{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T22:36:24Z","timestamp":1784068584033,"version":"3.55.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2014,2,1]],"date-time":"2014-02-01T00:00:00Z","timestamp":1391212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"vor","delay-in-days":730,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2014,2]]},"DOI":"10.1016\/j.jvs.2013.08.005","type":"journal-article","created":{"date-parts":[[2013,9,29]],"date-time":"2013-09-29T13:16:52Z","timestamp":1380460612000},"page":"298-306","source":"Crossref","is-referenced-by-count":70,"title":["Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair"],"prefix":"10.1016","volume":"59","author":[{"given":"Frederike A.B.","family":"Grimme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clark J.","family":"Zeebregts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric L.G.","family":"Verhoeven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Foppe","family":"Bekkema","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel M.J.P.","family":"Reijnen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ignace F.J.","family":"Tielliu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvs.2013.08.005_bib1","first-page":"123","article-title":"[A\u00a0self-fixing synthetic blood vessel endoprosthesis]","volume":"137","author":"Volodos'","year":"1986","journal-title":"Vestn Khir Im I I Grek"},{"key":"10.1016\/j.jvs.2013.08.005_bib2","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/S1051-0443(96)70854-0","article-title":"Fenestrated stent-grafts for preserving visceral arterial branches in the treatment of abdominal aortic aneurysms: preliminary experience","volume":"7","author":"Park","year":"1996","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvs.2013.08.005_bib3","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1053\/ejvs.1999.0924","article-title":"A\u00a0fenestrated covered suprarenal aortic stent","volume":"18","author":"Browne","year":"1999","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib4","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.ejvs.2009.02.012","article-title":"Modern treatment of juxtarenal abdominal aortic aneurysms with fenestrated endografting and open repair\u2013a systematic review","volume":"38","author":"Nordon","year":"2009","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib5","doi-asserted-by":"crossref","first-page":"2707","DOI":"10.1161\/CIRCULATIONAHA.111.070334","article-title":"Early results of fenestrated endovascular repair of juxtarenal aortic aneurysms in the United Kingdom","volume":"125","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.jvs.2013.08.005_bib6","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.ejvs.2010.01.004","article-title":"Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single-centre experience","volume":"39","author":"Verhoeven","year":"2010","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib7","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jvs.2004.11.025","article-title":"Fenestrated endovascular grafting: the renal side of the story","volume":"41","author":"Haddad","year":"2005","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib8","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.jvs.2008.11.024","article-title":"Revised duplex criteria and outcomes for renal stents and stent grafts following endovascular repair of juxtarenal and thoracoabdominal aneurysms","volume":"49","author":"Mohabbat","year":"2009","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib9","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1177\/1531003511401423","article-title":"Fenestrated endografts for complex abdominal aortic aneurysms","volume":"22","author":"Mastracci","year":"2010","journal-title":"Perspect Vasc Surg Endovasc Ther"},{"key":"10.1016\/j.jvs.2013.08.005_bib10","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.ejvs.2003.09.007","article-title":"Treatment of short-necked infrarenal aortic aneurysms with fenestrated stent-grafts: short-term results","volume":"27","author":"Verhoeven","year":"2004","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib11","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jvs.2006.02.056","article-title":"Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts","volume":"44","author":"Muhs","year":"2006","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib12","first-page":"131","article-title":"Fenestrated and branched endovascular techniques for thoraco-abdominal aneurysm repair","volume":"46","author":"Verhoeven","year":"2005","journal-title":"J\u00a0Cardiovasc Surg (Torino)"},{"key":"10.1016\/j.jvs.2013.08.005_bib13","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1002\/ccd.21081","article-title":"Fenestrated endovascular grafts for juxtarenal aortic aneurysms: a step by step technical approach","volume":"69","author":"Moore","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jvs.2013.08.005_bib14","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1067\/mva.2002.123763","article-title":"Reporting standards for endovascular aortic aneurysm repair","volume":"35","author":"Chaikof","year":"2002","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib15","doi-asserted-by":"crossref","first-page":"1572","DOI":"10.1161\/01.CIR.0000029805.87199.45","article-title":"Guidelines for the reporting of renal artery revascularization in clinical trials. American Heart Association","volume":"106","author":"Rundback","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jvs.2013.08.005_bib16","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1583\/11-3473.1","article-title":"Pragmatic minimum reporting standards for endovascular abdominal aortic aneurysm repair","volume":"18","author":"Boyle","year":"2011","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvs.2013.08.005_bib17","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1583\/10-3274C.1","article-title":"Reporting on fenestrated endografts: surrogates for outcomes and implications of aneurysm classification, type of repair, and the evolving technique","volume":"8","author":"Oderich","year":"2011","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvs.2013.08.005_bib18","doi-asserted-by":"crossref","first-page":"S79","DOI":"10.1016\/S0720-048X(02)00364-9","article-title":"Multiple detector-row CT angiography of the renal and mesenteric vessels","volume":"45","author":"Fleischmann","year":"2003","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jvs.2013.08.005_bib19","doi-asserted-by":"crossref","first-page":"2265","DOI":"10.1016\/j.ejrad.2011.05.035","article-title":"Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis: findings from a randomized controlled trial","volume":"81","author":"Langenberger","year":"2012","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jvs.2013.08.005_bib20","first-page":"S1","article-title":"K\/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification","volume":"39","year":"2002","journal-title":"Am J Kidney Dis"},{"key":"10.1016\/j.jvs.2013.08.005_bib21","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.jvs.2012.09.071","article-title":"Durability of branches in branched and fenestrated endografts","volume":"57","author":"Mastracci","year":"2013","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib22","doi-asserted-by":"crossref","first-page":"2179","DOI":"10.1016\/S0140-6736(05)66627-5","article-title":"Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial","volume":"365","year":"2005","journal-title":"Lancet"},{"key":"10.1016\/j.jvs.2013.08.005_bib23","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1016\/S0140-6736(05)66628-7","article-title":"Endovascular aneurysm repair and outcome in patients unfit for open repair of abdominal aortic aneurysm (EVAR trial 2): randomised controlled trial","volume":"365","year":"2005","journal-title":"Lancet"},{"key":"10.1016\/j.jvs.2013.08.005_bib24","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1583\/05-1794MR.1","article-title":"Endovascular aneurysm repair alters renal artery movement: a preliminary evaluation using dynamic CTA","volume":"13","author":"Muhs","year":"2006","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvs.2013.08.005_bib25","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1177\/1538574407308200","article-title":"Dynamic cine-computed tomography angiography imaging of standard and fenestrated endografts: differing effects on renal artery motion","volume":"42","author":"Muhs","year":"2008","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvs.2013.08.005_bib26","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1583\/11-3471.1","article-title":"Magnitude of the forces acting on target vessel stents as a result of a mismatch between native aortic anatomy and fenestrated stent-grafts","volume":"18","author":"Oshin","year":"2011","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvs.2013.08.005_bib27","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1080\/136457002760273340","article-title":"A\u00a0survey of stent designs","volume":"11","author":"Stoeckel","year":"2002","journal-title":"Minim Invasive Ther Allied Technol"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521413015176?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521413015176?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,12]],"date-time":"2018-10-12T14:26:41Z","timestamp":1539354401000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521413015176"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,2]]}},"alternative-id":["S0741521413015176"],"URL":"https:\/\/doi.org\/10.1016\/j.jvs.2013.08.005","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2014,2]]}}}