{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T13:26:16Z","timestamp":1775913976111,"version":"3.50.1"},"reference-count":27,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T00:00:00Z","timestamp":1682035200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010479","name":"Cook Medical","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100010479","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100020453","name":"W. L. Gore and Associates","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020453","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvascsurgcases.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1016\/j.jvscit.2023.101200","type":"journal-article","created":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T21:37:00Z","timestamp":1682631420000},"page":"101200","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Hybrid repair strategies for acute type B aortic dissection complicating prior standard and complex endovascular aortic repair"],"prefix":"10.1016","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4755-2596","authenticated-orcid":false,"given":"Jesse","family":"Chait","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernardo C.","family":"Mendes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lily E.","family":"Johnston","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fahad","family":"Shuja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gustavo S.","family":"Oderich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manju","family":"Kalra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvscit.2023.101200_bib1","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.ejvssr.2019.07.004","article-title":"Acute type B aortic dissection One Month after fenestrated EVAR Procedure","volume":"44","author":"Czaplicki","year":"2019","journal-title":"EJVES Short Rep"},{"key":"10.1016\/j.jvscit.2023.101200_bib2","first-page":"412708","article-title":"Aortic dissection occurring 18 months after successful endovascular repair in an anatomically difficult case of abdominal aortic aneurysm","volume":"2013","author":"Yamamoto","year":"2013","journal-title":"Case Rep Vasc Med"},{"key":"10.1016\/j.jvscit.2023.101200_bib3","doi-asserted-by":"crossref","first-page":"229.e7","DOI":"10.1016\/j.avsg.2015.11.022","article-title":"Type B aortic dissection with abdominal aortic aneurysm rupture 1year after endovascular repair of abdominal aortic aneurysm","volume":"33","author":"Daniel","year":"2016","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib4","doi-asserted-by":"crossref","first-page":"308","DOI":"10.3400\/avd.cr.19-00142","article-title":"A\u00a0case of collapsed stent graft, severe lower limb ischemia, and ruptured abdominal aortic aneurysm due to type B acute aortic dissection 3 years after endovascular aneurysm repair","volume":"13","author":"Motoji","year":"2020","journal-title":"Ann Vasc Dis"},{"key":"10.1016\/j.jvscit.2023.101200_bib5","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.jvs.2019.01.089","article-title":"Five-year results from the study of thoracic aortic Type B dissection using endoluminal repair (STABLE I) study of endovascular treatment of complicated type B aortic dissection using a composite device design","volume":"70","author":"Lombardi","year":"2019","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib6","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jvs.2012.01.013","article-title":"Aortic banding and endovascular aneurysm repair in a case of juxtarenal aortic aneurysm with unsuitable infrarenal neck","volume":"65","author":"Scarcello","year":"2012","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib7","doi-asserted-by":"crossref","first-page":"317.e5","DOI":"10.1016\/j.avsg.2018.01.078","article-title":"Rupture after previous endovascular aneurysm repair due to type IA endoleak: complete endograft preservation is feasible with proximal suturing, aortic neck banding, and sac Plication","volume":"49","author":"Karkos","year":"2018","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib8","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1007\/s11748-018-1016-9","article-title":"Descending aortic banding for re-rupture of retrograde aortic dissection after emergency thoracic endovascular aortic repair","volume":"68","author":"Hattori","year":"2020","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib9","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.avsg.2019.04.025","article-title":"Aortic banding to treat Simultaneously a type Ia endoleak and aortic neck rupture during endovascular abdominal aortic aneurysm repair","volume":"61","author":"Moulakakis","year":"2019","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib10","first-page":"799","article-title":"Long-term results of aortic banding for Complex infrarenal neck anatomy and type I endoleak after endovascular abdominal aortic aneurysm repair","volume":"39","author":"Krajcer","year":"2012","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.jvscit.2023.101200_bib11","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/S0741-5214(03)00931-5","article-title":"Aortic dissection in the setting of an infrarenal endoprosthesis: a fatal combination","volume":"38","author":"Haulon","year":"2003","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib12","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.jvs.2009.03.060","article-title":"Type B aortic dissection after endovascular abdominal aortic aneurysm repair causing endograft collapse and severe malperfusion","volume":"50","author":"Iyer","year":"2009","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib13","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1583\/09-2891.1","article-title":"Abdominal stent-graft collapse due to progression of a Stanford type B dissection","volume":"16","author":"van Keulen","year":"2009","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvscit.2023.101200_bib14","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1583\/13-4595L.1","article-title":"Acute type B dissection complicated by infrarenal aortic stent-graft collapse with Spontaneous Re-expansion","volume":"21","author":"Vainas","year":"2014","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvscit.2023.101200_bib15","doi-asserted-by":"crossref","first-page":"1931.e9","DOI":"10.1016\/j.avsg.2014.06.067","article-title":"Abdominal aortic endograft collapse due to false lumen radial force of an acute type B aortic dissection","volume":"28","author":"Psacharopulo","year":"2014","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib16","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1186\/s40792-015-0096-3","article-title":"Emergency thoracic aortic stent grafting for acute complicated type B aortic dissection after a previous abdominal endovascular aneurysm repair","volume":"1","author":"Yoshiga","year":"2015","journal-title":"Surg Case Rep"},{"key":"10.1016\/j.jvscit.2023.101200_bib17","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1093\/ejcts\/ezx195","article-title":"Collapsed stent graft and severe malperfusion 2 years after endovascular aortic repair","volume":"52","author":"Goto","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib18","doi-asserted-by":"crossref","first-page":"206.e1","DOI":"10.1016\/j.avsg.2017.07.024","article-title":"Acute type B dissection causing collapse of EVAR endograft and iliac limb occlusion","volume":"46","author":"Itoga","year":"2018","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib19","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1177\/1538574418819540","article-title":"Fatal Complications of new-onset complicated type B aortic dissection after endovascular abdominal aortic aneurysm repair: report of 2 cases and literature review","volume":"53","author":"Nomura","year":"2019","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib20","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1177\/1538574419840873","article-title":"Rare case of acute type B dissection causing complete collapse of EVAR stent","volume":"53","author":"Ostapenko","year":"2019","journal-title":"Vasc Endovascular Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib21","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.jvscit.2022.02.010","article-title":"Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: a case report and review of the literature","volume":"8","author":"Cooke","year":"2022","journal-title":"J\u00a0Vasc Surg Cases Innov Tech"},{"key":"10.1016\/j.jvscit.2023.101200_bib22","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1583\/06-1923.1","article-title":"Provisional extension to Induce complete attachment after stent-graft placement in type B aortic dissection: the PETTICOAT Concept","volume":"13","author":"Nienaber","year":"2006","journal-title":"J\u00a0Endovasc Ther"},{"key":"10.1016\/j.jvscit.2023.101200_bib23","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/j.jvs.2019.11.013","article-title":"Society for Vascular Surgery (SVS) and Society of thoracic Surgeons (STS) reporting standards for type B aortic dissections","volume":"71","author":"Lombardi","year":"2020","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib24","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.jvs.2020.05.076","article-title":"Society for Vascular Surgery clinical practice guidelines of thoracic endovascular aortic repair for descending thoracic aortic aneurysms","volume":"73","author":"Upchurch","year":"2021","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib25","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.jvs.2013.07.007","article-title":"Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endografting","volume":"59","author":"Eagleton","year":"2014","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib26","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.jvs.2022.05.014","article-title":"Outcomes of endovascular repair of aortic aneurysms with the GORE thoracic branch endoprosthesis for left subclavian artery preservation","volume":"76","author":"Dake","year":"2022","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvscit.2023.101200_bib27","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.jvir.2020.02.025","article-title":"In situ laser stent graft fenestration of the left subclavian artery during thoracic endovascular repair of type B aortic dissection with limited proximal landing zones: 5-year outcomes","volume":"31","author":"Zhao","year":"2020","journal-title":"J\u00a0Vasc Interv Radiol"}],"container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428723001090?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428723001090?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T06:44:01Z","timestamp":1762843441000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468428723001090"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,6]]}},"alternative-id":["S2468428723001090"],"URL":"https:\/\/doi.org\/10.1016\/j.jvscit.2023.101200","relation":{},"ISSN":["2468-4287"],"issn-type":[{"value":"2468-4287","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Hybrid repair strategies for acute type B aortic dissection complicating prior standard and complex endovascular aortic repair","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery Cases, Innovations and Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvscit.2023.101200","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Inc. on behalf of Society for Vascular Surgery.","name":"copyright","label":"Copyright"}],"article-number":"101200"}}