{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T17:23:48Z","timestamp":1791307428813,"version":"4.3.1"},"reference-count":25,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2010,11,1]],"date-time":"2010-11-01T00:00:00Z","timestamp":1288569600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2010,11,1]],"date-time":"2010-11-01T00:00:00Z","timestamp":1288569600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2016,7,6]],"date-time":"2016-07-06T00:00:00Z","timestamp":1467763200000},"content-version":"vor","delay-in-days":2074,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jtcvsonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2010,11]]},"DOI":"10.1016\/j.jtcvs.2010.03.043","type":"journal-article","created":{"date-parts":[[2010,5,24]],"date-time":"2010-05-24T04:29:03Z","timestamp":1274675343000},"page":"1181-1188","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":67,"title":["Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model"],"prefix":"10.1016","volume":"140","author":[{"given":"George V.","family":"Letsou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas D.","family":"Pate","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey R.","family":"Gohean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Kurusz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raul G.","family":"Longoria","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Larry","family":"Kaiser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard W.","family":"Smalling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jtcvs.2010.03.043_bib1","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/j.1540-8191.2008.00696.x","article-title":"Past, present, and future of long-term mechanical cardiac support in adults","volume":"23","author":"Christiansen","year":"2008","journal-title":"J Card Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib2","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1111\/j.1540-8191.2008.00606.x","article-title":"Experience with over 1000 implanted ventricular assist devices","volume":"23","author":"Potapov","year":"2008","journal-title":"J Card Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib3","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib4","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib5","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.pbiomolbio.2008.02.002","article-title":"Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process","volume":"97","author":"Klotz","year":"2008","journal-title":"Prog Biophys Mol Biol"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib6","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.healun.2005.11.451","article-title":"Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency?","volume":"25","author":"Letsou","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib7","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jtcvs.2007.08.048","article-title":"Thrombus formation in a HeartMate II left ventricular assist device","volume":"135","author":"Meyer","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib8","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.healun.2009.01.013","article-title":"Assessment of arterial blood pressure during support with an axial flow left ventricular assist device","volume":"28","author":"Myers","year":"2009","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib9","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1109\/10.247808","article-title":"Real-time left ventricular volume of the canine heart from ultrasonic dimension data","volume":"40","author":"Field","year":"1993","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib10","first-page":"H566","article-title":"Left ventricular systolic pressure-volume area correlates with oxygen consumption","volume":"237","author":"Khalafbeigui","year":"1979","journal-title":"Am J Physiol"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib11","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/01.MAT.0000150326.51377.A0","article-title":"Precise quantification of pressure flow waveforms of a pulsatile ventricular assist device","volume":"51","author":"Undar","year":"2005","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib12","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1016\/j.jamcollsurg.2008.11.016","article-title":"INTERMACS: interval analysis of registry data","volume":"208","author":"Holman","year":"2009","journal-title":"J Am Coll Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib13","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term mechanical left ventricular assistance for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib14","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/j.jtcvs.2006.09.124","article-title":"Improving outcomes with long-term \u201cdestination\u201d therapy using left ventricular assist devices","volume":"135","author":"Long","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib15","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib16","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/j.healun.2009.01.005","article-title":"Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients","volume":"28","author":"Kamdar","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib17","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1016\/j.healun.2008.07.007","article-title":"Differences in pulsatile and non-pulsatile mechanical circulatory support in long-term use","volume":"27","author":"Drews","year":"2008","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib18","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.healun.2004.02.017","article-title":"Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices","volume":"24","author":"Thohan","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib19","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.jtcvs.2006.09.057","article-title":"Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device","volume":"133","author":"Travis","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib20","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1046\/j.1525-1594.1999.06408.x","article-title":"The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model","volume":"23","author":"Undar","year":"1999","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib21","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S0003-4975(97)00290-7","article-title":"Effect of cardiopulmonary bypass perfusion protocols on gut tissue oxygenation and blood flow","volume":"64","author":"Ohri","year":"1997","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib22","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/01.MAT.0000150324.02040.B4","article-title":"The effects of pulsatile flow upon renal tissue perfusion during cardiopulmonary bypass: a comparative study of pulsatile and nonpulsatile flow","volume":"51","author":"Kim","year":"2005","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib23","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/00002480-200001000-00024","article-title":"Monitoring regional cerebral oxygen saturation using near-infrared spectroscopy during pulsatile hypothermic cardiopulmonary bypass in a neonatal piglet model","volume":"46","author":"Undar","year":"2000","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib24","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2010.03.043_bib25","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.healun.2003.10.018","article-title":"Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device","volume":"24","author":"Letsou","year":"2005","journal-title":"J Heart Lung Transplant"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522310003788?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522310003788?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T16:47:02Z","timestamp":1758386822000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522310003788"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2010,11]]}},"alternative-id":["S0022522310003788"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2010.03.043","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2010,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model","name":"articletitle","label":"Article Title"},{"value":"The Journal of Thoracic and Cardiovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jtcvs.2010.03.043","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}