{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T13:41:47Z","timestamp":1769089307874,"version":"3.49.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2010,4,1]],"date-time":"2010-04-01T00:00:00Z","timestamp":1270080000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2010,4]]},"DOI":"10.1016\/j.jvir.2009.12.392","type":"journal-article","created":{"date-parts":[[2010,2,21]],"date-time":"2010-02-21T09:39:47Z","timestamp":1266745187000},"page":"470-476","source":"Crossref","is-referenced-by-count":28,"title":["Endovascular Management of Inadvertent Subclavian Artery Catheterization during Subclavian Vein Cannulation"],"prefix":"10.1016","volume":"21","author":[{"given":"Andreas P.","family":"Chemelli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franz","family":"Wiedermann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josef","family":"Klocker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juergen","family":"Falkensammer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Strasak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benedikt V.","family":"Czermak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Waldenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iris E.","family":"Chemelli-Steinguber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2009.12.392_bib1","doi-asserted-by":"crossref","first-page":"291","DOI":"10.2214\/ajr.163.2.8037017","article-title":"The role of sonography in the placement and management of jugular and subclavian central venous catheters","volume":"163","author":"Skolnick","year":"1994","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jvir.2009.12.392_bib2","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1056\/NEJM199412293312602","article-title":"Complications and failures of subclavian-vein catheterization","volume":"331","author":"Mansfield","year":"1994","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jvir.2009.12.392_bib3","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.ejrad.2007.04.002","article-title":"US-guided placement of central vein catheters in patients with disorders of hemostasis","volume":"65","author":"Tercan","year":"2008","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib4","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1002\/bjs.6730","article-title":"Randomized clinical trial comparing venous cutdown with the Seldinger technique for placement of implantable venous access ports","volume":"96","author":"Nocito","year":"2009","journal-title":"Br J Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib5","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s00270-003-0043-8","article-title":"Managing inadvertent arterial catheterization during central venous access procedures","volume":"27","author":"Nicholson","year":"2004","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib6","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1001\/jama.237.5.446a","article-title":"Percutaneous catheter introduction: the Seldinger technique","volume":"237","author":"Conahan","year":"1977","journal-title":"JAMA"},{"key":"10.1016\/j.jvir.2009.12.392_bib7","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1177\/112972980000100306","article-title":"Which is the easiest and safest technique for central venous access?","volume":"1","author":"Pittiruti","year":"2000","journal-title":"J Vasc Access"},{"key":"10.1016\/j.jvir.2009.12.392_bib8","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1177\/014107689709000607","article-title":"Complications of 1303 central venous cannulations","volume":"90","author":"Yilmazlar","year":"1997","journal-title":"J R Soc Med"},{"key":"10.1016\/j.jvir.2009.12.392_bib9","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/j.jvs.2008.04.046","article-title":"Arterial trauma during central venous catheter insertion: case series, review and proposed algorithm","volume":"48","author":"Guilbert","year":"2008","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib10","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1097\/01.RVI.0000071086.76348.8E","article-title":"Percutaneous arterial closure devices","volume":"14","author":"Hoffer","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib11","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1002\/ccd.1198","article-title":"Early clinical experience with the 6 French Angio-Seal device: immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures","volume":"53","author":"Eggebrecht","year":"2001","journal-title":"Cathet Cardiovasc Interv"},{"key":"10.1016\/j.jvir.2009.12.392_bib12","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1007\/BF03044483","article-title":"The Angio-Seal hemostatic puncture closure device","volume":"24","author":"Nash","year":"1999","journal-title":"Herz"},{"key":"10.1016\/j.jvir.2009.12.392_bib13","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.ejrad.2008.04.024","article-title":"Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion","volume":"71","author":"Chemelli","year":"2009","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib14","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1177\/1538574408318476","article-title":"Delayed treatment of a traumatic left subclavian artery pseudoaneurysm","volume":"42","author":"Franz","year":"2008","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib15","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1583\/1545-1550(2003)010<0058:EAEETO>2.0.CO;2","article-title":"Elective and emergent endovascular treatment of subclavian artery aneurysms and injuries","volume":"10","author":"Schoder","year":"2003","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvir.2009.12.392_bib16","doi-asserted-by":"crossref","first-page":"339","DOI":"10.2214\/ajr.169.2.9242733","article-title":"Complications of central venous catheter placement","volume":"169","author":"Spies","year":"1997","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jvir.2009.12.392_bib17","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/j.jamcollsurg.2004.02.015","article-title":"Arterial misplacement of large-caliber cannulas during jugular vein catheterization: case for surgical management","volume":"198","author":"Shah","year":"2004","journal-title":"J Am Coll Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib18","first-page":"537","article-title":"Stent-graft treatment of trauma to the supra-aortic arteries: a review","volume":"48","author":"Schonholz","year":"2007","journal-title":"J Cardiovasc Surg (Torino)"},{"key":"10.1016\/j.jvir.2009.12.392_bib19","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.jvir.2008.12.409","article-title":"Management of subclavian arterial injuries following inadvertent arterial puncture during central venous catheter placement","volume":"20","author":"Abi-Jaoudeh","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib20","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1053\/j.semvascsurg.2005.09.003","article-title":"Treatment of nonaortic aneurysms in the endograft era: aneurysms of the innominate and subclavian arteries","volume":"18","author":"Chambers","year":"2005","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib21","doi-asserted-by":"crossref","first-page":"337","DOI":"10.2176\/nmc.44.337","article-title":"Use of a large angioplasty balloon for predilation is a risk factor for embolic complications in protected carotid stenting","volume":"44","author":"Sadato","year":"2004","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"10.1016\/j.jvir.2009.12.392_bib22","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.jvs.2007.11.009","article-title":"Long-term results of stent graft treatment of subclavian artery injuries: management of choice for stable patients?","volume":"47","author":"du Toit","year":"2008","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib23","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/S1051-0443(07)61804-1","article-title":"Balloon tamponade for the treatment of inadvertent subclavian arterial catheter placement","volume":"11","author":"Alexander","year":"2000","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib24","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1177\/1538574408320173","article-title":"The use of arterial closure devices for incidental arterial injury","volume":"42","author":"Kirkwood","year":"2008","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib25","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S1051-0443(99)70006-0","article-title":"Use of a collagen plug device to seal a subclavian artery puncture secondary to intraarterial dialysis catheter placement","volume":"10","author":"Dowling","year":"1999","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib26","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1007\/s00270-004-0215-1","article-title":"The use of a collagen-based puncture closure device in the subclavian artery after inadvertent introduction of an 11.5 French hemodialysis catheter","volume":"27","author":"Railo","year":"2004","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib27","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1177\/1538574407312657","article-title":"Complications associated with the arterial puncture closure device\u2013Angio-Seal","volume":"42","author":"Kadner","year":"2008","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib28","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1002\/1522-726X(200101)52:1<3::AID-CCD1002>3.0.CO;2-G","article-title":"Complications of femoral artery closure devices","volume":"52","author":"Carey","year":"2001","journal-title":"Cathet Cardiovasc Interv"},{"key":"10.1016\/j.jvir.2009.12.392_bib29","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1016\/j.jvs.2006.07.034","article-title":"Complications associated with the Angio-Seal arterial puncture closing device: intra-arterial deployment and occlusion by dissected plaque","volume":"44","author":"Dregelid","year":"2006","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib30","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0002-9610(99)00246-9","article-title":"Surgical complications from hemostatic puncture closure devices","volume":"178","author":"Eidt","year":"1999","journal-title":"Am J Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib31","first-page":"689","article-title":"Late clinical presentation of femoral artery occlusion after deployment of the Angio-Seal closure device","volume":"14","author":"Ferreira","year":"2002","journal-title":"J Invas Cardiol"},{"key":"10.1016\/j.jvir.2009.12.392_bib32","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1177\/1538574406293760","article-title":"Techniques for managing complications of arterial closure devices","volume":"40","author":"Kalapatapu","year":"2006","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvir.2009.12.392_bib33","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.4065\/80.8.1011","article-title":"Infectious complications of percutaneous vascular closure devices","volume":"80","author":"Sohail","year":"2005","journal-title":"Mayo Clin Proc"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044309016674?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044309016674?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,26]],"date-time":"2019-05-26T04:56:51Z","timestamp":1558846611000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1051044309016674"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4]]},"references-count":33,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2010,4]]}},"alternative-id":["S1051044309016674"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2009.12.392","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2010,4]]}}}