{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T16:18:09Z","timestamp":1783441089380,"version":"3.54.6"},"reference-count":13,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jvascsurgcases.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1016\/j.jvscit.2026.102228","type":"journal-article","created":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T17:11:49Z","timestamp":1773335509000},"page":"102228","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Percutaneous salvage of a failed 14F suture-mediated femoral closure using dual collagen-mediated vascular closure devices"],"prefix":"10.1016","volume":"12","author":[{"given":"Estefania","family":"Rivera-Pedraza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis A.","family":"Santiago-Sulsona","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5385-2221","authenticated-orcid":false,"given":"Jos\u00e9 L.","family":"Ortiz-Fullana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael","family":"Santini-Domingue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvscit.2026.102228_bib1","doi-asserted-by":"crossref","DOI":"10.1503\/cmaj.180976","article-title":"Transcatheter aortic valve implantation for severe aortic stenosis","volume":"191","author":"Garg","year":"2019","journal-title":"CMAJ"},{"key":"10.1016\/j.jvscit.2026.102228_bib2","doi-asserted-by":"crossref","first-page":"2120","DOI":"10.1016\/j.jvs.2020.03.035","article-title":"Incidence, predictors, impact, and treatment of vascular complications after transcatheter aortic valve implantation in a modern prospective cohort under real conditions","volume":"72","author":"Langouet","year":"2020","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jvscit.2026.102228_bib3","first-page":"1490","article-title":"Vascular complications in patients undergoing transcatheter aortic valve replacement with contemporary devices","volume":"41","author":"Cepas-Guill\u00e9n","year":"2025","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.jvscit.2026.102228_bib4","first-page":"474","article-title":"Access site management after aortic valvuloplasty using a suture mediated closure device: clinical experience in 4 cases","volume":"12","author":"Marchant","year":"2000","journal-title":"J Invasive Cardiol"},{"key":"10.1016\/j.jvscit.2026.102228_bib5","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1111\/j.1540-8183.2008.00402.x","article-title":"A novel technique for 14 French arteriotomy closure after percutaneous aortic valvuloplasty using two Mynx closure devices","volume":"22","author":"Korngold","year":"2009","journal-title":"J Interv Cardiol"},{"key":"10.1016\/j.jvscit.2026.102228_bib6","article-title":"Femoral artery closure devices vs manual compression during cardiac catheterization and percutaneous coronary intervention","volume":"1","author":"Kreutz","year":"2022","journal-title":"J Soc Cardiovasc Angiogr Interv"},{"key":"10.1016\/j.jvscit.2026.102228_bib7","first-page":"E604","article-title":"Secondary femoral access hemostasis during transcatheter aortic valve replacement: impact of vascular closure devices","volume":"33","author":"Junquera","year":"2021","journal-title":"J Invasive Cardiol"},{"key":"10.1016\/j.jvscit.2026.102228_bib8","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1055\/s-0039-1683898","article-title":"Factors associated with wound complications after open femoral artery exposure for elective endovascular abdominal aortic aneurysm repair","volume":"28","author":"Trinidad","year":"2019","journal-title":"Int J Angiol"},{"key":"10.1016\/j.jvscit.2026.102228_bib9","first-page":"627","article-title":"The safety and efficacy of an extravascular, water-soluble sealant for vascular closure: initial clinical results for Mynx","volume":"70","author":"Scheinert","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jvscit.2026.102228_bib10","first-page":"23","article-title":"The Mynx\u2122 vascular closure device","volume":"7","author":"Ansel","year":"2008","journal-title":"Endovasc Today"},{"key":"10.1016\/j.jvscit.2026.102228_bib11","first-page":"27","article-title":"The Mynx\u00ae vascular closure device: adopting extravascular closure technology in the catheterization lab","volume":"8","author":"Kabour","year":"2009","journal-title":"Endovasc Today"},{"key":"10.1016\/j.jvscit.2026.102228_bib12","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2022.832242","article-title":"Real-world experience with a large bore vascular closure device during TAVI procedure: features and predictors of access-site vascular complications","volume":"9","author":"Masiero","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"10.1016\/j.jvscit.2026.102228_bib13","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.cjco.2022.03.006","article-title":"Iliofemoral tortuosity increases the risk of access-site-related complications after aortic valve implantation and plug-based access-site closure","volume":"4","author":"Lux","year":"2022","journal-title":"CJC Open"}],"container-title":["Journal of Vascular Surgery Cases, Innovations and Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428726001127?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468428726001127?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T15:25:01Z","timestamp":1783437901000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468428726001127"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["S2468428726001127"],"URL":"https:\/\/doi.org\/10.1016\/j.jvscit.2026.102228","relation":{},"ISSN":["2468-4287"],"issn-type":[{"value":"2468-4287","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Percutaneous salvage of a failed 14F suture-mediated femoral closure using dual collagen-mediated vascular closure devices","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery Cases, Innovations and Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvscit.2026.102228","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc. on behalf of Society for Vascular Surgery.","name":"copyright","label":"Copyright"}],"article-number":"102228"}}