{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T17:15:03Z","timestamp":1791911703336,"version":"4.3.4"},"reference-count":55,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100000125","name":"National Institute for Occupational Safety and Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000125","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Safety Research"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1016\/j.jsr.2024.05.004","type":"journal-article","created":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T15:51:24Z","timestamp":1716565884000},"page":"381-391","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"special_numbering":"C","title":["Effects of using an active hand exoskeleton for drilling tasks: A pilot study"],"prefix":"10.1016","volume":"90","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2373-3269","authenticated-orcid":false,"given":"Abdullahi","family":"Ibrahim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5838-3441","authenticated-orcid":false,"given":"Ifeanyi","family":"Okpala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3725-4376","authenticated-orcid":false,"given":"Chukwuma","family":"Nnaji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9145-4865","authenticated-orcid":false,"given":"Abiola","family":"Akanmu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jsr.2024.05.004_b0005","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.apergo.2019.05.014","article-title":"Effects of exoskeleton design and precision requirements on physical demands and quality in a simulated overhead drilling task","volume":"80","author":"Abdulkarim","year":"2019","journal-title":"Applied Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0010","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.apergo.2018.08.004","article-title":"Influences of different exoskeleton designs and tool mass on physical demands and performance in a simulated overhead drilling task","volume":"74","author":"Alabdulkarim","year":"2019","journal-title":"Applied Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0015","doi-asserted-by":"crossref","unstructured":"Asgari, M., Phillips, E. A., Dalton, B. M., Rudl, J. L., & Crouch, D. L. (2020). Design and Performance Evaluation of a Wearable Passive Cable-driven Shoulder Exoskeleton. bioRxiv.","DOI":"10.1101\/2020.05.29.096453"},{"issue":"10","key":"10.1016\/j.jsr.2024.05.004_b0020","doi-asserted-by":"crossref","first-page":"610","DOI":"10.2519\/jospt.2004.34.10.610","article-title":"Work-related musculoskeletal disorders of the hand and wrist: Epidemiology, pathophysiology, and sensorimotor changes","volume":"34","author":"Barr","year":"2004","journal-title":"Journal of Orthopaedic & Sports Physical Therapy"},{"key":"10.1016\/j.jsr.2024.05.004_b0030","unstructured":"Bioservo (2022b) \u201cIronhand Brochure\u201d Retrieved from: < https:\/\/www.bioservo.com\/assets\/documents\/Ironhand_Brochure.pdf> (February 1, 2022)."},{"key":"10.1016\/j.jsr.2024.05.004_b0040","unstructured":"BLS (Bureau of Labor Statistics) (2022), Injuries, Illnesses, and Fatalities, Available via https:\/\/www.bls.gov\/iif\/home.htm [Accessed: February, 2023]."},{"key":"10.1016\/j.jsr.2024.05.004_b0045","first-page":"111","article-title":"Exoskeleton and humanoid robotic technology in construction and built environment","author":"Bock","year":"2012","journal-title":"The Future of Humanoid Robots-Research and Applications"},{"key":"10.1016\/j.jsr.2024.05.004_b0060","doi-asserted-by":"crossref","first-page":"182","DOI":"10.3389\/frobt.2020.595862","article-title":"An assistive soft wrist exosuit for flexion movements with an ergonomic reinforced glove","volume":"7","author":"Chiaradia","year":"2021","journal-title":"Frontiers in Robotics and AI"},{"key":"10.1016\/j.jsr.2024.05.004_b0065","doi-asserted-by":"crossref","unstructured":"Cho, Y. K., Kim, K., Ma, S., & Ueda, J. (2018). A robotic wearable exoskeleton for construction workers\u2019 safety and health. In ASCE construction research congress (pp. 19-28).","DOI":"10.1061\/9780784481288.003"},{"key":"10.1016\/j.jsr.2024.05.004_b0070","unstructured":"Colaboratory: Frequently Asked Questions, Jan. 2023, [online] Available: https:\/\/research.google.com\/colaboratory\/faq.html."},{"issue":"3","key":"10.1016\/j.jsr.2024.05.004_b0075","doi-asserted-by":"crossref","first-page":"2416","DOI":"10.1109\/LRA.2018.2813403","article-title":"ForceHand glove: A wearable force-feedback glove with pneumatic artificial muscles (PAMs)","volume":"3","author":"Das","year":"2018","journal-title":"IEEE Robotics and Automation Letters"},{"issue":"6","key":"10.1016\/j.jsr.2024.05.004_b0090","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1080\/00140139.2020.1868581","article-title":"The effectivity of a passive arm support exoskeleton in reducing muscle activation and perceived exertion during plastering activities","volume":"64","author":"de Vries","year":"2021","journal-title":"Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0095","unstructured":"European Agency for Safety and Health at Work (2019). \u201cWork-related musculoskeletal disorders: prevalence, costs and demographics in the EU,\u201d Available via https:\/\/osha.europa.eu\/en\/publications\/msds-facts-and-figures-overview-prevalence-costs-and-demographics-msds-europe [Accessed: February, 2023]."},{"key":"10.1016\/j.jsr.2024.05.004_b0105","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/B978-0-12-814659-0.00008-4","article-title":"Hand exoskeleton systems\u2014Overview","author":"Ferguson","year":"2020","journal-title":"Wearable Robotics"},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0110","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.ergon.2012.11.012","article-title":"Effects of grip type and wrist posture on forearm EMG activity, endurance time and movement accuracy","volume":"43","author":"Finneran","year":"2013","journal-title":"International Journal of Industrial Ergonomics"},{"issue":"10","key":"10.1016\/j.jsr.2024.05.004_b0120","doi-asserted-by":"crossref","first-page":"2276","DOI":"10.1109\/TNSRE.2020.3014408","article-title":"Design and experimental evaluation of a semi-passive upper-limb exoskeleton for workers with the motorized tuning of assistance","volume":"28","author":"Grazi","year":"2020","journal-title":"IEEE Transactions on Neural Systems and Rehabilitation Engineering"},{"key":"10.1016\/j.jsr.2024.05.004_b0125","doi-asserted-by":"crossref","first-page":"936","DOI":"10.36680\/j.itcon.2021.050","article-title":"Assessment of a passive wearable robot for reducing low back disorders during rebar work","volume":"26","author":"Gonsalves","year":"2021","journal-title":"Journal of Information Technology in Construction (ITCON)"},{"key":"10.1016\/j.jsr.2024.05.004_b0130","article-title":"EMG frequency spectral characteristics of inspiratory accessory muscles during the shoulder lifting motion in throwing athletes","volume":"13","author":"Hartz","year":"2015","journal-title":"Manual Therapy, Posturology & Rehabilitation Journal"},{"key":"10.1016\/j.jsr.2024.05.004_b0140","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.apergo.2018.02.009","article-title":"Evaluation of a passive exoskeleton for static upper limb activities","volume":"70","author":"Huysamen","year":"2018","journal-title":"Applied Ergonomics"},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0145","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1002\/hrm.21771","article-title":"Understanding employees\u2019 perceptions of human resource practices: Effects of demographic dissimilarity to managers and coworkers","volume":"56","author":"Jiang","year":"2017","journal-title":"Human Resource Management"},{"issue":"6","key":"10.1016\/j.jsr.2024.05.004_b0150","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1080\/00140139.2020.1870162","article-title":"Effects of industrial back-support exoskeletons on body loading and user experience: An updated systematic review","volume":"64","author":"Kermavnar","year":"2021","journal-title":"Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0165","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.apergo.2018.02.025","article-title":"Assessing the influence of a passive, upper extremity exoskeletal vest for tasks requiring arm elevation: Part I\u2013\u201cExpected\u201d effects on discomfort, shoulder muscle activity, and work task performance","volume":"70","author":"Kim","year":"2018","journal-title":"Applied Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0170","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.apergo.2018.02.024","article-title":"Assessing the influence of a passive, upper extremity exoskeletal vest for tasks requiring arm elevation: Part II\u2013\u201cUnexpected\u201d effects on shoulder motion, balance, and spine loading","volume":"70","author":"Kim","year":"2018","journal-title":"Applied Ergonomics"},{"issue":"3\u20134","key":"10.1016\/j.jsr.2024.05.004_b0160","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1080\/24725838.2018.1561557","article-title":"Potential of exoskeleton technologies to enhance safety, health, and performance in construction: Industry perspectives and future research directions","volume":"7","author":"Kim","year":"2019","journal-title":"IISE Transactions on Occupational Ergonomics and Human Factors"},{"key":"10.1016\/j.jsr.2024.05.004_b0190","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jtherbio.2015.07.008","article-title":"Effect of heat on firefighters\u2019 work performance and physiology","volume":"53","author":"Larsen","year":"2015","journal-title":"Journal of Thermal Biology"},{"key":"10.1016\/j.jsr.2024.05.004_b0195","doi-asserted-by":"crossref","first-page":"83","DOI":"10.2478\/hukin-2014-0113","article-title":"Effect of selective muscle training using visual EMG biofeedback on infraspinatus and posterior deltoid","volume":"44","author":"Lim","year":"2014","journal-title":"Journal of Human Kinetics"},{"key":"10.1016\/j.jsr.2024.05.004_b0200","series-title":"StatPearls [Internet]","article-title":"Anatomy, Shoulder and Upper Limb, Forearm Flexor Carpi Ulnaris Muscle","author":"Lung","year":"2022"},{"key":"10.1016\/j.jsr.2024.05.004_b0210","doi-asserted-by":"crossref","DOI":"10.1016\/j.ergon.2022.103323","article-title":"Effects of passive exoskeleton on trunk and gluteal muscle activity, spinal and hip kinematics and perceived exertion for physiotherapists in a simulated chair transfer task: A feasibility study","volume":"90","author":"Man","year":"2022","journal-title":"International Journal of Industrial Ergonomics"},{"issue":"3\u20134","key":"10.1016\/j.jsr.2024.05.004_b0215","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1080\/24725838.2019.1684399","article-title":"Considerations for industrial use: A systematic review of the impact of active and passive upper limb exoskeletons on physical exposures","volume":"7","author":"McFarland","year":"2019","journal-title":"IISE Transactions on Occupational Ergonomics and Human Factors"},{"key":"10.1016\/j.jsr.2024.05.004_b0225","doi-asserted-by":"crossref","DOI":"10.1016\/j.ssci.2022.105943","article-title":"Controlling safety and health challenges intrinsic in exoskeleton use in construction","volume":"157","author":"Nnaji","year":"2023","journal-title":"Safety Science"},{"key":"10.1016\/j.jsr.2024.05.004_b0230","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.psep.2022.01.002","article-title":"Safety and health management response to COVID-19 in the construction industry: A perspective of fieldworkers","volume":"159","author":"Nnaji","year":"2022","journal-title":"Process Safety and Environmental Protection"},{"key":"10.1016\/j.jsr.2024.05.004_b0235","first-page":"637","article-title":"Anatomy, Shoulder and Upper Limb, Hand Flexor Digitorum Superficialis Muscle. Herrmann, C.M., Madigan, M.L., Davidson, B.S., Granata, K.P., 2006. Effect of lumbar extensor fatigue on paraspinal muscle reflexes","volume":"16","author":"Okafor","year":"2019","journal-title":"J. Electromyogr Kinesiol."},{"key":"10.1016\/j.jsr.2024.05.004_b0240","doi-asserted-by":"crossref","unstructured":"Okpala I., Nnaji C., Ogunseiju O., Akanmu A. (2022) \u201cAssessing the Role of Wearable Robotics in the Construction Industry: Potential Safety Benefits, Opportunities, and Implementation Barriers\u201d. In: Jebelli H., Habibnezhad M., Shayesteh S., Asadi S., Lee S. (eds) Automation and Robotics in the Architecture, Engineering, and Construction Industry. Springer, Cham. https:\/\/doi.org\/10.1007\/978-3-030-77163-8_8.","DOI":"10.1007\/978-3-030-77163-8_8"},{"key":"10.1016\/j.jsr.2024.05.004_b0245","unstructured":"OSHA (Occupational Safety and Health Administration), Estimated Costs of Occupational Injuries and Illnesses and Estimated Impact on a Company\u2019s Profitability Worksheet, Available via https:\/\/www.osha.gov\/safetypays\/estimator, (2017) [Accessed: February, 2023]."},{"key":"10.1016\/j.jsr.2024.05.004_b0250","volume":"Vol. 20056","author":"Palastanga","year":"2006"},{"key":"10.1016\/j.jsr.2024.05.004_b0255","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.gaitpost.2021.11.028","article-title":"Effects of back-support exoskeleton use on gait performance and stability during level walking","volume":"92","author":"Park","year":"2022","journal-title":"Gait & Posture"},{"issue":"3","key":"10.1016\/j.jsr.2024.05.004_b0260","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1177\/0018720820907752","article-title":"Evaluation of a lower leg support exoskeleton on floor and below hip height panel work","volume":"62","author":"Pillai","year":"2020","journal-title":"Human Factors"},{"issue":"12","key":"10.1016\/j.jsr.2024.05.004_b0265","doi-asserted-by":"crossref","first-page":"1864","DOI":"10.1080\/00140139.2014.952682","article-title":"Ergonomic evaluation of a wearable assistive device for overhead work","volume":"57","author":"Rashedi","year":"2014","journal-title":"Ergonomics"},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0270","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1081\/COPD-200050655","article-title":"Minimally clinically important difference for the UCSD Shortness of Breath Questionnaire, Borg scale, and visual analog scale","volume":"2","author":"Ries","year":"2005","journal-title":"COPD: Journal of Chronic Obstructive Pulmonary Disease"},{"key":"10.1016\/j.jsr.2024.05.004_b0275","unstructured":"Rose, W. (2011). Electromyogram analysis. Online course material. The University of Delaware. Retrieved July 5, 2016."},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0280","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.jvs.2019.02.056","article-title":"Test-retest reliability, agreement, and minimal detectable change in the 6-minute walk test in patients with intermittent claudication","volume":"71","author":"Sandberg","year":"2020","journal-title":"Journal of Vascular Surgery"},{"issue":"2","key":"10.1016\/j.jsr.2024.05.004_b0285","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.gaitpost.2013.11.008","article-title":"Gluteus minimus: An intramuscular EMG investigation of anterior and posterior segments during gait","volume":"39","author":"Semciw","year":"2014","journal-title":"Gait & Posture"},{"issue":"9","key":"10.1016\/j.jsr.2024.05.004_b0290","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1093\/ptj\/83.9.816","article-title":"Effect of computer keyboard slope on wrist position and forearm electromyography of typists without musculoskeletal disorders","volume":"83","author":"Simoneau","year":"2003","journal-title":"Physical Therapy"},{"key":"10.1016\/j.jsr.2024.05.004_b0295","doi-asserted-by":"crossref","DOI":"10.1016\/j.ergon.2020.102906","article-title":"The effects of a passive exoskeleton on trunk muscle activity and perceived exertion for experienced auxiliary medical service providers in cardiopulmonary resuscitation chest compression","volume":"76","author":"So","year":"2020","journal-title":"International Journal of Industrial Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0300","doi-asserted-by":"crossref","unstructured":"Spada, S., Ghibaudo, L., Carnazzo, C., Di Pardo, M., Chander, D. S., Gastaldi, L., & Cavatorta, M. P. (2019). Physical and virtual assessment of a passive exoskeleton. In Congress of the International Ergonomics Association (pp. 247-257). Springer, Cham.","DOI":"10.1007\/978-3-319-96068-5_28"},{"key":"10.1016\/j.jsr.2024.05.004_b0305","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.apergo.2017.10.008","article-title":"Physiological consequences of using an upper limb exoskeleton during manual handling tasks","volume":"67","author":"Theurel","year":"2018","journal-title":"Applied Ergonomics"},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0310","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ptsp.2013.03.003","article-title":"Sport-specific endurance plank test for the evaluation of global core muscle function","volume":"15","author":"Tong","year":"2014","journal-title":"Physical Therapy in Sport"},{"issue":"11","key":"10.1016\/j.jsr.2024.05.004_b0315","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1017\/S0263574718000693","article-title":"Empowering lower limbs exoskeletons: State-of-the-art","volume":"36","author":"Viteckova","year":"2018","journal-title":"Robotica"},{"key":"10.1016\/j.jsr.2024.05.004_b0320","unstructured":"Walkowski, A. D., & Goldman, E. M. (2019). Anatomy, Shoulder and Upper Limb, Forearm Extensor Carpi Radialis Brevis Muscle."},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0325","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1080\/00140139.2021.1963490","article-title":"A physiological and biomechanical investigation of three passive upper-extremity exoskeletons during simulated overhead work","volume":"65","author":"Weston","year":"2022","journal-title":"Ergonomics"},{"key":"10.1016\/j.jsr.2024.05.004_b0330","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.apergo.2017.11.006","article-title":"Biomechanical evaluation of exoskeleton use on loading of the lumbar spine","volume":"68","author":"Weston","year":"2018","journal-title":"Applied Ergonomics"},{"issue":"1","key":"10.1016\/j.jsr.2024.05.004_b0335","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.bbe.2020.12.010","article-title":"Development and testing of a wearable passive lower-limb support exoskeleton to support industrial workers","volume":"41","author":"Yan","year":"2021","journal-title":"Biocybernetics and Biomedical Engineering"},{"key":"10.1016\/j.jsr.2024.05.004_b0340","doi-asserted-by":"crossref","DOI":"10.1016\/j.jelekin.2020.102478","article-title":"Effects of a passive upper extremity exoskeleton for overhead tasks","volume":"55","author":"Yin","year":"2020","journal-title":"Journal of Electromyography and Kinesiology"},{"key":"10.1016\/j.jsr.2024.05.004_b0345","doi-asserted-by":"crossref","DOI":"10.1016\/j.autcon.2020.103493","article-title":"Exoskeletons for manual material handling\u2013A review and implication for construction applications","volume":"122","author":"Zhu","year":"2021","journal-title":"Automation in Construction"},{"key":"10.1016\/j.jsr.2024.05.004_b0350","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1111\/j.2042-3306.2010.00230.x","article-title":"The activity of the equine rectus abdominal and oblique external abdominal muscles is measured by surface EMG during walk and trot on the treadmill","volume":"42","author":"Zsoldos","year":"2010","journal-title":"Equine Veterinary Journal"}],"container-title":["Journal of Safety Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022437524000574?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022437524000574?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,7]],"date-time":"2024-09-07T16:48:14Z","timestamp":1725727694000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022437524000574"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":55,"alternative-id":["S0022437524000574"],"URL":"https:\/\/doi.org\/10.1016\/j.jsr.2024.05.004","relation":{},"ISSN":["0022-4375"],"issn-type":[{"value":"0022-4375","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effects of using an active hand exoskeleton for drilling tasks: A pilot study","name":"articletitle","label":"Article Title"},{"value":"Journal of Safety Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jsr.2024.05.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 National Safety Council and Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}