{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T04:26:34Z","timestamp":1781670394383,"version":"3.54.5"},"reference-count":28,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2015,7,1]],"date-time":"2015-07-01T00:00:00Z","timestamp":1435708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,7,1]],"date-time":"2015-07-01T00:00:00Z","timestamp":1435708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,7,1]],"date-time":"2017-07-01T00:00:00Z","timestamp":1498867200000},"content-version":"vor","delay-in-days":731,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jtcvsonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2015,7]]},"DOI":"10.1016\/j.jtcvs.2015.02.048","type":"journal-article","created":{"date-parts":[[2015,2,28]],"date-time":"2015-02-28T11:03:02Z","timestamp":1425121382000},"page":"200-207","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Investigation of hemodynamics in an in\u00a0vitro system simulating left ventricular support through the right subclavian artery using 4-dimensional flow magnetic resonance imaging"],"prefix":"10.1016","volume":"150","author":[{"given":"Bernd","family":"Jung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waltraud","family":"Buchenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Ith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Reineke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Friedhelm","family":"Beyersdorf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Benk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jtcvs.2015.02.048_bib1","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jtcvs.2004.04.044","article-title":"Left ventricular assist devices as destination therapy: a new look at survival","volume":"129","author":"Park","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib2","doi-asserted-by":"crossref","first-page":"2282","DOI":"10.1056\/NEJMe0910394","article-title":"Rise of the machines - left ventricular assist devices as permanent therapy for advanced heart failure","volume":"361","author":"Fang","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib3","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/j.jtcvs.2006.09.124","article-title":"Improving outcomes with long-term \u201cdestination\u201d therapy using left ventricular assist devices","volume":"135","author":"Long","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib4","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s11897-011-0050-z","article-title":"Current state of ventricular assist devices","volume":"8","author":"Caccamo","year":"2011","journal-title":"Curr Heart Fail Rep"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib5","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1016\/j.jtcvs.2013.04.012","article-title":"Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery","volume":"147","author":"Maltais","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib6","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.healun.2010.06.006","article-title":"Aortic valve pathophysiology during left ventricular assist device support","volume":"29","author":"John","year":"2010","journal-title":"Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib7","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","article-title":"The development of aortic insufficiency in left ventricular assist device supported patients","volume":"3","author":"Cowger","year":"2010","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib8","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.athoracsur.2011.04.115","article-title":"Late aortic insufficiency related to poor prognosis during left ventricular assist device support","volume":"92","author":"Toda","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib9","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1253\/circj.CJ-10-1106","article-title":"Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device","volume":"75","author":"Hatano","year":"2011","journal-title":"Circ J"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib10","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","article-title":"Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices","volume":"29","author":"Pak","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib11","first-page":"63","article-title":"Aortic root and valve thrombosis after implantation of a left ventricular assist device","volume":"23","author":"Freed","year":"2011","journal-title":"J Invasive Cardiol"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib12","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/s10047-010-0516-x","article-title":"Misplacement of LVAD inflow cannula leads to insufficient output and tissue hypoperfusion","volume":"13","author":"Crumpstone","year":"2010","journal-title":"J Artif Organs"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib13","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1097\/01.MAT.0000136505.27884.F8","article-title":"Effects of left ventricular assist device support and outflow graft location upon aortic blood flow","volume":"50","author":"Litwak","year":"2004","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib14","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.jtcvs.2013.09.069","article-title":"Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta","volume":"147","author":"Karmonik","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib15","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1111\/j.1525-1594.2010.01098.x","article-title":"Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch","volume":"34","author":"Laumen","year":"2010","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib16","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1111\/j.1525-1594.2009.00938.x","article-title":"Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning","volume":"33","author":"Kaufmann","year":"2009","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib17","first-page":"294","article-title":"The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: implantation technique and computer flow modeling","volume":"32","author":"Kar","year":"2005","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib18","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.mat.0000201961.97981.e9","article-title":"Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta","volume":"52","author":"May-Newman","year":"2006","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib19","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1016\/j.jtcvs.2007.05.024","article-title":"Three-dimensional magnetic resonance flow analysis in a ventricular assist device","volume":"134","author":"Markl","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib20","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.jtcvs.2011.01.058","article-title":"Three-dimensional flow characteristics in ventricular assist devices: impact of valve design and operating conditions","volume":"142","author":"Benk","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib21","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1002\/mrm.22983","article-title":"Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit","volume":"67","author":"Lorenz","year":"2012","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib22","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1093\/ejcts\/ezt095","article-title":"Effect of cannula position in the thoracic aorta with continuous left ventricular support: four-dimensional flow-sensitive magnetic resonance imaging in an in\u00a0vitro model","volume":"44","author":"Benk","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"issue":"58 Suppl 2","key":"10.1016\/j.jtcvs.2015.02.048_bib23","doi-asserted-by":"crossref","first-page":"S173","DOI":"10.1055\/s-0029-1240687","article-title":"Partial mechanical long-term support with the CircuLite Synergy pump as bridge-to-transplant in congestive heart failure","author":"Klotz","year":"2010","journal-title":"Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib24","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.jacc.2009.04.023","article-title":"Proof of concept: hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump","volume":"54","author":"Meyns","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib25","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.ejcts.2010.07.049","article-title":"Clinical benefits of partial circulatory support in New York Heart Association Class IIIB and Early Class IV patients","volume":"39","author":"Meyns","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib26","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1111\/aor.12178","article-title":"Reproduction of continuous flow left ventricular assist device experimental data by means of a hybrid cardiovascular model with baroreflex control","volume":"38","author":"Fresiello","year":"2014","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib27","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1093\/ejcts\/ezt041","article-title":"Circulatory support in elderly chronic heart failure patients using the CircuLite Synergy system","volume":"44","author":"Barbone","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jtcvs.2015.02.048_bib28","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1016\/j.jtcvs.2014.05.063","article-title":"Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?","volume":"148","author":"Sabashnikov","year":"2014","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522315002913?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522315002913?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T16:56:14Z","timestamp":1758387374000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522315002913"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["S0022522315002913"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2015.02.048","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2015,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Investigation of hemodynamics in an in\u00a0vitro system simulating left ventricular support through the right subclavian artery using 4-dimensional flow magnetic resonance imaging","name":"articletitle","label":"Article Title"},{"value":"The Journal of Thoracic and Cardiovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jtcvs.2015.02.048","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}