{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T01:56:38Z","timestamp":1790128598551,"version":"4.0.1"},"reference-count":22,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"vor","delay-in-days":730,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000871","name":"Mayo Clinic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvascsurg.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1016\/j.jvs.2021.01.027","type":"journal-article","created":{"date-parts":[[2021,2,5]],"date-time":"2021-02-05T06:50:26Z","timestamp":1612507826000},"page":"372-382.e3","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":22,"title":["Effect of aortic angulation on the outcomes of fenestrated-branched endovascular aortic repair"],"prefix":"10.1016","volume":"74","author":[{"given":"Francesco","family":"Squizzato","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gustavo S.","family":"Oderich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parvathi","family":"Balachandran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emanuel R.","family":"Tenorio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernardo C.","family":"Mendes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Randall R.","family":"De Martino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvs.2021.01.027_bib1","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jvs.2017.10.044","article-title":"The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm","volume":"67","author":"Chaikof","year":"2018","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib2","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1067\/mva.2002.123991","article-title":"Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair","volume":"35","author":"Chaikof","year":"2002","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib3","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1016\/j.jvs.2019.08.250","article-title":"Impact of suprarenal neck angulation on endovascular aneurysm repair outcomes","volume":"71","author":"Mathlouthi","year":"2020","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib4","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1016\/j.jvs.2018.03.427","article-title":"Long-term outcomes of standard endovascular aneurysm repair in patients with severe neck angulation","volume":"68","author":"Oliveira","year":"2018","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib5","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1067\/mva.2002.119506","article-title":"Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair","volume":"35","author":"Sternbergh","year":"2002","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib6","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2014.08.077","article-title":"Computational fluid dynamic analysis of the effect of morphologic features on distraction forces in fenestrated stent grafts","volume":"60","author":"Jones","year":"2014","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib7","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.jvs.2014.06.115","article-title":"Increasing angulation decreases measured aortic stent graft pullout forces","volume":"63","author":"Rahmani","year":"2016","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib8","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.ejvs.2015.12.014","article-title":"Fenestrated endovascular aortic aneurysm repair as a first line treatment option to treat short necked, juxtarenal, and suprarenal aneurysms","volume":"51","author":"Verhoeven","year":"2016","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2016.09.038","article-title":"Prospective, nonrandomized study to evaluate endovascular repair of pararenal and thoracoabdominal aortic aneurysms using fenestrated-branched endografts based on supraceliac sealing zones","volume":"65","author":"Oderich","year":"2017","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib10","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jvs.2018.09.063","article-title":"Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and thoracoabdominal aortic aneurysms","volume":"70","author":"Oderich","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib11","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.jvs.2012.09.071","article-title":"Durability of branches in branched and fenestrated endografts","volume":"57","author":"Mastracci","year":"2013","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2019.07.079","article-title":"Outcomes of directional branches using self-expandable or balloon-expandable stent grafts during endovascular repair of thoracoabdominal aortic aneurysms","volume":"71","author":"Tenorio","year":"2020","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2019.07.080","article-title":"Prospective nonrandomized study to evaluate cone beam computed tomography for technical assessment of standard and complex endovascular aortic repair","volume":"71","author":"Tenorio","year":"2020","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2018.07.040","article-title":"Impact of onlay fusion and cone beam computed tomography on radiation exposure and technical assessment of fenestrated-branched endovascular aortic repair","volume":"69","author":"Tenorio","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib15","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jvs.2009.10.114","article-title":"Validation of a new standardized method to measure proximal aneurysm neck angulation","volume":"51","author":"van Keulen","year":"2010","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2014.08.061","article-title":"Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms","volume":"60","author":"Oderich","year":"2014","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2019.03.026","article-title":"Results from a prospective multicenter feasibility study of Zenith p-Branch stent graft","volume":"70","author":"Farber","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2010.07.008","article-title":"Reporting standards for thoracic endovascular aortic repair (TEVAR)","volume":"52","author":"Fillinger","year":"2010","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib19","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2014.04.038","article-title":"Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms","volume":"60","author":"Mendes","year":"2014","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1583\/06-1914.1","article-title":"Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study","volume":"14","author":"Hobo","year":"2007","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvs.2021.01.027_bib21","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1016\/j.jvs.2014.10.085","article-title":"Type Ia endoleaks after fenestrated and branched endografts may lead to component instability and increased aortic mortality","volume":"61","author":"O\u2019Callaghan","year":"2015","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2021.01.027_bib22","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.ejvs.2010.10.001","article-title":"The suitability of thoraco-abdominal aortic aneurysms for branched or fenestrated stent grafts - and the development of a new scoring method to aid case assessment","volume":"41","author":"Rodd","year":"2011","journal-title":"Eur J Vasc Endovasc Surg"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521421001567?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521421001567?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T20:31:40Z","timestamp":1760041900000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521421001567"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8]]},"references-count":22,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["S0741521421001567"],"URL":"https:\/\/doi.org\/10.1016\/j.jvs.2021.01.027","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of aortic angulation on the outcomes of fenestrated-branched endovascular aortic repair","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvs.2021.01.027","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Published by Elsevier Inc. on behalf of the Society for Vascular Surgery.","name":"copyright","label":"Copyright"}]}}