{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T13:20:56Z","timestamp":1792156856788,"version":"4.4.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2008,10,1]],"date-time":"2008-10-01T00:00:00Z","timestamp":1222819200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Knee"],"published-print":{"date-parts":[[2008,10]]},"DOI":"10.1016\/j.knee.2008.05.001","type":"journal-article","created":{"date-parts":[[2008,7,17]],"date-time":"2008-07-17T21:22:25Z","timestamp":1216329745000},"page":"396-402","source":"Crossref","is-referenced-by-count":25,"title":["Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up"],"prefix":"10.1016","volume":"15","author":[{"given":"C.","family":"Trozzi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.L.","family":"Kaptein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.H.","family":"Garling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Shelyakova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Bragonzoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Martelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.knee.2008.05.001_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/17453678909154184","article-title":"Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system","volume":"Suppl 232","author":"Selvik","year":"1989","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.knee.2008.05.001_bib2","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/01.blo.0000224001.95141.fe","article-title":"The history and future of radiostereometric analysis","volume":"448","author":"K\u00e4rrholm","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2008.05.001_bib3","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1302\/0301-620X.77B3.7744919","article-title":"Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses","volume":"77B","author":"Ryd","year":"1995","journal-title":"J Bone Joint Surg [Br]"},{"key":"10.1016\/j.knee.2008.05.001_bib4","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/S0021-9290(01)00028-8","article-title":"Model-based Roentgen stereophotogrammetry of orthopaedic implants","volume":"34","author":"Valstar","year":"2001","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib5","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/S0021-9290(03)00002-2","article-title":"A new model-based RSA method validated using CAD models and models from reversed engineering","volume":"36","author":"Kaptein","year":"2003","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib6","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S0968-0160(03)00070-X","article-title":"In vivo measurement of total knee replacement wear","volume":"11","author":"Kellett","year":"2004","journal-title":"Knee"},{"key":"10.1016\/j.knee.2008.05.001_bib7","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1109\/10.495283","article-title":"Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy","volume":"43","author":"Banks","year":"1996","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.knee.2008.05.001_bib8","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1016\/j.jbiomech.2004.09.018","article-title":"A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem","volume":"38","author":"Kaptein","year":"2005","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib9","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1302\/0301-620X.84B6.11146","article-title":"Roentgen single-plane photogrammetric analysis (RSPA). A new approach to the study of musculoskeletal movement","volume":"84","author":"Yuan","year":"2002","journal-title":"J Bone Joint Surg [Br]"},{"issue":"Suppl 1","key":"10.1016\/j.knee.2008.05.001_bib10","doi-asserted-by":"crossref","first-page":"S129","DOI":"10.1016\/S0021-9290(06)83420-2","article-title":"Accuracy and precision of a model-based RSA technique for measuring implant migration","volume":"39","author":"Hurschler","year":"2006","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib11","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1080\/17453670710014095","article-title":"High-precision measurements of cementless acetabular components using model-based RSA: an experimental study","volume":"78","author":"Baad-Hansen","year":"2007","journal-title":"Acta Orthop"},{"key":"10.1016\/j.knee.2008.05.001_bib12","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/01.blo.0000224010.04551.14","article-title":"Model-based RSA of a femoral hip stem using surface and geometrical shape models","volume":"448","author":"Kaptein","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2008.05.001_bib13","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/BLO.0b013e3181571aa5","article-title":"Clinical validation of model-based RSA for a total knee prosthesis","volume":"464","author":"Kaptein","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2008.05.001_bib14","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1016\/S0021-9290(97)00054-7","article-title":"Error propagation for relative motion determined from marker positions","volume":"30","author":"Yuan","year":"1997","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib15","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1080\/17453670510041574","article-title":"Guidelines for standardization of radiostereometry (RSA) of implants","volume":"76","author":"Valstar","year":"2005","journal-title":"Acta Orthop"},{"issue":"4","key":"10.1016\/j.knee.2008.05.001_bib16","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1243\/0954411041561036","article-title":"Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis","volume":"218","author":"Kaptein","year":"2004","journal-title":"Proc Inst Mech Eng [H]"},{"key":"10.1016\/j.knee.2008.05.001_bib17","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1002\/jor.1100130308","article-title":"Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller\u2013Galante I design","volume":"13","author":"Nilsson","year":"1995","journal-title":"J Orthop Res"},{"key":"10.1016\/j.knee.2008.05.001_bib18","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/0021-9290(93)90098-Y","article-title":"Determining the movements of the skeleton using well-configured markers","volume":"26","author":"S\u00f6derkvist","year":"1993","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2008.05.001_bib19","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/S0924-2716(02)00064-3","article-title":"The use of Roentgen stereophotogrammetry to study micromotion of orthopaedic implants","volume":"56","author":"Valstar","year":"2002","journal-title":"ISPRS J Photogramm Remote Sens"}],"container-title":["The Knee"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016008000811?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016008000811?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,9,13]],"date-time":"2021-09-13T07:19:27Z","timestamp":1631517567000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0968016008000811"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,10]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2008,10]]}},"alternative-id":["S0968016008000811"],"URL":"https:\/\/doi.org\/10.1016\/j.knee.2008.05.001","relation":{},"ISSN":["0968-0160"],"issn-type":[{"value":"0968-0160","type":"print"}],"subject":[],"published":{"date-parts":[[2008,10]]}}}