{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T20:21:39Z","timestamp":1790713299588,"version":"4.1.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2018,10,1]],"date-time":"2018-10-01T00:00:00Z","timestamp":1538352000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","jvir.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1016\/j.jvir.2018.01.002","type":"journal-article","created":{"date-parts":[[2018,4,6]],"date-time":"2018-04-06T07:39:15Z","timestamp":1523000355000},"page":"1440-1446","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":79,"title":["Evaluation of a CT-Guided Robotic System for Precise Percutaneous Needle Insertion"],"prefix":"10.1016","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7548-5725","authenticated-orcid":false,"given":"Eliel","family":"Ben-David","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moran","family":"Shochat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ido","family":"Roth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isaac","family":"Nissenbaum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Sosna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. Nahum","family":"Goldberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2018.01.002_bib1","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.cgh.2010.09.017","article-title":"CT and MRI improve detection of hepatocellular carcinoma, compared with ultrasound alone, in patients with cirrhosis","volume":"9","author":"Yu","year":"2011","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.jvir.2018.01.002_bib2","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.addr.2013.11.013","article-title":"Recent advances in molecular, multimodal and theranostic ultrasound imaging","volume":"72","author":"Kiessling","year":"2014","journal-title":"Adv Drug Deliv Rev"},{"key":"10.1016\/j.jvir.2018.01.002_bib3","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/MOU.0b013e32835ad3ee","article-title":"MRI-ultrasound fusion for guidance of targeted prostate biopsy","volume":"23","author":"Marks","year":"2013","journal-title":"Curr Opin Urol"},{"key":"10.1016\/j.jvir.2018.01.002_bib4","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/s00270-014-0897-y","article-title":"Real-time US-CT\/MRI image fusion for guidance of thermal ablation of liver tumors undetectable with US: results in 295 cases","volume":"38","author":"Mauri","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2018.01.002_bib5","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1053\/j.tvir.2013.02.012","article-title":"Image fusion during vascular and nonvascular image-guided procedures","volume":"16","author":"Abi-Jaoudeh","year":"2013","journal-title":"Tech Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2018.01.002_bib6","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1109\/TRA.2003.817044","article-title":"Needle insertion modeling and simulation","volume":"19","author":"DiMaio","year":"2003","journal-title":"IEEE Trans Rob Autom"},{"key":"10.1016\/j.jvir.2018.01.002_bib7","series-title":"Modeling of Needle Insertion Forces for Percutaneous Therapies [PhD dissertation]","author":"Simone","year":"2002"},{"key":"10.1016\/j.jvir.2018.01.002_bib8","series-title":"Biomechanics: Mechanical Properties of Living Tissues","author":"Fung","year":"2013"},{"key":"10.1016\/j.jvir.2018.01.002_bib9","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1109\/TRO.2007.898972","article-title":"Image-guided robotic flexible needle steering","volume":"23","author":"Glozman","year":"2007","journal-title":"IEEE Trans Robot"},{"key":"10.1016\/j.jvir.2018.01.002_bib10","series-title":"International Conference on Medical Image Computing and Computer-Assisted Intervention","first-page":"33","article-title":"Needle steering and model-based trajectory planning","author":"DiMaio","year":"2003"},{"key":"10.1016\/j.jvir.2018.01.002_bib11","first-page":"1327","article-title":"Design considerations of new six degrees-of-freedom parallel robots","volume":"2","author":"Sima\u2019an","year":"1998","journal-title":"Proceedings 1998 IEEE International Conference on Robotics and Automation"},{"key":"10.1016\/j.jvir.2018.01.002_bib12","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1109\/EMB.2007.910274","article-title":"INNOMOTION for percutaneous image-guided interventions","volume":"27","author":"Melzer","year":"2008","journal-title":"IEEE Eng Med Biol Mag"},{"key":"10.1016\/j.jvir.2018.01.002_bib13","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1109\/TRA.2003.817072","article-title":"Acubot: a robot for radiological interventions","volume":"19","author":"Stoianovici","year":"2003","journal-title":"IEEE Trans Rob Autom"},{"key":"10.1016\/j.jvir.2018.01.002_bib14","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1080\/13645700600674179","article-title":"Interventional robotic systems: applications and technology state of the art","volume":"15","author":"Cleary","year":"2006","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"10.1016\/j.jvir.2018.01.002_bib15","doi-asserted-by":"crossref","first-page":"45","DOI":"10.3109\/13645706.2014.977299","article-title":"Robotic systems for percutaneous needle-guided interventions","volume":"24","author":"Kettenbach","year":"2015","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"10.1016\/j.jvir.2018.01.002_bib16","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1148\/radiol.2251011133","article-title":"Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician","volume":"225","author":"Solomon","year":"2002","journal-title":"Radiology"},{"issue":"4 Pt 1","key":"10.1016\/j.jvir.2018.01.002_bib17","first-page":"1110","article-title":"Intraoperative optical biopsy during robotic assisted radical prostatectomy using confocal endomicroscopy","volume":"195","author":"Lopez","year":"2016","journal-title":"J\u00a0Urol"},{"key":"10.1016\/j.jvir.2018.01.002_bib18","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.eururo.2014.12.008","article-title":"Systematic review and cumulative analysis of oncologic and functional outcomes after robot-assisted radical cystectomy","volume":"67","author":"Yuh","year":"2015","journal-title":"Eur Urol"},{"key":"10.1016\/j.jvir.2018.01.002_bib19","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.ejogrb.2013.03.009","article-title":"Robotic-assisted laparoscopic surgery in uterine pathology","volume":"169","author":"Saceanu","year":"2013","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"10.1016\/j.jvir.2018.01.002_bib20","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1016\/j.fertnstert.2014.08.020","article-title":"Robotic-assisted surgery in gynecologic oncology","volume":"102","author":"Sinno","year":"2014","journal-title":"Fertil Steril"},{"key":"10.1016\/j.jvir.2018.01.002_bib21","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1111\/bju.13525","article-title":"Pre-biopsy 3-Tesla MRI and targeted biopsy of the index prostate cancer: correlation with robot-assisted radical prostatectomy","volume":"119","author":"Patel","year":"2017","journal-title":"BJU Int"},{"key":"10.1016\/j.jvir.2018.01.002_bib22","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/MOU.0b013e328354833c","article-title":"MRI-guided and robotic-assisted prostate biopsy","volume":"22","author":"F\u00fctterer","year":"2012","journal-title":"Curr Opin Urol"},{"key":"10.1016\/j.jvir.2018.01.002_bib23","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1148\/radiol.2017162856","article-title":"Robotically driven CT-guided needle insertion: preliminary results in phantom and animal experiments","volume":"285","author":"Hiraki","year":"2017","journal-title":"Radiology"},{"key":"10.1016\/j.jvir.2018.01.002_bib24","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.acra.2012.09.020","article-title":"Evaluation of an electromagnetic image-fusion navigation system for biopsy of small lesions: assessment of accuracy in an in\u00a0vivo swine model","volume":"20","author":"Appelbaum","year":"2013","journal-title":"Acad Radiol"},{"key":"10.1016\/j.jvir.2018.01.002_bib25","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1053\/j.tvir.2013.08.011","article-title":"Image-guided fusion and navigation: applications in tumor ablation","volume":"16","author":"Appelbaum","year":"2013","journal-title":"Tech Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2018.01.002_bib26","doi-asserted-by":"crossref","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","author":"Tian","year":"2017","journal-title":"J\u00a0Thorac Dis"},{"key":"10.1016\/j.jvir.2018.01.002_bib27","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1007\/s00330-017-5027-1","article-title":"Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: a single-institution experience","volume":"28","author":"Chang","year":"2018","journal-title":"Eur Radiol"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044318300022?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1051044318300022?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,25]],"date-time":"2018-09-25T20:29:02Z","timestamp":1537907342000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1051044318300022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["S1051044318300022"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2018.01.002","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2018,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of a CT-Guided Robotic System for Precise Percutaneous Needle Insertion","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular and Interventional Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvir.2018.01.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 SIR, 2018","name":"copyright","label":"Copyright"}]}}