{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:14:08Z","timestamp":1788898448581,"version":"build-2803163510"},"reference-count":15,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T00:00:00Z","timestamp":1759449600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvascsurgcases.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.jvscit.2025.102007","type":"journal-article","created":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T09:29:53Z","timestamp":1760002193000},"page":"102007","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["A modified squid capture technique for improved laser position during in situ fenestration"],"prefix":"10.1016","volume":"12","author":[{"given":"Matthew S.","family":"Harris","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantinos C.","family":"Karabetsos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert A.","family":"Larson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco C.","family":"Albuqerque","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel H.","family":"Newton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvscit.2025.102007_bib1","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.jtcvs.2011.02.050","article-title":"Thoracic endovascular aortic repair: evolution of therapy, patterns of use, and results in a 10-year experience","volume":"142","author":"Desai","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib2","author":"Reynolds"},{"key":"10.1016\/j.jvscit.2025.102007_bib3","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1053\/j.semvascsurg.2009.07.007","article-title":"Management of the left subclavian artery during TEVAR","volume":"22","author":"Feezor","year":"2009","journal-title":"Semin Vasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib4","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.athoracsur.2008.08.036","article-title":"Endovascular aortic arch repair after aortic arch de-branching","volume":"87","author":"Weigang","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib5","doi-asserted-by":"crossref","first-page":"5567","DOI":"10.1111\/jocs.17174","article-title":"Hybrid off-pump debranching and thoracic endovascular arch repair in a high-risk surgical patient","volume":"37","author":"Dagher","year":"2022","journal-title":"J Card Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib6","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.avsg.2016.12.003","article-title":"Endovascular management of proximal fixation loss using parallel stent grafting techniques to preserve visceral flow","volume":"42","author":"Tanious","year":"2017","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib7","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1016\/j.jvs.2019.04.461","article-title":"Anatomic suitability for \u201coff-the-shelf\u201d thoracic single side-branched endograft in patients with type B aortic dissection","volume":"70","author":"Magee","year":"2019","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib8","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/j.jvs.2013.04.045","article-title":"In situ laser fenestration during emergent thoracic endovascular aortic repair is an effective method for left subclavian artery revascularization","volume":"58","author":"Redlinger","year":"2013","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib9","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.ejvs.2016.06.005","article-title":"Editor\u2019s choice - Management of descending thoracic Aorta Diseases: clinical practice guidelines of the European Society for Vascular Surgery (ESVS)","volume":"53","author":"Riambau","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib10","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.ejvs.2016.10.025","article-title":"Editor\u2019s choice - Incidence of stroke following thoracic endovascular aortic repair for descending aortic aneurysm: a systematic review of the literature with meta-analysis","volume":"53","author":"Von Allmen","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.jvscit.2025.102007_bib11","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1177\/15266028221119315","article-title":"In situ laser fenestration technique: bench testing of aortic endograft to guide clinical practice","volume":"31","author":"Grima","year":"2024","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvscit.2025.102007_bib12","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1007\/s00270-014-0933-y","article-title":"\u201cSquid-Capture\u201d modified in situ stent\u2013graft fenestration technique for aortic arch aneurysm repair","volume":"37","author":"Hongo","year":"2014","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvscit.2025.102007_bib13","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1177\/15266028211007475","article-title":"Gimme\u2019 the loop: modifications to the squid-capture technique for laser-fenestrated thoracic endografting","volume":"28","author":"Mulorz","year":"2021","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvscit.2025.102007_bib14","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1177\/15266028211067737","article-title":"A system for accurate deployment of unconstrained triple-fenestrated aortic arch endografts","volume":"29","author":"Joseph","year":"2022","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.jvscit.2025.102007_bib15","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1016\/j.jvs.2020.01.072","article-title":"Early and midterm outcomes of in situ laser fenestration during thoracic endovascular aortic repair for acute and subacute aortic arch diseases and analysis of its complications","volume":"72","author":"Li","year":"2020","journal-title":"J Vasc Surg"}],"container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428725002898?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428725002898?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:33:12Z","timestamp":1769128392000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468428725002898"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["S2468428725002898"],"URL":"https:\/\/doi.org\/10.1016\/j.jvscit.2025.102007","relation":{},"ISSN":["2468-4287"],"issn-type":[{"value":"2468-4287","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A modified squid capture technique for improved laser position during in situ fenestration","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery Cases, Innovations and Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvscit.2025.102007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of Society for Vascular Surgery.","name":"copyright","label":"Copyright"}],"article-number":"102007"}}