{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T14:47:15Z","timestamp":1787237235354,"version":"build-2736575974"},"reference-count":16,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Veterinary Cardiology"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1016\/j.jvc.2017.04.002","type":"journal-article","created":{"date-parts":[[2017,5,31]],"date-time":"2017-05-31T20:30:33Z","timestamp":1496262633000},"page":"268-275","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Perceptions of transcatheter device closure of patent ductus arteriosus in veterinary cardiology and evaluation of a canine model to simulate device placement: a preliminary study"],"prefix":"10.1016","volume":"19","author":[{"given":"A.B.","family":"Saunders","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Keefe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.A.","family":"Birch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.A.","family":"Wierzbicki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7001-3761","authenticated-orcid":false,"given":"D.J.","family":"Maitland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvc.2017.04.002_bib1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jvc.2010.04.004","article-title":"Transarterial ductal occlusion using the Amplatz Canine Duct Occluder in 40 dogs","volume":"12","author":"Gordon","year":"2010","journal-title":"J Vet Cardiol"},{"key":"10.1016\/j.jvc.2017.04.002_bib2","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jvc.2006.07.001","article-title":"Angiographic classification of patent ductus arteriosus morphology in the dog","volume":"8","author":"Miller","year":"2006","journal-title":"J Vet Cardiol"},{"key":"10.1016\/j.jvc.2017.04.002_bib3","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1111\/j.1939-1676.2010.0587.x","article-title":"Utility of transesophageal echocardiography for transcatheter occlusion of patent ductus arteriosus in dogs: influence on the decision-making process","volume":"24","author":"Saunders","year":"2010","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2017.04.002_bib4","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S1760-2734(06)70039-X","article-title":"Catheter closure of patent ductus arteriosus in dogs: variation in ductal size requires different techniques","volume":"5","author":"Glaus","year":"2003","journal-title":"J Vet Cardiol"},{"key":"10.1016\/j.jvc.2017.04.002_bib5","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1111\/j.1939-1676.2007.0009.x","article-title":"Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder","volume":"22","author":"Nguyenba","year":"2008","journal-title":"J Vet Intern Med"},{"key":"10.1016\/j.jvc.2017.04.002_bib6","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.ejcts.2009.09.022","article-title":"Migration of an Amplatzer after patent ductus arteriosus closure","volume":"37","author":"Mandegar","year":"2010","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jvc.2017.04.002_bib7","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1002\/ccd.22538","article-title":"Percutaneous closure of patent ductus arteriosus: a multiinstitutional registry comparing multiple devices","volume":"76","author":"Brunetti","year":"2010","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jvc.2017.04.002_bib8","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1177\/1553350615607641","article-title":"Three-dimensional modeling may improve surgical education and clinical practice","volume":"23","author":"Jones","year":"2016","journal-title":"Surg Innov"},{"key":"10.1016\/j.jvc.2017.04.002_bib9","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1053\/j.jvca.2015.05.198","article-title":"Manual skill acquisition during transesophageal echocardiography simulator training of cardiology fellows: a kinematic assessment","volume":"29","author":"Matyal","year":"2015","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.jvc.2017.04.002_bib10","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1089\/end.2007.9985","article-title":"Validation of surgical simulators","volume":"21","author":"McDougall","year":"2007","journal-title":"J Endourol"},{"key":"10.1016\/j.jvc.2017.04.002_bib11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.3138\/jvme.0914-094R1","article-title":"Development and efficacy of a canine pelvic limb model used to teach the cranial drawer and tibial compression tests in the stifle joint","volume":"42","author":"Troy","year":"2015","journal-title":"J Vet Med Educ"},{"key":"10.1016\/j.jvc.2017.04.002_bib12","doi-asserted-by":"crossref","first-page":"190","DOI":"10.3138\/jvme.0815-138R1","article-title":"Evaluation of veterinary student surgical skills preparation for ovariohysterectomy using simulators: a pilot study","volume":"43","author":"Read","year":"2016","journal-title":"J Vet Med Educ"},{"key":"10.1016\/j.jvc.2017.04.002_bib13","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jmbbm.2015.12.014","article-title":"Mechanical and in\u00a0vitro evaluation of an experimental canine patent ductus arteriosus occlusion device","volume":"59","author":"Wierzbicki","year":"2016","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.jvc.2017.04.002_bib14","series-title":"Understanding Medical Education: Evidence, Theory and Practice","first-page":"175","article-title":"Simulation in medical education","author":"Ker","year":"2014"},{"key":"10.1016\/j.jvc.2017.04.002_bib15","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1080\/01421590500046924","article-title":"Features and uses of high-fidelity medical simulations that lead to effective learning: a BEME systematic review","volume":"27","author":"Issenberg","year":"2005","journal-title":"Med Teach"},{"key":"10.1016\/j.jvc.2017.04.002_bib16","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1259\/bjr\/47436030","article-title":"Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination","volume":"85","author":"Johnson","year":"2012","journal-title":"Br J Radiol"}],"container-title":["Journal of Veterinary Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1760273417300267?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1760273417300267?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T04:24:44Z","timestamp":1535775884000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1760273417300267"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["S1760273417300267"],"URL":"https:\/\/doi.org\/10.1016\/j.jvc.2017.04.002","relation":{},"ISSN":["1760-2734"],"issn-type":[{"value":"1760-2734","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Perceptions of transcatheter device closure of patent ductus arteriosus in veterinary cardiology and evaluation of a canine model to simulate device placement: a preliminary study","name":"articletitle","label":"Article Title"},{"value":"Journal of Veterinary Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvc.2017.04.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}