{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T21:11:08Z","timestamp":1767906668133,"version":"3.49.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T00:00:00Z","timestamp":1719446400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","jvir.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular and Interventional Radiology"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.jvir.2024.06.028","type":"journal-article","created":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T16:16:56Z","timestamp":1719850616000},"page":"1534-1543.e4","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparing Deposition Characteristics of Various Embolic Particles Using an In\u00a0Vitro Prostate Microvasculature Model"],"prefix":"10.1016","volume":"35","author":[{"given":"Samuel R.","family":"Miller","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaphan R.","family":"Jernigan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4891-8983","authenticated-orcid":false,"given":"Robert J.","family":"Abraham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6601-4814","authenticated-orcid":false,"given":"Gregory D.","family":"Buckner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvir.2024.06.028_bib1","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.crad.2019.12.019","article-title":"The relationship of embolic particle size to patient outcomes in prostate artery embolisation for benign prostatic hyperplasia: a systematic review and meta-regression","volume":"75","author":"Geevarghese","year":"2020","journal-title":"Clin Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib2","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1016\/j.jvir.2018.06.019","article-title":"Comparison of clinical outcomes of prostatic artery embolization with 50-\u03bcm plus 100-\u03bcm polyvinyl alcohol (PVA) particles versus 100-\u03bcm PVA particles alone: a prospective randomized trial","volume":"29","author":"Wang","year":"2018","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib3","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1007\/s00270-016-1443-x","article-title":"Comparative study using 100\u2013300 versus 300\u2013500 \u03bcm microspheres for symptomatic patients due to enlarged-BPH prostates","volume":"39","author":"Gon\u00e7alves","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib4","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.jmbbm.2017.10.034","article-title":"Comparison of microsphere penetration with LC Bead LUMITM versus other commercial microspheres","volume":"78","author":"Caine","year":"2018","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.jvir.2024.06.028_bib5","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1007\/s10856-006-0592-x","article-title":"Comparative in\u00a0vitro evaluation of microspherical embolisation agents","volume":"17","author":"Lewis","year":"2006","journal-title":"J\u00a0Mater Sci Mater Med"},{"key":"10.1016\/j.jvir.2024.06.028_bib6","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/j.jvir.2015.02.022","article-title":"Selective internal radiation therapy: quantifying distal penetration and distribution of resin and glass microspheres in a surrogate arterial model","volume":"26","author":"Jernigan","year":"2015","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib7","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.jmbbm.2010.05.004","article-title":"Elastic characteristics of microspherical embolic agents used for vascular interventional radiology","volume":"3","author":"Hidaka","year":"2010","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.jvir.2024.06.028_bib8","doi-asserted-by":"crossref","first-page":"2161","DOI":"10.1016\/j.jmbbm.2011.08.001","article-title":"Elasticity and viscoelasticity of embolization microspheres","volume":"4","author":"Hidaka","year":"2011","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.jvir.2024.06.028_bib9","doi-asserted-by":"crossref","first-page":"2243","DOI":"10.1007\/s10856-010-4080-y","article-title":"Characterisation of physico-mechanical properties and degradation potential of calcium alginate beads for use in embolisation","volume":"21","author":"Forster","year":"2010","journal-title":"J\u00a0Mater Sci Mater Med"},{"key":"10.1016\/j.jvir.2024.06.028_bib10","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.jvir.2022.07.032","article-title":"Comparison of bolus versus dual-syringe administration systems on glass yttrium-90 microsphere deposition in an in\u00a0vitro microvascular hepatic tumor model","volume":"34","author":"Miller","year":"2023","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib11","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.jvir.2016.07.001","article-title":"Impact of yttrium-90 microsphere density, flow dynamics, and administration technique on spatial distribution: analysis using an in\u00a0vitro model","volume":"28","author":"Caine","year":"2017","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvir.2024.06.028_bib12","series-title":"Cardiovascular biomechanics","first-page":"25","article-title":"Introduction to cardiovascular biomechanics","author":"Hoskins","year":"2017"},{"key":"10.1016\/j.jvir.2024.06.028_bib13","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3390\/diagnostics10050304","article-title":"Can computed tomography perfusion predict treatment response after prostate artery embolization: a feasibility study","volume":"10","author":"Malling","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"10.1016\/j.jvir.2024.06.028_bib14","article-title":"Radiological findings of prostatic arterial anatomy for prostatic arterial embolization: preliminary study in 55 Chinese patients with benign prostatic hyperplasia","volume":"10","author":"Zhang","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.jvir.2024.06.028_bib15","series-title":"Theoretical microfluidics","author":"Bruus","year":"2007"},{"key":"10.1016\/j.jvir.2024.06.028_bib16","series-title":"Deep residual learning for image recognition. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition; June 27\u201330, 2016","first-page":"770","author":"He","year":"2016"},{"key":"10.1016\/j.jvir.2024.06.028_bib17","series-title":"Fully convolutional networks for semantic segmentation. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR); June 7\u201312, 2015","first-page":"3431","author":"Long","year":"2015"},{"key":"10.1016\/j.jvir.2024.06.028_bib18","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.asoc.2018.05.018","article-title":"A\u00a0survey on deep learning techniques for image and video semantic segmentation","volume":"70","author":"Garcia-Garcia","year":"2018","journal-title":"Appl Soft Comput"}],"container-title":["Journal of Vascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105104432400441X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105104432400441X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T19:57:25Z","timestamp":1727121445000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S105104432400441X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":18,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["S105104432400441X"],"URL":"https:\/\/doi.org\/10.1016\/j.jvir.2024.06.028","relation":{},"ISSN":["1051-0443"],"issn-type":[{"value":"1051-0443","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparing Deposition Characteristics of Various Embolic Particles Using an In\u00a0Vitro Prostate Microvasculature Model","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular and Interventional Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvir.2024.06.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 SIR 2024 .","name":"copyright","label":"Copyright"}]}}