fracture behavior of UHMWPE in non-implanted, shelf-aged knee prostheses after gamma irradiation in air","volume":"22","author":"Pu\u00e9rtolas","year":"2001","journal-title":"Biomaterials"},{"key":"10.1016\/j.jseint.2026.101709_bib24","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s11420-006-9003-6","article-title":"The central role of wear debris in periprosthetic osteolysis","volume":"2","author":"Purdue","year":"2006","journal-title":"HSS J"},{"key":"10.1016\/j.jseint.2026.101709_bib25","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1002\/(SICI)1097-4636(1999)48:3<203::AID-JBM1>3.0.CO;2-R","article-title":"Potential errors in FTIR measurement of oxidation in ultrahigh molecular weight polyethylene implants","volume":"48","author":"Shen","year":"1999","journal-title":"J Biomed Mater Res"}],"container-title":["JSES International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638326000940?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666638326000940?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T20:23:39Z","timestamp":1783628619000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666638326000940"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["S2666638326000940"],"URL":"https:\/\/doi.org\/10.1016\/j.jseint.2026.101709","relation":{},"ISSN":["2666-6383"],"issn-type":[{"value":"2666-6383","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Failure mechanisms of the Exactech Equinoxe hybrid cage glenoid in anatomic TSA: a retrieval and radiographic case series","name":"articletitle","label":"Article Title"},{"value":"JSES International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jseint.2026.101709","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons.","name":"copyright","label":"Copyright"}],"article-number":"101709"}}