{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T17:32:19Z","timestamp":1780767139842,"version":"3.54.1"},"reference-count":18,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2017,2,28]],"date-time":"2017-02-28T00:00:00Z","timestamp":1488240000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2017,2,28]],"date-time":"2017-02-28T00:00:00Z","timestamp":1488240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,11,16]],"date-time":"2016-11-16T00:00:00Z","timestamp":1479254400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"E-Da"},{"name":"National Cheng Kung University Co-promotion Research Program","award":["10358"],"award-info":[{"award-number":["10358"]}]},{"name":"School of Medicine, National Cheng Kung University"}],"content-domain":{"domain":["kjms-online.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Kaohsiung J of Med Scie"],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:label\/><jats:p>Transcutaneous electrical nerve stimulators (TENSs) have been proved to be effective in muscle pain management for several decades. However, there is no consensus for the optimal TENS program. Previous research demonstrated that a 100\u2009Hz TENS (L\u2010TENS) provided better analgesia than a conventional TENS (&lt; 5\u2009Hz). However, no research compared a higher\u2010frequency (&gt; 100\u2009Hz) TENS with a 100\u2009Hz TENS. We used a 5000\u2009Hz (5\u2009kHz) frequency TENS (M\u2010TENS) and an L\u2010TENS to compare analgesic effect on a mice skin\/muscle incision retraction model. Three groups of mice were used (sham, L\u2010TENS, and M\u2010TENS) and applied with different TENS programs on Day 4 after the mice skin\/muscle incision retraction model; TENS therapy was continued as 20\u2009min\/d for 3 days. Mice analgesic effects were measured via Von Frey microfilaments with the up\u2013down method. After therapy, mice spinal cord dorsal horn and dorsal root ganglion (DRG) were harvested for cytokine evaluation (tumor necrosis factor\u2010\u03b1 and interleukin\u20101\u03b2) with the Western blotting method. Our data demonstrated that the M\u2010TENS produced better analgesia than the L\u2010TENS. Cytokine in the spinal cord or DRG all expressed lower than that of the sham group. However, there is no difference in both cytokine levels between TENSs of different frequencies in the spinal cord and DRG. We concluded that the M\u2010TENS produced faster and better mechanical analgesia than the L\u2010TENS in the mice skin\/muscle incision retraction model. Those behavior differences were not in accordance with cytokine changes in the spinal cord or DRG.<\/jats:p><\/jats:sec>","DOI":"10.1016\/j.kjms.2017.01.009","type":"journal-article","created":{"date-parts":[[2017,3,1]],"date-time":"2017-03-01T03:16:07Z","timestamp":1488338167000},"page":"165-170","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Transcutaneous electrical nerve stimulator of 5000\u2009Hz frequency provides better analgesia than that of 100\u2009Hz frequency in mice muscle pain model"],"prefix":"10.1002","volume":"33","author":[{"given":"Hung\u2010Tsung","family":"Hsiao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiao\u2010Jung","family":"Chien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya\u2010Chi","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yen\u2010Chin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,2,28]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.1989.11.3.100"},{"key":"e_1_2_6_3_2","first-page":"200","article-title":"Effect of transcutaneous electrical nerve stimulation, cold, and a combination treatment on pain, decreased range of motion, and strength loss associated with delayed onset muscle soreness","volume":"27","author":"Denegar C.R.","year":"1992","journal-title":"J Athl Train"},{"key":"e_1_2_6_4_2","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1007\/BF03018250","article-title":"Transcutaneous electrical nerve stimulation prevents visceral pain in mice","volume":"51","author":"Guevara L\u00f3pez U.","year":"2004","journal-title":"Can J Anaesth"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0304-3959(98)00090-6"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/86.5.698"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pain.2014.06.022"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/572949"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.2147\/JPR.S111035"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-4159.2005.03511.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpain.2009.05.008"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.pain.0000000000000276"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpain.2008.08.008"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.2522\/ptj.20130306"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.3109\/00207459209000531"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pain.2007.05.013"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pain.2009.11.017"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/1440-1681.12536"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jns.2014.09.024"}],"container-title":["The Kaohsiung Journal of Medical Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1607551X16303898?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1607551X16303898?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.kjms.2017.01.009","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.kjms.2017.01.009","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.kjms.2017.01.009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T04:46:52Z","timestamp":1694666812000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1016\/j.kjms.2017.01.009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,28]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["10.1016\/j.kjms.2017.01.009"],"URL":"https:\/\/doi.org\/10.1016\/j.kjms.2017.01.009","archive":["Portico"],"relation":{},"ISSN":["1607-551X","2410-8650"],"issn-type":[{"value":"1607-551X","type":"print"},{"value":"2410-8650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,28]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transcutaneous electrical nerve stimulator of 5000\u00a0Hz frequency provides better analgesia than that of 100\u00a0Hz frequency in mice muscle pain model","name":"articletitle","label":"Article Title"},{"value":"The Kaohsiung Journal of Medical Sciences","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.kjms.2017.01.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017, Kaohsiung Medical University. Published by Elsevier Taiwan LLC.","name":"copyright","label":"Copyright"}]}}