{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T16:00:21Z","timestamp":1770220821977,"version":"3.49.0"},"reference-count":26,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Veterinary Cardiology"],"published-print":{"date-parts":[[2016,9]]},"DOI":"10.1016\/j.jvc.2016.01.003","type":"journal-article","created":{"date-parts":[[2016,3,29]],"date-time":"2016-03-29T23:34:26Z","timestamp":1459294466000},"page":"226-233","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Systolic arterial blood pressure estimated by mitral regurgitation velocity, high definition oscillometry, and Doppler ultrasonography in dogs with naturally occurring degenerative mitral valve disease"],"prefix":"10.1016","volume":"18","author":[{"given":"A.S.","family":"Hanzlicek","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.D.","family":"Baumwart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.E.","family":"Payton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvc.2016.01.003_bib1","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/j.1939-1676.2007.tb03005.x","article-title":"Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown","year":"2007","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2016.01.003_bib2","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/j.1600-0684.2009.00344.x","article-title":"High Definition Oscillometry: a novel technique for non-invasive blood pressure monitoring in the cynomolgus monkey (Macaca fascicularis)","volume":"38","author":"Schmelting","year":"2009","journal-title":"J Med Primatol"},{"key":"10.1016\/j.jvc.2016.01.003_bib3","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1111\/vaa.12035","article-title":"A clinical comparison between a non-invasive blood pressure monitor using high definition oscillometry (Memodiagnostic MD 15\/90 Pro) and invasive arterial blood pressure measurement in anaesthetized dogs","volume":"40","author":"Rysnik","year":"2013","journal-title":"Vet Anaesth Analg"},{"key":"10.1016\/j.jvc.2016.01.003_bib4","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1111\/jvim.12289","article-title":"Comparison of forelimb and hindlimb systolic blood pressures and proteinuria in healthy Shetland Sheepdogs","volume":"28","author":"Scansen","year":"2014","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2016.01.003_bib5","doi-asserted-by":"crossref","first-page":"766","DOI":"10.2460\/ajvr.71.7.766","article-title":"Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs","volume":"71","author":"Chetboul","year":"2010","journal-title":"Am J Vet Res"},{"key":"10.1016\/j.jvc.2016.01.003_bib6","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1152\/ajplegacy.1976.230.1.211","article-title":"Comparison of arterial hemodynamics in the mongrel dog and the racing greyhound","volume":"230","author":"Cox","year":"1976","journal-title":"Am J Physiol"},{"key":"10.1016\/j.jvc.2016.01.003_bib7","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1111\/j.1748-5827.1996.tb02358.x","article-title":"Epidemiological study of blood pressure in domestic dogs","volume":"37","author":"Bodey","year":"1996","journal-title":"J Small Anim Pract"},{"key":"10.1016\/j.jvc.2016.01.003_bib8","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1111\/j.1939-1676.2011.00735.x","article-title":"White-coat effect on systemic blood pressure in retired racing greyhounds","volume":"25","author":"Marino","year":"2011","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2016.01.003_bib9","doi-asserted-by":"crossref","first-page":"212","DOI":"10.2460\/javma.246.2.212","article-title":"Evaluation of the effects of hospital visit stress on physiologic variables in dogs","volume":"246","author":"Bragg","year":"2015","journal-title":"J Am Vet Med Assoc"},{"key":"10.1016\/j.jvc.2016.01.003_bib10","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.1476-4431.2010.00520.x","article-title":"Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs","volume":"20","author":"Bosiack","year":"2010","journal-title":"J Vet Emerg Crit Care (San Antonio)"},{"key":"10.1016\/j.jvc.2016.01.003_bib11","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.rvsc.2014.05.003","article-title":"Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs","volume":"97","author":"Vachon","year":"2014","journal-title":"Res Vet Sci"},{"key":"10.1016\/j.jvc.2016.01.003_bib12","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0034-5288(96)90104-6","article-title":"Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs","volume":"61","author":"Bodey","year":"1996","journal-title":"Res Vet Sci"},{"key":"10.1016\/j.jvc.2016.01.003_bib13","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.2460\/ajvr.67.9.1541","article-title":"Accuracy of an oscillometric blood pressure monitor during phenylephrine-induced hypertension in dogs","volume":"67","author":"McMurphy","year":"2006","journal-title":"Am J Vet Res"},{"key":"10.1016\/j.jvc.2016.01.003_bib14","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1111\/j.1939-1676.2009.0392.x","article-title":"Guidelines for the diagnosis and treatment of canine chronic valvular heart disease","volume":"23","author":"Atkins","year":"2009","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2016.01.003_bib15","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1111\/j.1939-1676.2006.tb00710.x","article-title":"Echocardiographic estimation of systemic systolic blood pressure in dogs with mild mitral regurgitation","volume":"20","author":"Tou","year":"2006","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2016.01.003_bib16","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1016\/j.tvjl.2013.05.040","article-title":"Systolic arterial blood pressure in small-breed dogs with degenerative mitral valve disease: a prospective study of 103 cases (2007\u20132012)","volume":"197","author":"Petit","year":"2013","journal-title":"Vet J"},{"key":"10.1016\/j.jvc.2016.01.003_bib17","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S1760-2734(06)70050-9","article-title":"Regurgitant jet area by Doppler color flow mapping: quantitative assessment of mitral regurgitation severity in dogs","volume":"5","author":"Muzzi","year":"2003","journal-title":"J Vet Cardiol"},{"key":"10.1016\/j.jvc.2016.01.003_bib18","series-title":"Text of Canine and Feline cardiology","first-page":"216","article-title":"Management of heart failure: principles of treatment, therapeutic strategies, and phamacology","author":"Sisson","year":"1999"},{"key":"10.1016\/j.jvc.2016.01.003_bib19","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1292\/jvms.10-0141","article-title":"Echocardiographic estimation of left atrial pressure in beagle dogs with experimentally-induced mitral valve regurgitation","volume":"73","author":"Ishikawa","year":"2011","journal-title":"J Vet Med Sci"},{"key":"10.1016\/j.jvc.2016.01.003_bib20","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1292\/jvms.70.449","article-title":"Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting","volume":"70","author":"Hsiang","year":"2008","journal-title":"J Vet Med Sci"},{"key":"10.1016\/j.jvc.2016.01.003_bib21","first-page":"211","article-title":"Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs","volume":"70","author":"Haberman","year":"2006","journal-title":"Can J Vet Res"},{"key":"10.1016\/j.jvc.2016.01.003_bib22","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1111\/j.1467-2995.2012.00774.x","article-title":"Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs","volume":"40","author":"Seliskar","year":"2013","journal-title":"Vet Anaesth Analg"},{"key":"10.1016\/j.jvc.2016.01.003_bib23","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1111\/j.1748-5827.2010.00938.x","article-title":"Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines","volume":"51","author":"Wernick","year":"2010","journal-title":"J Small Anim Pract"},{"key":"10.1016\/j.jvc.2016.01.003_bib24","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/0735-1097(93)90248-Y","article-title":"Color flow imaging compared with quantitative Doppler assessment of severity of mitral regurgitation: influence of eccentricity of jet and mechanism of regurgitation","volume":"21","author":"Enriquez-Sarano","year":"1993","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jvc.2016.01.003_bib25","series-title":"Veterinary diagnostic ultrasound","first-page":"198","article-title":"Echocardiogrphy","author":"Kienle","year":"1995"},{"key":"10.1016\/j.jvc.2016.01.003_bib26","doi-asserted-by":"crossref","first-page":"962","DOI":"10.2460\/javma.240.8.962","article-title":"Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs","volume":"240","author":"Wernick","year":"2012","journal-title":"J Am Vet Med Assoc"}],"container-title":["Journal of Veterinary Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1760273416000400?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1760273416000400?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,9,5]],"date-time":"2019-09-05T22:51:02Z","timestamp":1567723862000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1760273416000400"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["S1760273416000400"],"URL":"https:\/\/doi.org\/10.1016\/j.jvc.2016.01.003","relation":{},"ISSN":["1760-2734"],"issn-type":[{"value":"1760-2734","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Systolic arterial blood pressure estimated by mitral regurgitation velocity, high definition oscillometry, and Doppler ultrasonography in dogs with naturally occurring degenerative mitral valve disease","name":"articletitle","label":"Article Title"},{"value":"Journal of Veterinary Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvc.2016.01.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}