{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T07:21:56Z","timestamp":1772263316575,"version":"3.50.1"},"reference-count":15,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,27]],"date-time":"2024-04-27T00:00:00Z","timestamp":1714176000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","jtcvsonline.org","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.jtcvs.2024.04.017","type":"journal-article","created":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T13:05:38Z","timestamp":1714309538000},"page":"1645-1655.e6","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Low-dose warfarin with a novel mechanical aortic valve: Interim registry results at 5-year follow-up"],"prefix":"10.1016","volume":"168","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9489-038X","authenticated-orcid":false,"given":"Marc W.","family":"Gerdisch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert Carl","family":"Hagberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Perchinsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aung Y.","family":"Oo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahmoud","family":"Loubani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoffrey M.","family":"Tsang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Zacharias","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohanakrishnan","family":"Sathyamoorthy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.jtcvs.2024.04.017_bib1","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1161\/01.CIR.89.2.635","article-title":"Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses","volume":"89","author":"Cannegieter","year":"1994","journal-title":"Circulation"},{"issue":"4","key":"10.1016\/j.jtcvs.2024.04.017_bib2","first-page":"e25","article-title":"2020 ACC\/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Joint Committee on clinical practice guidelines","volume":"77","author":"Otto","year":"2021","journal-title":"Circulation"},{"issue":"13","key":"10.1016\/j.jtcvs.2024.04.017_bib3","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1056\/NEJMoa1300615","article-title":"Dabigatran versus warfarin in patients with mechanical heart valves","volume":"369","author":"Eikelboom","year":"2013","journal-title":"N Engl J Med"},{"issue":"24","key":"10.1016\/j.jtcvs.2024.04.017_bib4","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1016\/j.jacc.2018.03.535","article-title":"Anticoagulation and antiplatelet strategies after On-X mechanical aortic valve replacement","volume":"71","author":"Puskas","year":"2018","journal-title":"J Am Coll Cardiol"},{"issue":"7","key":"10.1016\/j.jtcvs.2024.04.017_bib5","doi-asserted-by":"crossref","DOI":"10.1056\/EVIDoa2300067","article-title":"Apixaban or warfarin in patients with an On-X mechanical aortic valve","volume":"2","author":"Wang","year":"2023","journal-title":"NEJM Evid"},{"issue":"7","key":"10.1016\/j.jtcvs.2024.04.017_bib6","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","article-title":"2021 ESC\/EACTS guidelines for the management of valvular heart disease","volume":"43","author":"Vahanian","year":"2022","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jtcvs.2024.04.017_bib7","series-title":"FDA Approval: On-X Aortic Valves With Less Warfarin","year":"2015"},{"key":"10.1016\/j.jtcvs.2024.04.017_bib8","series-title":"On-X Life Technologies Reports CE Mark Approval","year":"2014"},{"issue":"4","key":"10.1016\/j.jtcvs.2024.04.017_bib9","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.jtcvs.2014.01.004","article-title":"Reduced anticoagulation after mechanical aortic valve replacement: interim results from the Prospective Randomized On-X Valve Anticoagulation Clinical Trial randomized Food and Drug Administration investigational device exemption trial","volume":"147","author":"Puskas","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"5","key":"10.1016\/j.jtcvs.2024.04.017_bib10","first-page":"e84","article-title":"ACC\/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines","volume":"114","author":"American College of Cardiology\/American Heart Association Task Force on Practice Guidelines","year":"2006","journal-title":"Circulation"},{"issue":"4","key":"10.1016\/j.jtcvs.2024.04.017_bib11","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jtcvs.2007.12.002","article-title":"Guidelines for reporting mortality and morbidity after cardiac valve interventions","volume":"135","author":"Akins","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jtcvs.2024.04.017_bib12","series-title":"SAS. Version 9.4","year":"2013"},{"issue":"1","key":"10.1016\/j.jtcvs.2024.04.017_bib13","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.ahj.2010.05.005","article-title":"LOWERing the INtensity of oral anticoaGulant Therapy in patients with bileaflet mechanical aortic valve replacement: results from the \u201cLOWERING-IT\u201d Trial","volume":"160","author":"Torella","year":"2010","journal-title":"Am Heart J"},{"issue":"21","key":"10.1016\/j.jtcvs.2024.04.017_bib14","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1093\/eurheartj\/ehu330","article-title":"Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants","volume":"36","author":"Koertke","year":"2015","journal-title":"Eur Heart J"},{"issue":"7","key":"10.1016\/j.jtcvs.2024.04.017_bib15","article-title":"Self-monitoring and self-management of oral anticoagulation","volume":"7","author":"Heneghan","year":"2016","journal-title":"Cochrane Database Syst Rev"}],"container-title":["The Journal of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522324003593?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022522324003593?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T21:07:52Z","timestamp":1733778472000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022522324003593"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["S0022522324003593"],"URL":"https:\/\/doi.org\/10.1016\/j.jtcvs.2024.04.017","relation":{},"ISSN":["0022-5223"],"issn-type":[{"value":"0022-5223","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Low-dose warfarin with a novel mechanical aortic valve: Interim registry results at 5-year follow-up","name":"articletitle","label":"Article Title"},{"value":"The Journal of Thoracic and Cardiovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jtcvs.2024.04.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of The American Association for Thoracic Surgery.","name":"copyright","label":"Copyright"}]}}