{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T06:14:09Z","timestamp":1785737649578,"version":"3.56.0"},"reference-count":39,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2009,7,1]],"date-time":"2009-07-01T00:00:00Z","timestamp":1246406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,7,1]],"date-time":"2009-07-01T00:00:00Z","timestamp":1246406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvir.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2009,7]]},"DOI":"10.1016\/j.jvir.2009.04.044","type":"journal-article","created":{"date-parts":[[2009,6,5]],"date-time":"2009-06-05T05:55:24Z","timestamp":1244181324000},"page":"927-935","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of a Microporous Thermoplastic Polyurethane\u2013covered Stent with a Self-expanding Bare Nitinol Stent in a Porcine Iliac Artery Model"],"prefix":"10.1016","volume":"20","author":[{"given":"Boris","family":"Radeleff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Grenacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"Christoph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christof M.","family":"Sommer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrike","family":"Stampfl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Ramsauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tina","family":"Henn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Kurz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruben","family":"Lopez-Benitez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irina","family":"Berger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Goetz M.","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2009.04.044_bib1","first-page":"949","article-title":"Endovascular treatment of aortic aneurysms of the abdominal aorta with covered stents","volume":"44","author":"Melissano","year":"1999","journal-title":"Cardiologia"},{"key":"10.1016\/j.jvir.2009.04.044_bib2","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1016\/S1010-7940(02)00064-7","article-title":"Endoluminal stent-graft placement in patients with acute aortic dissection type B","volume":"21","author":"Hutschala","year":"2002","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jvir.2009.04.044_bib3","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jvs.2006.08.074","article-title":"Randomized comparison of percutaneous Viabahn stent grafts vs prosthetic femoral-popliteal bypass in the treatment of superficial femoral arterial occlusive disease","volume":"45","author":"Kedora","year":"2007","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvir.2009.04.044_bib4","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1053\/j.tvir.2004.01.005","article-title":"Endograft use in the femoral and popliteal arteries","volume":"7","author":"Saxon","year":"2004","journal-title":"Tech Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib5","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/01.RVI.0000052290.26939.cb","article-title":"Hemobahn stent-grafts for treatment of femoropopliteal arterial obstructions: midterm results of a prospective trial","volume":"14","author":"Jahnke","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib6","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1177\/152660280100800312","article-title":"Endovascular stent-grafting in the treatment of superficial femoral artery occlusive disease","volume":"8","author":"Bauermeister","year":"2001","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvir.2009.04.044_bib7","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1097\/01.RVI.0000137434.19522.E5","article-title":"Results of a retrospective multicenter trial of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation","volume":"15","author":"Charon","year":"2004","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib8","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S1051-0443(98)70476-2","article-title":"Review of polymeric graft materials for endovascular applications","volume":"9","author":"Palmaz","year":"1998","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib9","first-page":"347","article-title":"Experimental study of the influence of porosity on development of neointima in Gore-Tex grafts: a method to increase long-term patency rate","volume":"47","author":"Kusaba","year":"1981","journal-title":"Am Surg"},{"key":"10.1016\/j.jvir.2009.04.044_bib10","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1148\/radiology.203.1.9122416","article-title":"Iliac arteries: plain and heparin-coated Dacron-covered stent-grafts compared with noncovered metal stents\u2013an experimental study","volume":"203","author":"Sch\u00fcrmann","year":"1997","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2009.04.044_bib11","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1001\/archsurg.1974.01360050092020","article-title":"Interspecies healing of porous arterial prostheses: observations, 1960 to 1974","volume":"109","author":"Sauvage","year":"1974","journal-title":"Arch Surg"},{"key":"10.1016\/j.jvir.2009.04.044_bib12","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1148\/radiology.205.2.9356607","article-title":"Treatment of peripheral vascular disease with stent-grafts","volume":"205","author":"Cragg","year":"1997","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2009.04.044_bib13","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/S1051-0443(07)61384-0","article-title":"Comparison of two stent-grafts with different porosity: in vivo studies in a sheep model","volume":"11","author":"Sch\u00fcrmann","year":"2000","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib14","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1016\/0741-5214(90)90082-L","article-title":"Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosity","volume":"11","author":"Golden","year":"1990","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvir.2009.04.044_bib15","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/BF00239417","article-title":"Biocompatibility of biodegradable and nonbiodegradable polymer-coated stents implanted in porcine peripheral arteries","volume":"18","author":"De Scheerder","year":"1995","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib16","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1097\/01.RVI.0000082982.70522.5D","article-title":"Carbon-coated stents implanted in porcine iliac and renal arteries: histologic and histomorphometric study","volume":"14","author":"Galloni","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib17","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1007\/s10856-005-4733-4","article-title":"Nitinol Carbofilm coated stents for peripheral applications: study in the porcine model","volume":"16","author":"Prunotto","year":"2005","journal-title":"J Mater Sci Mater Med"},{"key":"10.1016\/j.jvir.2009.04.044_bib18","first-page":"316","article-title":"Short- and long-term histopathologic evaluation of stenting using a self-expanding nitinol stent in pig carotid and iliac arteries","volume":"48","author":"Verheye","year":"1999","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jvir.2009.04.044_bib19","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1136\/heart.89.2.133","article-title":"Drug eluting stents: are human and animal studies comparable?","volume":"89","author":"Virmani","year":"2003","journal-title":"Heart"},{"key":"10.1016\/j.jvir.2009.04.044_bib20","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1111\/j.1749-6632.1998.tb09122.x","article-title":"Developing guidelines on the care and use of animals","volume":"862","author":"Bayne","year":"1998","journal-title":"Ann N Y Acad Sci"},{"key":"10.1016\/j.jvir.2009.04.044_bib21","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1007\/s00330-003-2022-5","article-title":"Self-expanding nitinol stents: material and design considerations","volume":"14","author":"Stoeckel","year":"2004","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib22","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.rli.0000261439.90760.9d","article-title":"The efficacy of nanoscale poly[bis(trifluoroethoxy) phosphazene] (PTFEP) coatings in reducing thrombogenicity and late in-stent stenosis in a porcine coronary artery model","volume":"42","author":"Satzl","year":"2007","journal-title":"Invest Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib23","doi-asserted-by":"crossref","first-page":"1867","DOI":"10.1161\/01.CIR.0000033485.20594.6F","article-title":"Drug-eluting stents in preclinical studies: recommended evaluation from a consensus group","volume":"106","author":"Schwartz","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jvir.2009.04.044_bib24","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/S0735-1097(97)00450-6","article-title":"In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia","volume":"31","author":"Kornowski","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib25","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1056\/NEJMoa051175","article-title":"Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization","volume":"353","author":"Windecker","year":"2005","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jvir.2009.04.044_bib26","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/S1076-6332(05)80151-5","article-title":"Intraarterial biocompatibility of polyethylene terephthalate self-expandable stents implanted in porcine peripheral arteries","volume":"2","author":"De Scheerder","year":"1995","journal-title":"Acad Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib27","first-page":"120","article-title":"Polyurethane and silicone: myths and misconceptions","volume":"18","author":"Brown","year":"1995","journal-title":"J Intraven Nurs"},{"key":"10.1016\/j.jvir.2009.04.044_bib28","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1126\/science.158.3807.1481","article-title":"Segmented polyurethane: a new elastomer for biomedical applications","volume":"158","author":"Boretos","year":"1967","journal-title":"Science"},{"key":"10.1016\/j.jvir.2009.04.044_bib29","first-page":"18","article-title":"Polyurethanes in medical devices","volume":"1","author":"Szycher","year":"1991","journal-title":"Med Des Mater"},{"key":"10.1016\/j.jvir.2009.04.044_bib30","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/0142-9612(86)90002-5","article-title":"Surface properties and blood compatibility of polyurethaneureas","volume":"7","author":"Grasel","year":"1986","journal-title":"Biomaterials"},{"key":"10.1016\/j.jvir.2009.04.044_bib31","first-page":"727","article-title":"Development of a reexpandable covered stent for children","volume":"68","author":"Horita","year":"2006","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jvir.2009.04.044_bib32","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/00004424-200206000-00002","article-title":"Experience on endothelial cell adhesion on vascular stents and stent-grafts: first in vitro results","volume":"37","author":"M\u00fcller-H\u00fclsbeck","year":"2002","journal-title":"Invest Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib33","first-page":"202","article-title":"Biocompatibility of polyurethane-coated stents: tissue and vascular aspects","volume":"45","author":"Rechavia","year":"1998","journal-title":"Cathet Cardiovasc Diagn"},{"key":"10.1016\/j.jvir.2009.04.044_bib34","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1002\/(SICI)1097-4636(199606)31:2<235::AID-JBM10>3.0.CO;2-K","article-title":"Surface microarchitectural design in biomedical applications: in vitro transmural endothelialization on microporous segmented polyurethane films fabricated using an excimer laser","volume":"31","author":"Matsuda","year":"1996","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.jvir.2009.04.044_bib35","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1148\/radiology.213.1.r99oc26229","article-title":"Hemodynamics and wall mechanics after stent placement in swine iliac arteries: comparative results from six stent designs","volume":"213","author":"Rolland","year":"1999","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2009.04.044_bib36","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1007\/BF02577615","article-title":"Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries","volume":"19","author":"Wilczek","year":"1996","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib37","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.jvir.2007.12.450","article-title":"Efficacy of a polyphosphazene nanocoat in reducing thrombogenicity, in-stent stenosis, and inflammatory response in porcine renal and iliac artery stents","volume":"19","author":"Henn","year":"2008","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.04.044_bib38","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1583\/05-1704.1","article-title":"Drug-eluting and bare nitinol stents for the treatment of atherosclerotic lesions in the superficial femoral artery: long-term results from the SIROCCO trial","volume":"13","author":"Duda","year":"2006","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvir.2009.04.044_bib39","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/S1051-0443(96)70822-9","article-title":"Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog","volume":"7","author":"Dolmatch","year":"1996","journal-title":"J Vasc Interv Radiol"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044309003571?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044309003571?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T06:00:44Z","timestamp":1760940044000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1051044309003571"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7]]},"references-count":39,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2009,7]]}},"alternative-id":["S1051044309003571"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2009.04.044","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2009,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of a Microporous Thermoplastic Polyurethane\u2013covered Stent with a Self-expanding Bare Nitinol Stent in a Porcine Iliac Artery Model","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular and Interventional Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvir.2009.04.044","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 SIR. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}