{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:04:03Z","timestamp":1789949043083,"version":"4.0.1"},"reference-count":27,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2007,2,1]],"date-time":"2007-02-01T00:00:00Z","timestamp":1170288000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,7,6]],"date-time":"2016-07-06T00:00:00Z","timestamp":1467763200000},"content-version":"vor","delay-in-days":3443,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2007,2]]},"DOI":"10.1016\/j.jtcvs.2006.09.057","type":"journal-article","created":{"date-parts":[[2007,1,26]],"date-time":"2007-01-26T12:43:38Z","timestamp":1169815418000},"page":"517-524","source":"Crossref","is-referenced-by-count":133,"title":["Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device"],"prefix":"10.25013","volume":"133","author":[{"given":"Adam R.","family":"Travis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guruprasad A.","family":"Giridharan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George M.","family":"Pantalos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert D.","family":"Dowling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumanth D.","family":"Prabhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark S.","family":"Slaughter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mike","family":"Sobieski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akif","family":"Undar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Farrar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven C.","family":"Koenig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jtcvs.2006.09.057_bib1","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term mechanical left ventricular assistance for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib2","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1161\/01.CIR.100.11.1189","article-title":"Decreased expression of tumor necrosis factor-alpha in failing human myocardium after mechanical circulatory support: a potential mechanism for cardiac recovery","volume":"100","author":"Torre-Amione","year":"1999","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib3","doi-asserted-by":"crossref","first-page":"2713","DOI":"10.1161\/01.CIR.102.22.2713","article-title":"Chronic unloading by left ventricular assist device reverses contractile dysfunction and alters gene expression in end-stage heart failure","volume":"102","author":"Heerdt","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib4","doi-asserted-by":"crossref","first-page":"2316","DOI":"10.1161\/01.CIR.97.23.2316","article-title":"Myocyte recovery after mechanical circulatory support in humans with end-stage heart failure","volume":"97","author":"Dipla","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib5","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1161\/hc3301.094911","article-title":"Mechanical unloading restores beta-adrenergic responsiveness and reverses receptor down-regulation in the failing human heart","volume":"104","author":"Ogletree-Hughes","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib6","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1161\/01.CIR.91.11.2717","article-title":"Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading","volume":"91","author":"Levin","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib7","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1161\/01.CIR.98.7.656","article-title":"Regression of cellular hypertrophy after left ventricular assist device support","volume":"98","author":"Zafeiridis","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib8","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/S1053-2498(00)00321-1","article-title":"Regression of fibrosis and hypertrophy in failing myocardium following mechanical circulatory support","volume":"20","author":"Bruckner","year":"2001","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib9","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/S1053-2498(01)00408-9","article-title":"Long-term follow-up of Thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function","volume":"21","author":"Farrar","year":"2002","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib10","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.healun.2004.02.017","article-title":"Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices","volume":"24","author":"Thohan","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib11","doi-asserted-by":"crossref","first-page":"3064","DOI":"10.1161\/01.CIR.0000090962.04121.9E","article-title":"Mechanical circulatory support for advanced heart failure: where does it stand in 2003?","volume":"108","author":"Frazier","year":"2003","journal-title":"Circulation"},{"issue":"suppl","key":"10.1016\/j.jtcvs.2006.09.057_bib12","first-page":"III183","article-title":"Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device","volume":"102","author":"Potapov","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib13","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1111\/j.1525-1594.2004.00086.x","article-title":"Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support","volume":"28","author":"Undar","year":"2004","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib14","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1111\/j.1525-1594.1993.tb00418.x","article-title":"Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion","volume":"17","author":"Nose","year":"1993","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib15","series-title":"Mechanical circulatory support","first-page":"106","article-title":"Pulsatile and non-pulsatile perfusion in cardiac surgery; the continuing controversy","author":"Taylor","year":"1995"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib16","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1001\/archsurg.1966.01330050034005","article-title":"Energy equivalent pressure","volume":"93","author":"Shepard","year":"1966","journal-title":"Arch Surg"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib17","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/0003-4975(94)90498-7","article-title":"Hemodynamic analysis could resolve the pulsatile blood flow controversy","volume":"58","author":"Wright","year":"1994","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib18","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1046\/j.1525-1594.2000.06502-3.x","article-title":"Analysis of the arterial blood pressure waveform using Fast Fourier Transform technique during left ventricular nonpulsatile assistance: in vitro study","volume":"24","author":"Kawahito","year":"2000","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib19","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1046\/j.1525-1594.2000.06646.x","article-title":"Analysis of the arterial blood pressure waveform during left ventricular nonpulsatile assistance in animal models","volume":"24","author":"Kawahito","year":"2000","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib20","series-title":"Virtual bio-instrumentation: biomedical, clinical, and healthcare applications in LabVIEW\u00ae","first-page":"180","article-title":"Biomedical patient monitoring, data acquisition, and playback with LabVIEW\u00ae","author":"Drew","year":"2002"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib21","first-page":"229","article-title":"Integrated data acquisition system for medical device testing and physiology research in compliance with Good Laboratory Practices","volume":"38","author":"Koenig","year":"2004","journal-title":"Biomed Instrum Technol"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib22","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/S0010-4825(03)00087-8","article-title":"HEART: an automated beat-to-beat cardiovascular analysis package using Matlab","volume":"34","author":"Schroeder","year":"2004","journal-title":"Comput Biol Med"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib23","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1046\/j.1525-1594.1999.06409.x","article-title":"Defining pulsatile perfusion: quantification in terms of energy equivalent pressure","volume":"23","author":"Undar","year":"1999","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib24","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/01.MAT.0000150326.51377.A0","article-title":"Precise quantification of pressure flow waveforms of a pulsatile ventricular assist device","volume":"51","author":"Undar","year":"2005","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib25","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1097\/01.mat.0000179341.95404.f8","article-title":"Energy equivalent pressure and total hemodynamic energy associated with the pressure flow waveforms of a pediatric pulsatile ventricular assist device","volume":"51","author":"Weiss","year":"2005","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib26","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1097\/00002480-199911000-00017","article-title":"Pulsatile and nonpulsatile flows can be quantified in terms of energy equivalent pressure during cardiopulmonary bypass for direct comparisons","volume":"45","author":"Undar","year":"1999","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2006.09.057_bib27","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1067\/mtc.2001.114931","article-title":"Comparison of six pediatric cardiopulmonary bypass pumps during pulsatile and nonpulsatile perfusion","volume":"122","author":"Undar","year":"2001","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522306019453?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522306019453?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,9]],"date-time":"2019-01-09T12:20:15Z","timestamp":1547036415000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522306019453"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,2]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2007,2]]}},"alternative-id":["S0022522306019453"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2006.09.057","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2007,2]]}}}