{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T03:41:27Z","timestamp":1777002087480,"version":"3.51.4"},"reference-count":29,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T00:00:00Z","timestamp":1456790400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","thekneejournal.com","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Knee"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1016\/j.knee.2015.12.008","type":"journal-article","created":{"date-parts":[[2016,1,17]],"date-time":"2016-01-17T05:37:21Z","timestamp":1453009041000},"page":"295-299","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Medial cortical fractures in computer-assisted closing-wedge high tibial osteotomy"],"prefix":"10.1016","volume":"23","author":[{"given":"Dae Kyung","family":"Bae","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheol Hee","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eung Ju","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4440-9791","authenticated-orcid":false,"given":"Sang Jun","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.knee.2015.12.008_bb0005","doi-asserted-by":"crossref","first-page":"61","DOI":"10.5792\/ksrr.2012.24.2.61","article-title":"High tibial osteotomy","volume":"24","author":"Lee","year":"2012","journal-title":"Knee Surg Relat Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0010","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.2106\/00004623-198567070-00025","article-title":"Upper tibial osteotomy for osteoarthritis","volume":"67","author":"Coventry","year":"1985","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.knee.2015.12.008_bb0015","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.arthro.2011.01.008","article-title":"High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute","volume":"27","author":"Schroter","year":"2011","journal-title":"Arthroscopy"},{"key":"10.1016\/j.knee.2015.12.008_bb0020","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/00003086-199110000-00029","article-title":"High tibial osteotomy. Use of an osteotomy jig, rigid fixation, and early motion versus conventional surgical technique and cast immobilization","volume":"271","author":"Hofmann","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0025","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/00003086-200202000-00020","article-title":"Avoidance of medial cortical fracture in high tibial osteotomy: improved technique","volume":"395","author":"Kessler","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0030","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1177\/0363546505275488","article-title":"The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy","volume":"33","author":"Miller","year":"2005","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.knee.2015.12.008_bb0035","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1080\/17453670710015508","article-title":"Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique","volume":"79","author":"van Raaij","year":"2008","journal-title":"Acta Orthop"},{"key":"10.1016\/j.knee.2015.12.008_bb0040","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.arthro.2011.06.034","article-title":"Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture","volume":"28","author":"Takeuchi","year":"2012","journal-title":"Arthroscopy"},{"key":"10.1016\/j.knee.2015.12.008_bb0045","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1302\/0301-620X.91B9.22058","article-title":"Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique","volume":"91","author":"Bae","year":"2009","journal-title":"J Bone Joint Surg (Br)"},{"key":"10.1016\/j.knee.2015.12.008_bb0050","doi-asserted-by":"crossref","first-page":"2273","DOI":"10.1007\/s00264-014-2442-7","article-title":"Degree of axis correction in valgus high tibial osteotomy: proposal of an individualised approach","volume":"38","author":"Feucht","year":"2014","journal-title":"Int Orthop"},{"key":"10.1016\/j.knee.2015.12.008_bb0055","first-page":"167","article-title":"A newly designed miniplate staple for high tibial osteotomy","volume":"56","author":"Bae","year":"1997","journal-title":"Bull Hosp Jt Dis"},{"key":"10.1016\/j.knee.2015.12.008_bb0060","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/JSA.0b013e318172b562","article-title":"Computer-assisted double level osteotomy for severe genu varum","volume":"16","author":"Saragaglia","year":"2008","journal-title":"Sports Med Arthrosc"},{"key":"10.1016\/j.knee.2015.12.008_bb0065","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.1007\/s00167-014-2914-8","article-title":"A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate","volume":"23","author":"Cotic","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"Suppl. 9","key":"10.1016\/j.knee.2015.12.008_bb0070","first-page":"S21","article-title":"Loss of correction after medial opening wedge high tibial osteotomy: a comparison of locking plates without bone grafts and non-locking compression plates with bone grafts","volume":"95","author":"Pornrattanamaneewong","year":"2012","journal-title":"J Med Assoc Thail"},{"key":"10.1016\/j.knee.2015.12.008_bb0075","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1007\/s00167-012-1898-5","article-title":"Change in limb length after high tibial osteotomy using computer-assisted surgery: a comparative study of closed- and open-wedge osteotomies","volume":"21","author":"Bae","year":"2013","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.knee.2015.12.008_bb0080","doi-asserted-by":"crossref","first-page":"1454","DOI":"10.1302\/0301-620X.88B11.17743","article-title":"Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate. A one-year randomised, controlled study","volume":"88","author":"Brouwer","year":"2006","journal-title":"J Bone Joint Surg (Br)"},{"key":"10.1016\/j.knee.2015.12.008_bb0085","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1007\/s00167-006-0074-1","article-title":"High tibial osteotomy with Puddu plate for the treatment of varus gonarthrosis","volume":"14","author":"Asik","year":"2006","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.knee.2015.12.008_bb0090","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1097\/00003086-199201000-00025","article-title":"Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length","volume":"274","author":"Dugdale","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0095","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1177\/036354659202000612","article-title":"The anterior cruciate ligament-deficient knee with varus alignment. An analysis of gait adaptations and dynamic joint loadings","volume":"20","author":"Noyes","year":"1992","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.knee.2015.12.008_bb0100","doi-asserted-by":"crossref","first-page":"332","DOI":"10.2106\/00004623-198769030-00005","article-title":"Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study","volume":"69","author":"Hernigou","year":"1987","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.knee.2015.12.008_bb0105","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1007\/s00264-009-0723-3","article-title":"Stability of medial opening wedge high tibial osteotomy: a failure analysis","volume":"34","author":"Nelissen","year":"2010","journal-title":"Int Orthop"},{"key":"10.1016\/j.knee.2015.12.008_bb0110","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.arthro.2008.12.020","article-title":"Complications after medial opening wedge high tibial osteotomy","volume":"25","author":"Miller","year":"2009","journal-title":"Arthroscopy"},{"key":"10.1016\/j.knee.2015.12.008_bb0115","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1007\/s004020050399","article-title":"Loss of correction after lateral closing wedge high tibial osteotomy\u2014a human cadaver study","volume":"119","author":"Bohler","year":"1999","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.knee.2015.12.008_bb0120","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1007\/s00132-003-0591-2","article-title":"Stability, bone healing and loss of correction after valgus realignment of the tibial head. A roentgen stereometry analysis","volume":"33","author":"Pape","year":"2004","journal-title":"Orthopade"},{"key":"10.1016\/j.knee.2015.12.008_bb0125","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s00402-003-0588-7","article-title":"Complications in high tibial (medial opening wedge) osteotomy","volume":"124","author":"Spahn","year":"2004","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.knee.2015.12.008_bb0130","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1002\/jor.20510","article-title":"Navigated lower limb axis measurements: influence of mechanical weight-bearing simulation","volume":"26","author":"Kendoff","year":"2008","journal-title":"J Orthop Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0135","doi-asserted-by":"crossref","first-page":"49","DOI":"10.5792\/ksrr.2015.27.1.49","article-title":"Coronal alignment of the lower limb and the incidence of constitutional varus knee in Korean females","volume":"27","author":"Song","year":"2015","journal-title":"Knee Surg Relat Res"},{"key":"10.1016\/j.knee.2015.12.008_bb0140","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1177\/0363546514525929","article-title":"Adverse event rates and classifications in medial opening wedge high tibial osteotomy","volume":"42","author":"Martin","year":"2014","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.knee.2015.12.008_bb0145","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1007\/s11999-013-3383-y","article-title":"Medial open wedge high tibial osteotomy: can delayed or nonunion be predicted?","volume":"472","author":"van Houten","year":"2014","journal-title":"Clin Orthop Relat Res"}],"container-title":["The Knee"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S096801601500294X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S096801601500294X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T20:42:11Z","timestamp":1654116131000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S096801601500294X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["S096801601500294X"],"URL":"https:\/\/doi.org\/10.1016\/j.knee.2015.12.008","relation":{},"ISSN":["0968-0160"],"issn-type":[{"value":"0968-0160","type":"print"}],"subject":[],"published":{"date-parts":[[2016,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Medial cortical fractures in computer-assisted closing-wedge high tibial osteotomy","name":"articletitle","label":"Article Title"},{"value":"The Knee","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.knee.2015.12.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}