{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T22:42:07Z","timestamp":1784673727508,"version":"3.55.0"},"reference-count":41,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:00:00Z","timestamp":1765324800000},"content-version":"am","delay-in-days":343,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["5T32HL007734-29"],"award-info":[{"award-number":["5T32HL007734-29"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","jvascsurg.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.jvs.2024.07.108","type":"journal-article","created":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T21:00:38Z","timestamp":1724446838000},"page":"1-12.e1","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":16,"title":["Ten years of physician-modified endografts"],"prefix":"10.1016","volume":"81","author":[{"given":"Andrew P.","family":"Sanders","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7728-4166","authenticated-orcid":false,"given":"Jorge","family":"Gomez-Mayorga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1082-3097","authenticated-orcid":false,"given":"Mohit K.","family":"Manchella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9076-6037","authenticated-orcid":false,"given":"Nicholas J.","family":"Swerdlow","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2052-2573","authenticated-orcid":false,"given":"Marc L.","family":"Schermerhorn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvs.2024.07.108_bib1","first-page":"93","article-title":"Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction","volume":"33","author":"Volodos","year":"1991","journal-title":"Vasa Suppl"},{"key":"10.1016\/j.jvs.2024.07.108_bib2","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/BF02015271","article-title":"Transfemoral intraluminal graft implantation for abdominal aortic aneurysms","volume":"5","author":"Parodi","year":"1991","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib3","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1056\/NEJMoa1405778","article-title":"Long-term outcomes of abdominal aortic aneurysm in the medicare population","volume":"373","author":"Schermerhorn","year":"2015","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jvs.2024.07.108_bib4","doi-asserted-by":"crossref","first-page":"2366","DOI":"10.1016\/S0140-6736(16)31135-7","article-title":"Endovascular versus open repair of abdominal aortic aneurysm in 15-years\u2019 follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomised controlled trial","volume":"388","author":"Patel","year":"2016","journal-title":"Lancet Lond Engl"},{"key":"10.1016\/j.jvs.2024.07.108_bib5","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.surg.2017.01.022","article-title":"Open versus endovascular abdominal aortic aneurysm repair in Medicare beneficiaries","volume":"162","author":"Deery","year":"2017","journal-title":"Surgery"},{"key":"10.1016\/j.jvs.2024.07.108_bib6","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.jvs.2021.01.044","article-title":"Epidemiology of endovascular and open repair for abdominal aortic aneurysms in the United States from 2004 to 2015 and implications for screening","volume":"74","author":"Dansey","year":"2021","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib7","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1053\/j.semvascsurg.2012.09.003","article-title":"Moving into the paravisceral aorta using fenestrated and branched endografts","volume":"25","author":"Farber","year":"2012","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib8","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.jvs.2018.11.021","article-title":"The state of complex endovascular abdominal aortic aneurysm repairs in the Vascular Quality Initiative","volume":"70","author":"O\u2019Donnell","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib9","doi-asserted-by":"crossref","first-page":"1670","DOI":"10.1016\/j.jvs.2018.08.192","article-title":"Fenestrated endovascular aneurysm repair is associated with lower perioperative morbidity and mortality compared with open repair for complex abdominal aortic aneurysms","volume":"69","author":"Varkevisser","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib10","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1016\/j.jvs.2017.10.055","article-title":"Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices","volume":"67","author":"Dossabhoy","year":"2018","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib11","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1053\/j.semvascsurg.2021.07.001","article-title":"Physician-modified endografts for urgent and emergent aortic pathology","volume":"34","author":"Kimball","year":"2021","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib12","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1016\/j.jvs.2012.02.011","article-title":"Physician-modified endovascular grafts for the treatment of elective, symptomatic, or ruptured juxtarenal aortic aneurysms","volume":"56","author":"Starnes","year":"2012","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib13","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1097\/SLA.0000000000003094","article-title":"Open versus fenestrated endovascular repair of complex abdominal aortic aneurysms","volume":"271","author":"O\u2019Donnell","year":"2020","journal-title":"Ann Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib14","doi-asserted-by":"crossref","first-page":"1690","DOI":"10.1016\/j.jvs.2017.09.046","article-title":"National trends in open surgical, endovascular, and branched-fenestrated endovascular aortic aneurysm repair in Medicare patients","volume":"67","author":"Suckow","year":"2018","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib15","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1016\/j.jvs.2024.01.216","article-title":"National trends in utilization of surgeon modified grafts for complex and thoracoabdominal aortic aneurysms","volume":"79","author":"O\u2019Donnell","year":"2024","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib16","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1016\/j.jvir.2013.07.016","article-title":"Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion","volume":"24","author":"Tacher","year":"2013","journal-title":"J\u00a0Vasc Interv Radiol JVIR"},{"key":"10.1016\/j.jvs.2024.07.108_bib17","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.jvs.2015.03.041","article-title":"A\u00a0novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions","volume":"62","author":"Stangenberg","year":"2015","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib18","first-page":"3167","article-title":"A\u00a0state-of-the-art review of intra-operative imaging modalities used to quality assure endovascular aneurysm repair","volume":"12","author":"Bachrati","year":"2023","journal-title":"J\u00a0Clin Med"},{"key":"10.1016\/j.jvs.2024.07.108_bib19","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1177\/1526602821996725","article-title":"Impact of hybrid operating rooms on long-term clinical outcomes following fenestrated and branched endovascular aortic repair","volume":"28","author":"Tinelli","year":"2021","journal-title":"J\u00a0Endovasc Ther Off J Int Soc Endovasc Spec"},{"key":"10.1016\/j.jvs.2024.07.108_bib20","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.jvs.2014.07.097","article-title":"Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair","volume":"61","author":"McNally","year":"2015","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib21","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1053\/j.semvascsurg.2021.10.001","article-title":"Fiber Optic RealShape technology in endovascular surgery","volume":"34","author":"Finnesgard","year":"2021","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib22","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.jvs.2022.11.041","article-title":"Initial single-center experience using Fiber Optic RealShape guidance in complex endovascular aortic repair","volume":"77","author":"Finnesgard","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib23","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.jvs.2022.08.002","article-title":"Endovascular navigation with fiber optic RealShape technology","volume":"77","author":"Panuccio","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib24","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.jvs.2023.11.002","article-title":"The effect of Fiber Optic RealShape technology on the reduction of radiation during complex endovascular surgery","volume":"79","author":"Sanders","year":"2024","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib25","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.ejvs.2021.07.003","article-title":"Fenestrated-branch endovascular repair after prior abdominal aortic aneurysm repair","volume":"62","author":"Juszczak","year":"2021","journal-title":"Eur J Vasc Endovasc Surg Off J Eur Soc Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib26","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ejvs.2013.03.028","article-title":"Fenestrated stent-grafts for salvage of prior endovascular abdominal aortic aneurysm repair","volume":"46","author":"Katsargyris","year":"2013","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib27","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/j.jvs.2024.01.002","article-title":"Reinterventions and sac dynamics after fenestrated endovascular aortic repair with physician-modified endografts for index aneurysm repair and following proximal failure of prior endovascular aortic repair","volume":"79","author":"Sanders","year":"2024","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib28","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jvs.2023.04.001","article-title":"Outcomes of fenestrated-branched endovascular aortic repair in patients with or without prior history of abdominal endovascular or open surgical repair","volume":"78","author":"Vacirca","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib29","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.jvs.2016.07.123","article-title":"Midterm results from a physician-sponsored investigational device exemption clinical trial evaluating physician-modified endovascular grafts for the treatment of juxtarenal aortic aneurysms","volume":"65","author":"Starnes","year":"2017","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib30","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jvs.2022.09.019","article-title":"Five-year outcomes of physician-modified endografts for repair of complex abdominal and thoracoabdominal aortic aneurysms","volume":"77","author":"Chait","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib31","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1016\/j.jvs.2022.12.061","article-title":"Reinterventions after physician-modified endovascular grafts for treatment of juxtarenal aortic aneurysms are non-detrimental to long-term survival","volume":"77","author":"Tachida","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib32","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jvs.2018.05.216","article-title":"Risk of spinal cord ischemia after fenestrated or branched endovascular repair of complex aortic aneurysms","volume":"69","author":"Spanos","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib33","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.jvs.2020.05.070","article-title":"Risk factors for spinal cord injury and complications of cerebrospinal fluid drainage in patients undergoing fenestrated and branched endovascular aneurysm repair","volume":"73","author":"Kitpanit","year":"2021","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib34","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.jvs.2023.06.002","article-title":"Spinal cord ischemia rates and prophylactic spinal drainage in patients treated with fenestrated\/branched endovascular repair for thoracoabdominal aneurysms","volume":"78","author":"Locatelli","year":"2023","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib35","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.asjsur.2022.03.022","article-title":"Preoperative predictive factors for type II endoleak: trying to define high-risk patients","volume":"46","author":"Su\u00e1rez Gonz\u00e1lez","year":"2023","journal-title":"Asian J Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib36","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.avsg.2017.12.014","article-title":"The influence of 4 or more patent lumbar arteries on persistent type II endoleak and sac expansion after endovascular aneurysm repair","volume":"50","author":"Seike","year":"2018","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib37","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1583\/10-3116.1","article-title":"Predictive factors for the development of type II endoleaks","volume":"18","author":"Marchiori","year":"2011","journal-title":"J\u00a0Endovasc Ther Off J Int Soc Endovasc Spec"},{"key":"10.1016\/j.jvs.2024.07.108_bib38","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jvs.2017.10.044","article-title":"The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm","volume":"67","author":"Chaikof","year":"2018","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib39","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jvs.2016.11.043","article-title":"Comparison of outcomes for double fenestrated endovascular aneurysm repair versus triple or quadruple fenestrated endovascular aneurysm repair in the treatment of complex abdominal aortic aneurysms","volume":"66","author":"Katsargyris","year":"2017","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib40","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.jvs.2016.04.049","article-title":"Evaluation of the learning curve for fenestrated endovascular aneurysm repair","volume":"64","author":"Starnes","year":"2016","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvs.2024.07.108_bib41","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.jvs.2018.09.066","article-title":"Select type I and type III endoleaks at the completion of fenestrated endovascular aneurysm repair resolve spontaneously","volume":"70","author":"Swerdlow","year":"2019","journal-title":"J\u00a0Vasc Surg"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521424017804?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521424017804?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T06:10:35Z","timestamp":1733897435000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521424017804"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["S0741521424017804"],"URL":"https:\/\/doi.org\/10.1016\/j.jvs.2024.07.108","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Ten years of physician-modified endografts","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvs.2024.07.108","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.jvs.2024.08.029","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 by the Society for Vascular Surgery. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}