{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T11:14:04Z","timestamp":1791976444064,"version":"4.4.0"},"reference-count":36,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"vor","delay-in-days":731,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1016\/j.jtcvs.2014.09.031","type":"journal-article","created":{"date-parts":[[2014,9,18]],"date-time":"2014-09-18T20:21:27Z","timestamp":1411071687000},"page":"281-289","source":"Crossref","is-referenced-by-count":104,"title":["Pathologic von Willebrand factor degradation with a left ventricular assist device occurs via two distinct mechanisms: Mechanical demolition and enzymatic cleavage"],"prefix":"10.1016","volume":"149","author":[{"given":"Carlo R.","family":"Bartoli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Restle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Acker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavan","family":"Atluri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jtcvs.2014.09.031_bib1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.healun.2012.12.004","article-title":"Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients","volume":"32","author":"Kirklin","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib2","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1002\/clc.22096","article-title":"Left ventricular assist devices and gastrointestinal bleeding: a narrative review of case reports and case series","volume":"36","author":"Islam","year":"2013","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib3","first-page":"1328","article-title":"Acquired Von Willebrand syndrome is an early-onset problem in ventricular assist device patients","volume":"40","author":"Heilmann","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib4","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/j.jacc.2010.05.016","article-title":"Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation","volume":"56","author":"Uriel","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib5","doi-asserted-by":"crossref","first-page":"2162","DOI":"10.1016\/j.jacc.2009.02.048","article-title":"Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II)","volume":"53","author":"Klovaite","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib6","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/MAT.0b013e3181e5de0a","article-title":"Comparative analysis of von Willebrand factor profiles in pulsatile and continuous left ventricular assist device recipients","volume":"56","author":"Crow","year":"2010","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib7","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ejcts.2007.12.047","article-title":"Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease","volume":"33","author":"Geisen","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib8","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.athoracsur.2008.10.027","article-title":"Platelet dysfunction in outpatients with left ventricular assist devices","volume":"87","author":"Steinlechner","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib9","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.athoracsur.2010.04.099","article-title":"Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients","volume":"90","author":"Crow","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib10","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1161\/CIRCHEARTFAILURE.109.877597","article-title":"Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device","volume":"3","author":"Meyer","year":"2010","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib11","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/MAT.0b013e318283815c","article-title":"Mechanistic pathway(s) of acquired von Willebrand syndrome with a continuous-flow ventricular assist device: in\u00a0vitro findings","volume":"59","author":"Dassanayaka","year":"2013","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib12","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1016\/j.jtcvs.2013.08.043","article-title":"Insights into the mechanism(s) of von Willebrand factor degradation during mechanical circulatory support","volume":"147","author":"Bartoli","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib13","article-title":"Preclinical models for translational investigations of left ventricular assist device-associated von Willebrand factor degradation","author":"Restle","year":"2014","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib14","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1007\/s10439-011-0444-9","article-title":"Analysis of fluid flow and wall shear stress patterns inside partially filled agitated culture well plates","volume":"40","author":"Salek","year":"2012","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib15","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/j.jvs.2005.01.020","article-title":"Differential effects of orbital and laminar shear stress on endothelial cells","volume":"41","author":"Dardik","year":"2005","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib16","doi-asserted-by":"crossref","first-page":"081002","DOI":"10.1115\/1.4007092","article-title":"A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index","volume":"134","author":"Fraser","year":"2012","journal-title":"J Biomech Eng"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib17","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/S0079-6107(02)00052-4","article-title":"Fluid shear stress and the vascular endothelium: for better and for worse","volume":"81","author":"Resnick","year":"2003","journal-title":"Prog Biophys Mol Biol"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib18","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1182\/blood-2010-01-264507","article-title":"Endothelial von Willebrand factor regulates angiogenesis","volume":"117","author":"Starke","year":"2011","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib19","unstructured":"Diagnostica A. ACTIFLUOR ADAMTS-13 Activity Assay. American Diagnostica, Stamford, CT; Ref 812."},{"key":"10.1016\/j.jtcvs.2014.09.031_bib20","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1146\/annurev.biochem.67.1.395","article-title":"Biochemistry and genetics of von Willebrand factor","volume":"67","author":"Sadler","year":"1998","journal-title":"Annu Rev Biochem"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib21","doi-asserted-by":"crossref","first-page":"2939","DOI":"10.1182\/blood.V88.8.2939.bloodjournal8882939","article-title":"Shear-dependent changes in the three-dimensional structure of human von Willebrand factor","volume":"88","author":"Siedlecki","year":"1996","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib22","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1126\/science.1170905","article-title":"Mechanoenzymatic cleavage of the ultralarge vascular protein von Willebrand factor","volume":"324","author":"Zhang","year":"2009","journal-title":"Science"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib23","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1182\/blood.V83.8.2171.2171","article-title":"Shear stress enhances the proteolysis of von Willebrand factor in normal plasma","volume":"83","author":"Tsai","year":"1994","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib24","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1056\/NEJMoa022831","article-title":"Acquired von Willebrand syndrome in aortic stenosis","volume":"349","author":"Vincentelli","year":"2003","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib25","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib26","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/MAT.0b013e31824363e7","article-title":"von Willebrand factor, shear stress, and ADAMTS13 in hemostasis and thrombosis","volume":"58","author":"Tsai","year":"2012","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib27","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1172\/JCI115376","article-title":"Heterogeneity of plasma von Willebrand factor multimers resulting from proteolysis of the constituent subunit","volume":"88","author":"Dent","year":"1991","journal-title":"J Clin Invest"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib28","doi-asserted-by":"crossref","first-page":"5102","DOI":"10.1182\/blood-2009-07-231597","article-title":"Endothelial cell ADAMTS-13 and VWF: production, release, and VWF string cleavage","volume":"114","author":"Turner","year":"2009","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib29","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.ccl.2011.08.013","article-title":"The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies","volume":"29","author":"Bartoli","year":"2011","journal-title":"Cardiol Clin"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib30","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.jtcvs.2013.10.027","article-title":"Nonphysiologic blood flow triggers endothelial and arterial remodeling in\u00a0vivo: implications for novel left ventricular assist devices with a peripheral anastomosis","volume":"148","author":"Bartoli","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib31","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.healun.2013.11.010","article-title":"Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices","volume":"33","author":"Birschmann","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib32","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.phrs.2011.05.005","article-title":"Matrix metalloproteinase inhibitor properties of tetracyclines: therapeutic potential in cardiovascular diseases","volume":"64","author":"Castro","year":"2011","journal-title":"Pharmacol Res"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib33","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1182\/blood.V89.6.1954","article-title":"Proteolytic cleavage of recombinant type 2A von Willebrand factor mutants R834W and R834Q: inhibition by doxycycline and by monoclonal antibody VP-1","volume":"89","author":"Tsai","year":"1997","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib34","first-page":"1407","article-title":"Doxycycline and minocycline for the management of acne: a review of efficacy and safety with emphasis on clinical implications","volume":"9","author":"Kircik","year":"2010","journal-title":"J Drugs Dermatol"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib35","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1182\/blood-2004-01-0107","article-title":"Effects of inflammatory cytokines on the release and cleavage of the endothelial cell-derived ultralarge von Willebrand factor multimers under flow","volume":"104","author":"Bernardo","year":"2004","journal-title":"Blood"},{"key":"10.1016\/j.jtcvs.2014.09.031_bib36","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1182\/blood-2004-06-2096","article-title":"Fatal congenital thrombotic thrombocytopenic purpura with apparent ADAMTS13 inhibitor: in\u00a0vitro inhibition of ADAMTS13 activity by hemoglobin","volume":"105","author":"Studt","year":"2005","journal-title":"Blood"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522314012896?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522314012896?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,4,17]],"date-time":"2022-04-17T10:39:31Z","timestamp":1650191971000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522314012896"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["S0022522314012896"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2014.09.031","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2015,1]]}}}