{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T15:43:59Z","timestamp":1772811839380,"version":"3.50.1"},"reference-count":26,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"vor","delay-in-days":731,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100003579","name":"University of Toronto","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003579","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NSERC Discovery Grant"},{"name":"Ted Rogers Centre for Heart Research Innovation Fund"},{"DOI":"10.13039\/100009364","name":"Saving Tiny Hearts Society","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009364","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jtcvsonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2019,11]]},"DOI":"10.1016\/j.jtcvs.2019.03.008","type":"journal-article","created":{"date-parts":[[2019,3,21]],"date-time":"2019-03-21T03:46:52Z","timestamp":1553140012000},"page":"1424-1433.e5","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":23,"title":["Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation"],"prefix":"10.1016","volume":"158","author":[{"given":"W.C. Patrick","family":"Lin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew G.","family":"Doyle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. Lucy","family":"Roche","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osami","family":"Honjo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas L.","family":"Forbes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina H.","family":"Amon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jtcvs.2019.03.008_bib1","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1161\/CIRCULATIONAHA.115.017202","article-title":"Survival prospects and circumstances of death in contemporary adult congenital heart disease patients under follow-up at a large tertiary centre","volume":"132","author":"Diller","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib2","doi-asserted-by":"crossref","first-page":"152","DOI":"10.21037\/acs.2018.01.16","article-title":"Transplantation in the single ventricle population","volume":"7","author":"Kenny","year":"2018","journal-title":"Ann Cardiothorac Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib3","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.jtcvs.2010.04.037","article-title":"Cavopulmonary assist for the univentricular Fontan circulation: von Karman viscous impeller pump (VIP)","volume":"140","author":"Rodefeld","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib4","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1007\/s00348-013-1581-8","article-title":"Experimental characterization of powered Fontan hemodynamics in an idealized total cavopulmonary connection model","volume":"54","author":"Kerlo","year":"2013","journal-title":"Exp Fluids"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib5","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1016\/j.athoracsur.2011.02.031","article-title":"Wang-zwische double-lumen cannula leads to total cavopulmonary support in a failing Fontan sheep model","volume":"91","author":"Wang","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib6","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.jtcvs.2014.04.051","article-title":"A paired membrane umbrella double-lumen cannula ensures consistent cavopulmonary assistance in a Fontan sheep model","volume":"148","author":"Wang","year":"2014","journal-title":"J\u00a0Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib7","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1111\/j.1525-1594.2011.01339.x","article-title":"Mechanical cavopulmonary assistance of a patient-specific Fontan physiology: numerical simulations, lumped parameter modeling, and suction experiments","volume":"35","author":"Throckmorton","year":"2011","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib8","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1111\/aor.12549","article-title":"Pressure-flow experimental performance of new intravascular blood pump designs for Fontan patients","volume":"40","author":"Chopski","year":"2016","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib9","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/MAT.0000000000000162","article-title":"Cavopulmonary support with a microaxial pump for the failing Fontan physiology","volume":"61","author":"Zhu","year":"2015","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib10","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1053\/j.pcsu.2011.01.015","article-title":"Cavopulmonary assist:(Em) powering the univentricular Fontan circulation","volume":"14","author":"Rodefeld","year":"2011","journal-title":"Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib11","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1097\/MAT.0000000000000521","article-title":"In\u00a0vitro examination of the HeartWare CircuLite ventricular assist device in the Fontan connection","volume":"63","author":"Tree","year":"2017","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib12","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1111\/aor.12852","article-title":"HeartWare ventricular assist device implantation in patients with Fontan physiology","volume":"41","author":"Imielski","year":"2017","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib13","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1007\/s13239-018-0342-5","article-title":"Computational investigation of a self-powered Fontan circulation","volume":"9","author":"Ni","year":"2018","journal-title":"Cardiovasc Eng Technol"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib14","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.jtcvs.2018.02.088","article-title":"In\u00a0vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients","volume":"156","author":"Pekkan","year":"2018","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib15","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.jbiomech.2012.10.045","article-title":"Large eddy simulation of powered Fontan hemodynamics","volume":"46","author":"Delorme","year":"2013","journal-title":"J Biomech"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib16","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1007\/s10439-016-1762-8","article-title":"SimVascular: an open source pipeline for cardiovascular simulation","volume":"45","author":"Updegrove","year":"2017","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib17","series-title":"Eurographics Italian Chapter Conference","article-title":"MeshLab: an open-source mesh processing tool","author":"Cignoni","year":"2008"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib18","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1088\/0967-3334\/22\/1\/324","article-title":"Analysis by mathematical model of haemodynamic data in the failing Fontan circulation","volume":"22","author":"Cavalcanti","year":"2001","journal-title":"Physiol Meas"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib19","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.jtcvs.2011.12.061","article-title":"Uniquely shaped cardiovascular stents enhance the pressure generation of intravascular blood pumps","volume":"144","author":"Throckmorton","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib20","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jtcvs.2012.01.082","article-title":"Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist","volume":"145","author":"Giridharan","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib21","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1016\/j.jtcvs.2009.09.046","article-title":"Early thrombus in a HeartMate II left ventricular assist device: a potential cause of hemolysis and diagnostic dilemma","volume":"140","author":"Bhamidipati","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib22","first-page":"17","article-title":"A Couette viscometer for short time shearing of blood","volume":"17","author":"Heuser","year":"1980","journal-title":"Biorheology"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib23","doi-asserted-by":"crossref","first-page":"094501","DOI":"10.1115\/1.4030823","article-title":"Verification benchmarks to assess the implementation of computational fluid dynamics based hemolysis prediction models","volume":"137","author":"Hariharan","year":"2015","journal-title":"J Biomech Eng"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib24","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/MAT.0b013e318254833b","article-title":"Evaluation of Eulerian and Lagrangian models for hemolysis estimation","volume":"58","author":"Taskin","year":"2012","journal-title":"ASAIO J"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib25","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1111\/j.1525-1594.1995.tb02386.x","article-title":"Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump","volume":"19","author":"Bludszuweit","year":"1995","journal-title":"Artif Organs"},{"key":"10.1016\/j.jtcvs.2019.03.008_bib26","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1046\/j.1525-1594.2001.025005341.x","article-title":"Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics","volume":"25","author":"Apel","year":"2001","journal-title":"Artif Organs"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522319306750?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522319306750?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T17:00:26Z","timestamp":1758387626000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522319306750"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["S0022522319306750"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2019.03.008","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2019,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation","name":"articletitle","label":"Article Title"},{"value":"The Journal of Thoracic and Cardiovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jtcvs.2019.03.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 by The American Association for Thoracic Surgery","name":"copyright","label":"Copyright"}]}}