{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:22:48Z","timestamp":1760955768340},"reference-count":16,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","jvsvenous.com","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Vascular Surgery: Venous and Lymphatic Disorders"],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1016\/j.jvsv.2017.09.006","type":"journal-article","created":{"date-parts":[[2017,12,9]],"date-time":"2017-12-09T05:37:28Z","timestamp":1512797848000},"page":"163-172","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Complications and retrieval characteristics of Celect Platinum inferior vena cava filters"],"prefix":"10.1016","volume":"6","author":[{"given":"Brian E.","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard J.","family":"Van Allan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc L.","family":"Friedman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. Gabriel","family":"Lipshutz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jvsv.2017.09.006_bib1","first-page":"1499","article-title":"Quality improvement guidelines for the performance of inferior vena cava filter placement for the prevention of pulmonary embolism","volume":"22","author":"Caplin","year":"2011","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib2","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.amjmed.2011.02.021","article-title":"Increasing use of vena cava filters for prevention of pulmonary embolism","volume":"124","author":"Stein","year":"2011","journal-title":"Am J Med"},{"key":"10.1016\/j.jvsv.2017.09.006_bib4","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1016\/j.jvir.2013.07.023","article-title":"Complications of Celect, Gunther Tulip, and Greenfield inferior vena cava filters on CT follow-up: a single-institution experience","volume":"24","author":"McLoney","year":"2013","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib5","doi-asserted-by":"crossref","first-page":"643","DOI":"10.2214\/AJR.13.11097","article-title":"Penetration of Celect inferior vena cava filters: retrospective review of CT scans in 265 patients","volume":"202","author":"Zhou","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib6","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/s00270-011-0151-9","article-title":"Perforation of the IVC: rule rather than exception after longer indwelling times for the Gunther Tulip and Celect retrievable filters","volume":"35","author":"Durack","year":"2012","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib7","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1016\/j.jvir.2012.08.016","article-title":"Retrospective review of 120 Celect inferior vena cava filter retrievals: experience at a single institution","volume":"23","author":"Zhou","year":"2012","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib8","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jvir.2014.09.010","article-title":"Strut penetration: local complications, breakthrough pulmonary embolism, and retrieval failure in patients with Celect vena cava filters","volume":"26","author":"Bos","year":"2015","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib9","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1016\/j.jvir.2009.05.033","article-title":"Safety and effectiveness of the Celect inferior vena cava filter: preliminary results","volume":"20","author":"Sangwaiya","year":"2009","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib10","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1055\/s-0031-1278355","article-title":"Symptomatic inferior vena cava perforation by a retrievable filter: report of two cases and a literature review","volume":"18","author":"Franz","year":"2009","journal-title":"Int J Angiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib11","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.jvs.2010.04.065","article-title":"Late erosion of a prophylactic Celect IVC filter into the aorta, right renal artery, and duodenal wall","volume":"52","author":"Becher","year":"2010","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvsv.2017.09.006_bib12","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1016\/j.jvir.2013.07.019","article-title":"Fracture and migration of Celect IVC filters: a retrospective review of 741 consecutive implantations","volume":"24","author":"Wang","year":"2013","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib13","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1016\/j.jvir.2009.07.038","article-title":"Short- and long-term retrievability of the Celect vena cava filter: results from a multi-institutional registry","volume":"20","author":"Lyon","year":"2009","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib14","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1016\/j.jvir.2007.07.002","article-title":"Loop-snare technique for difficult inferior vena cava filter retrievals","volume":"18","author":"Rubenstein","year":"2007","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib15","doi-asserted-by":"crossref","first-page":"144","DOI":"10.5152\/dir.2016.16022","article-title":"Ten-year experience of retrievable inferior vena cava filters in a tertiary referral center","volume":"23","author":"Tse","year":"2017","journal-title":"Diagn Interv Radiol"},{"key":"10.1016\/j.jvsv.2017.09.006_bib16","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.jvs.2016.02.034","article-title":"Temporary inferior vena cava filter indications, retrieval rates, and follow-up management at a multicenter tertiary care institution","volume":"64","author":"Tao","year":"2016","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.jvsv.2017.09.006_bib17","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1016\/j.jvir.2016.06.028","article-title":"Analysis of the final DENALI trial data: a prospective, multicenter study of the Denali inferior vena cava filter","volume":"27","author":"Stavropoulos","year":"2016","journal-title":"J\u00a0Vasc Interv Radiol"}],"container-title":["Journal of Vascular Surgery: Venous and Lymphatic Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213333X17304468?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213333X17304468?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,8,25]],"date-time":"2018-08-25T10:21:57Z","timestamp":1535192517000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2213333X17304468"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,3]]}},"alternative-id":["S2213333X17304468"],"URL":"https:\/\/doi.org\/10.1016\/j.jvsv.2017.09.006","relation":{},"ISSN":["2213-333X"],"issn-type":[{"value":"2213-333X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Complications and retrieval characteristics of Celect Platinum inferior vena cava filters","name":"articletitle","label":"Article Title"},{"value":"Journal of Vascular Surgery: Venous and Lymphatic Disorders","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jvsv.2017.09.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 by the Society for Vascular Surgery. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}