{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T08:09:21Z","timestamp":1771574961323,"version":"3.50.1"},"reference-count":20,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2011,6,1]],"date-time":"2011-06-01T00:00:00Z","timestamp":1306886400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,6,1]],"date-time":"2011-06-01T00:00:00Z","timestamp":1306886400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvir.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2011,6]]},"DOI":"10.1016\/j.jvir.2011.01.430","type":"journal-article","created":{"date-parts":[[2011,4,15]],"date-time":"2011-04-15T14:44:40Z","timestamp":1302878680000},"page":"806-812","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":53,"title":["Retrievability and Device-Related Complications of the G2 Filter: A Retrospective Study of 139 Filter Retrievals"],"prefix":"10.1016","volume":"22","author":[{"given":"Xiaoli","family":"Zhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew D.B.S.","family":"Tam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Bartholomew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James S.","family":"Newman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark J.","family":"Sands","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiping","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2011.01.430_bib1","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/01.RVI.0000203418-39769.0D","article-title":"Guidelines for the use of retrievable and convertible vena cava filters: report from the Society of Interventional Radiology multidisciplinary consensus conference","volume":"17","author":"Kaufman","year":"2006","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib2","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1016\/j.jvir.2007.02.038","article-title":"Caudal migration of a G2 filter during carbon dioxide cavography","volume":"18","author":"Cantwell","year":"2007","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib4","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.jvir.2006.12.732","article-title":"Estimation of trapped thrombus volumes in retrievable inferior vena cava filters: a visual scale","volume":"18","author":"Wang","year":"2007","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib5","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1016\/j.jvir.2009.08.007","article-title":"Technical success and safety of retrieval of the G2 filter in a prospective, multicenter study","volume":"20","author":"Binkert","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib6","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/j.jvir.2009.03.046","article-title":"G2 inferior vena cava filter: retrievability and safety","volume":"20","author":"Charles","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib7","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.jvir.2009.05.039","article-title":"Removal of the G2 filter: differences between implantation times greater and less than 180 days","volume":"20","author":"Lynch","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib8","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.jvir.2008.02.025","article-title":"Recovery G2 inferior vena cava filter: technical success and safety of retrieval","volume":"19","author":"Oliva","year":"2008","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib9","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.jvir.2007.09.019","article-title":"A comparison of clinical outcomes with retrievable and permanent inferior vena cava filters","volume":"19","author":"Kim","year":"2008","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib10","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.jvir.2008.04.012","article-title":"Embedded inferior vena cava filter removal: use of endobronchial forceps","volume":"19","author":"Stavropoulos","year":"2008","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib11","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jvir.2008.10.007","article-title":"Techniques used for difficult retrievals of the Gunther Tulip inferior vena cava filter: experience in 32 patients","volume":"20","author":"Van Ha","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib12","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1097\/01.RVI.0000150029.86869.DE","article-title":"Inferior vena cava filter removal after 317-day implantation","volume":"16","author":"Binkert","year":"2005","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib13","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1016\/j.jvir.2010.04.019","article-title":"Fragmentation, embolization, and left ventricular perforation of a recovery filter","volume":"21","author":"Desjardins","year":"2010","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib14","doi-asserted-by":"crossref","first-page":"335","DOI":"10.2214\/ajr.135.2.335","article-title":"Normal inferior vena cava: caliber changes observed by dynamic ultrasound","volume":"135","author":"Grant","year":"1980","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jvir.2011.01.430_bib15","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1583\/08-2374.1","article-title":"Evaluation of the Crux IVC Filter in an animal model","volume":"15","author":"Murphy","year":"2008","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvir.2011.01.430_bib16","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1016\/j.jvir.2007.06.006","article-title":"Emergency retrieval of a G2 filter after complete migration into the right ventricle","volume":"18","author":"Kuo","year":"2007","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib17","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.blre.2004.08.002","article-title":"The role of vena caval filters in the management of venous thromboembolism","volume":"19","author":"Hann","year":"2005","journal-title":"Blood Rev"},{"key":"10.1016\/j.jvir.2011.01.430_bib18","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1016\/j.jvir.2009.02.017","article-title":"Aortic and vertebral penetration by a G2 inferior vena cava filter: report of a case","volume":"20","author":"Gupta","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2011.01.430_bib19","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1378\/chest.09-1533","article-title":"Vena cava filter occlusion and venous thromboembolism risk in persistently anticoagulated patients: a prospective, observational cohort study","volume":"137","author":"Hajduk","year":"2010","journal-title":"Chest"},{"key":"10.1016\/j.jvir.2011.01.430_bib20","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s00270-009-9664-x","article-title":"Clinical sequelae of thrombus in an inferior vena cava filter","volume":"33","author":"Ahmad","year":"2010","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"Suppl","key":"10.1016\/j.jvir.2011.01.430_bib21","doi-asserted-by":"crossref","first-page":"S110","DOI":"10.1378\/chest.08-0652","article-title":"Antithrombotic and thrombolytic therapy: American College of Chest Physicians evidence-based clinical practice guidelines (8th edition)","volume":"133","author":"Hirsh","year":"2008","journal-title":"Chest"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044311004398?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044311004398?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T06:01:45Z","timestamp":1760940105000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1051044311004398"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,6]]}},"alternative-id":["S1051044311004398"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2011.01.430","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2011,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Retrievability and Device-Related Complications of the G2 Filter: A Retrospective Study of 139 Filter Retrievals","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular and Interventional Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvir.2011.01.430","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 SIR. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}