{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T23:26:20Z","timestamp":1775863580602,"version":"3.50.1"},"reference-count":23,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2016,5]]},"DOI":"10.1016\/j.jvir.2016.01.134","type":"journal-article","created":{"date-parts":[[2016,3,24]],"date-time":"2016-03-24T06:45:39Z","timestamp":1458801939000},"page":"674-681","source":"Crossref","is-referenced-by-count":38,"title":["Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles"],"prefix":"10.1016","volume":"27","author":[{"given":"Sebahat","family":"Ocak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabrice","family":"Duplaquet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacques","family":"Jamart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lionel","family":"Pirard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Birgit","family":"Weynand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Monique","family":"Delos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"Eucher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beno\u00eet","family":"Rondelet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Dupont","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luc","family":"Delaunois","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yves","family":"Sibille","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caroline","family":"Dahlqvist","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2016.01.134_bib1","first-page":"S99","article-title":"Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance","volume":"6","author":"Boskovic","year":"2014","journal-title":"J Thorac Dis"},{"key":"10.1016\/j.jvir.2016.01.134_bib2","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1038\/nrc3775","article-title":"Non-small-cell lung cancers: a heterogeneous set of diseases","volume":"14","author":"Chen","year":"2014","journal-title":"Nat Rev Cancer"},{"key":"10.1016\/j.jvir.2016.01.134_bib3","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1097\/CEJ.0b013e328329d885","article-title":"Efficacy and safety of direct and frontal macrobiopsies in breast cancer","volume":"18","author":"Cornelis","year":"2009","journal-title":"Eur J Cancer Prev"},{"key":"10.1016\/j.jvir.2016.01.134_bib4","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1007\/s00256-011-1191-6","article-title":"Experience with a frontal core biopsy device in soft tissue and bone lesions","volume":"41","author":"Gielen","year":"2012","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib5","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/CEJ.0b013e32833b483d","article-title":"Assessment of microcalcifications with limited number of high-precision macrobiopsies","volume":"19","author":"Harries","year":"2010","journal-title":"Eur J Cancer Prev"},{"key":"10.1016\/j.jvir.2016.01.134_bib6","doi-asserted-by":"crossref","DOI":"10.1007\/s00270-015-1098-z","article-title":"Ct-guided percutaneous transthoracic needle biopsies using 10g large-core needles: initial experience","author":"Lalji","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib7","doi-asserted-by":"crossref","first-page":"115S","DOI":"10.1378\/chest.123.1_suppl.115S","article-title":"Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence","volume":"123","author":"Schreiber","year":"2003","journal-title":"Chest"},{"key":"10.1016\/j.jvir.2016.01.134_bib8","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1097\/JTO.0b013e31824abd9c","article-title":"Radiographic and clinical characterization of false negative results from CT-guided needle biopsies of lung nodules","volume":"7","author":"Gelbman","year":"2012","journal-title":"J Thorac Oncol"},{"key":"10.1016\/j.jvir.2016.01.134_bib9","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.jvir.2010.01.011","article-title":"Quality improvement guidelines for percutaneous needle biopsy","volume":"21","author":"Gupta","year":"2010","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib10","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2307\/2530820","article-title":"Assessment of diagnostic tests when disease verification is subject to selection bias","volume":"39","author":"Begg","year":"1983","journal-title":"Biometrics"},{"key":"10.1016\/j.jvir.2016.01.134_bib11","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2478\/v10019-012-0004-4","article-title":"Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy","volume":"46","author":"Beslic","year":"2012","journal-title":"Radiol Oncol"},{"key":"10.1016\/j.jvir.2016.01.134_bib12","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1183\/09031936.00077706","article-title":"Ultrasound-assisted transthoracic biopsy: fine-needle aspiration or cutting-needle biopsy?","volume":"29","author":"Diacon","year":"2007","journal-title":"Eur Respir J"},{"key":"10.1016\/j.jvir.2016.01.134_bib13","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/j.jvir.2011.01.448","article-title":"Feasibility of CT-guided large-bore biopsy of lung tumors with the use of an outer sheath","volume":"22","author":"Izumi","year":"2011","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib14","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1148\/radiol.13131265","article-title":"C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients","volume":"271","author":"Lee","year":"2014","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2016.01.134_bib15","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0033-8389(05)70161-5","article-title":"Transthoracic needle biopsy","volume":"38","author":"Klein","year":"2000","journal-title":"Radiol Clin North Am"},{"key":"10.1016\/j.jvir.2016.01.134_bib16","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1111\/j.1440-1843.2006.00901.x","article-title":"Does needle size affect diagnostic yield of transthoracic needle biopsy in malignant pulmonary lesions? Comparison of 18-, 22- and 25-gauge needles in surgical specimens","volume":"11","author":"Unver","year":"2006","journal-title":"Respirology"},{"key":"10.1016\/j.jvir.2016.01.134_bib17","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1148\/radiology.198.3.8628859","article-title":"Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients","volume":"198","author":"Klein","year":"1996","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2016.01.134_bib18","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s002680020388","article-title":"Percutaneous needle biopsy of the lung and its impact on patient management","volume":"25","author":"Murphy","year":"2001","journal-title":"World J Surg"},{"key":"10.1016\/j.jvir.2016.01.134_bib19","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1007\/s00330-008-0893-1","article-title":"Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy","volume":"18","author":"Khan","year":"2008","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib20","doi-asserted-by":"crossref","first-page":"1945","DOI":"10.1016\/j.ejrad.2014.06.023","article-title":"Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients","volume":"83","author":"Nour-Eldin","year":"2014","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib21","doi-asserted-by":"crossref","first-page":"W678","DOI":"10.2214\/AJR.10.4659","article-title":"Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management","volume":"196","author":"Wu","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jvir.2016.01.134_bib22","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1259\/bjr.75.897.750731","article-title":"Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies","volume":"75","author":"Richardson","year":"2002","journal-title":"Br J Radiol"},{"key":"10.1016\/j.jvir.2016.01.134_bib23","doi-asserted-by":"crossref","first-page":"37","DOI":"10.2174\/1875692111008010037","article-title":"New direct and frontal tissue acquisition tools for gene expression analysis in personalized medicine","volume":"8","author":"Janssens","year":"2010","journal-title":"Curr Pharmacogenomics Person Med"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105104431600155X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105104431600155X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,14]],"date-time":"2018-09-14T03:52:28Z","timestamp":1536897148000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S105104431600155X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["S105104431600155X"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2016.01.134","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}