{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T11:56:37Z","timestamp":1791892597706,"version":"4.3.4"},"reference-count":22,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100011949","name":"Abbott Vascular","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011949","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvascsurg.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.jvs.2026.07.008","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T23:25:56Z","timestamp":1784071556000},"page":"1223-1231.e8","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Open- versus closed-cell stents in transfemoral carotid artery stenting for carotid bifurcation disease: a target trial emulation"],"prefix":"10.1016","volume":"84","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-0857-831X","authenticated-orcid":false,"given":"Zunwei","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaofei","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyi","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yujie","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yitong","family":"Ling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvs.2026.07.008_bib1","doi-asserted-by":"crossref","first-page":"e364","DOI":"10.1161\/STR.0000000000000375","article-title":"2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American Heart Association\/American Stroke Association","volume":"52","author":"Kleindorfer","year":"2021","journal-title":"Stroke"},{"key":"10.1016\/j.jvs.2026.07.008_bib2","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/S1474-4422(25)00106-1","article-title":"Carotid revascularisation for carotid stenosis","volume":"24","author":"Ho","year":"2025","journal-title":"Lancet Neurol"},{"key":"10.1016\/j.jvs.2026.07.008_bib3","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ejvs.2022.04.011","article-title":"Editor's choice\u2013European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on the management of atherosclerotic carotid and vertebral artery disease","volume":"65","author":"Naylor","year":"2023","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib4","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jacc.2022.05.007","article-title":"Carotid artery stenting: JACC state-of-the-art review","volume":"80","author":"White","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jvs.2026.07.008_bib5","doi-asserted-by":"crossref","first-page":"2534","DOI":"10.1161\/STROKEAHA.123.043117","article-title":"Impact of carotid stent design on embolic filter debris load during carotid artery stenting","volume":"54","author":"Squizzato","year":"2023","journal-title":"Stroke"},{"key":"10.1016\/j.jvs.2026.07.008_bib6","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1053\/j.semvascsurg.2025.11.002","article-title":"Types of carotid stents and their associated strengths and limitations","volume":"39","author":"Dubosq-Lebaz","year":"2026","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib7","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jvs.2025.02.025","article-title":"Carotid artery stenting with open vs closed stent cell configurations in the CREST-2 Registry","volume":"82","author":"Lal","year":"2025","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib8","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1136\/neurintsurg-2017-013622","article-title":"Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data","volume":"10","author":"Wodarg","year":"2018","journal-title":"J Neurointerv Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib9","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.jvs.2011.05.013","article-title":"Randomized clinical trial of open-cell vs closed-cell stents for carotid stenting and effects of stent design on cerebral embolization","volume":"54","author":"Timaran","year":"2011","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib10","doi-asserted-by":"crossref","first-page":"642","DOI":"10.3171\/2013.5.JNS1331","article-title":"Incidence of embolism associated with carotid artery stenting: open-cell versus closed-cell stents","volume":"119","author":"Park","year":"2013","journal-title":"J Neurosurg"},{"key":"10.1016\/j.jvs.2026.07.008_bib11","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1136\/jnis-2025-023058","article-title":"Clinical outcomes of carotid artery stenting with open- versus closed-cell stents","volume":"18","author":"Zhang","year":"2026","journal-title":"J Neurointerv Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib12","doi-asserted-by":"crossref","first-page":"3013","DOI":"10.1161\/STROKEAHA.118.024076","article-title":"Stent design, restenosis and recurrent stroke after carotid artery stenting in the International Carotid Stenting Study","volume":"50","author":"M\u00fcller","year":"2019","journal-title":"Stroke"},{"key":"10.1016\/j.jvs.2026.07.008_bib13","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/S1474-4422(18)30195-9","article-title":"Restenosis and risk of stroke after stenting or endarterectomy for symptomatic carotid stenosis in the International Carotid Stenting Study (ICSS): secondary analysis of a randomised trial","volume":"17","author":"Bonati","year":"2018","journal-title":"Lancet Neurol"},{"key":"10.1016\/j.jvs.2026.07.008_bib14","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.jvs.2025.03.199","article-title":"Comparison of restenosis and reintervention rates in closed cell stents compared to open cell stents after carotid artery stenting","volume":"82","author":"Polania-Sandoval","year":"2025","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib15","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/S0140-6736(07)61602-X","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies","volume":"370","author":"von Elm","year":"2007","journal-title":"Lancet"},{"key":"10.1016\/j.jvs.2026.07.008_bib16","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1056\/NEJM199108153250701","article-title":"Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis","volume":"325","author":"Barnett","year":"1991","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jvs.2026.07.008_bib17","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1177\/1526602818783505","article-title":"Effect of open- vs closed-cell stent design on periprocedural outcomes and restenosis after carotid artery stenting: a systematic review and comprehensive meta-analysis","volume":"25","author":"Texakalidis","year":"2018","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvs.2026.07.008_bib18","doi-asserted-by":"crossref","first-page":"1639","DOI":"10.1016\/j.jvs.2020.08.155","article-title":"Comparison of open- and closed-cell stent design outcomes after carotid artery stenting in the Vascular Quality Initiative","volume":"73","author":"Faateh","year":"2021","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib19","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/j.jvs.2008.10.016","article-title":"Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting","volume":"49","author":"Pierce","year":"2009","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvs.2026.07.008_bib20","doi-asserted-by":"crossref","first-page":"E96","DOI":"10.1111\/aor.12046","article-title":"A computational study of the hemodynamic impact of open- versus closed-cell stent design in carotid artery stenting","volume":"37","author":"De Santis","year":"2013","journal-title":"Artif Organs"},{"key":"10.1016\/j.jvs.2026.07.008_bib21","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1253\/circj.CJ-18-1152","article-title":"Carotid geometry as a predictor of in-stent Neointimal hyperplasia - a computational fluid dynamics study","volume":"83","author":"Yao","year":"2019","journal-title":"Circ J"},{"key":"10.1016\/j.jvs.2026.07.008_bib22","doi-asserted-by":"crossref","first-page":"2921","DOI":"10.1161\/STROKEAHA.123.035675","article-title":"Symptomatic nonstenotic carotids: a topical review","volume":"55","author":"Savastano","year":"2024","journal-title":"Stroke"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521426014382?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521426014382?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T11:01:18Z","timestamp":1791889278000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521426014382"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["S0741521426014382"],"URL":"https:\/\/doi.org\/10.1016\/j.jvs.2026.07.008","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Open- versus closed-cell stents in transfemoral carotid artery stenting for carotid bifurcation disease: a target trial emulation","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvs.2026.07.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Society for Vascular Surgery. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}