{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:07:38Z","timestamp":1786993658398,"version":"build-2736575974"},"reference-count":34,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","thekneejournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Knee"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1016\/j.knee.2019.11.017","type":"journal-article","created":{"date-parts":[[2020,1,15]],"date-time":"2020-01-15T17:18:44Z","timestamp":1579108724000},"page":"543-551","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":45,"title":["Comparison of weight-bearing full-length radiographs and computed-tomography-scan-based three-dimensional models in the assessment of knee joint coronal alignment"],"prefix":"10.1016","volume":"27","author":[{"given":"Vicente J.","family":"Le\u00f3n-Mu\u00f1oz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirian","family":"L\u00f3pez-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Mart\u00ednez-Mart\u00ednez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Santonja-Medina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6 Suppl","key":"10.1016\/j.knee.2019.11.017_bb0005","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.arth.2009.04.034","article-title":"Coronal alignment in total knee arthroplasty: just how important is it?","volume":"24","author":"Fang","year":"2009","journal-title":"J Arthroplasty"},{"issue":"8","key":"10.1016\/j.knee.2019.11.017_bb0010","doi-asserted-by":"crossref","first-page":"2393","DOI":"10.1007\/s00167-016-4247-2","article-title":"Alignment in total knee arthroplasty","volume":"24","author":"Becker","year":"2016","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"10","key":"10.1016\/j.knee.2019.11.017_bb0015","doi-asserted-by":"crossref","first-page":"2191","DOI":"10.1007\/s00167-013-2622-9","article-title":"Alignment in total knee arthroplasty, still more questions than answers\u2026","volume":"21","author":"Thienpont","year":"2013","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"12","key":"10.1016\/j.knee.2019.11.017_bb0020","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.2106\/JBJS.I.01398","article-title":"Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements","volume":"92","author":"Parratte","year":"2010","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"10.1016\/j.knee.2019.11.017_bb0025","doi-asserted-by":"crossref","first-page":"472","DOI":"10.2106\/JBJS.16.01587","article-title":"Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow-up at 20 years","volume":"100","author":"Abdel","year":"2018","journal-title":"J Bone Joint Surg Am"},{"issue":"12","key":"10.1016\/j.knee.2019.11.017_bb0030","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1007\/s00402-010-1064-9","article-title":"Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement","volume":"130","author":"Matziolis","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"issue":"17","key":"10.1016\/j.knee.2019.11.017_bb0035","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.2106\/JBJS.J.00772","article-title":"The effect of alignment and BMI on failure of total knee replacement","volume":"93","author":"Ritter","year":"2011","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.knee.2019.11.017_bb0040","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.knee.2011.11.003","article-title":"Effect of tibial component varus on wear in total knee arthroplasty","volume":"19","author":"Srivastava","year":"2012","journal-title":"Knee"},{"issue":"6","key":"10.1016\/j.knee.2019.11.017_bb0045","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.knee.2014.05.001","article-title":"Pre-operative analysis of lower limb coronal alignment \u2013 a comparison of supine MRI versus standing full-length alignment radiographs","volume":"21","author":"Winter","year":"2014","journal-title":"Knee"},{"issue":"4","key":"10.1016\/j.knee.2019.11.017_bb0050","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.knee.2012.07.009","article-title":"The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography","volume":"20","author":"Babazadeh","year":"2013","journal-title":"Knee"},{"issue":"1","key":"10.1016\/j.knee.2019.11.017_bb0055","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.knee.2015.08.008","article-title":"Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan","volume":"23","author":"Boonen","year":"2016","journal-title":"Knee"},{"issue":"2","key":"10.1016\/j.knee.2019.11.017_bb0060","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.knee.2015.11.013","article-title":"Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs","volume":"23","author":"Bowman","year":"2016","journal-title":"Knee"},{"issue":"3","key":"10.1016\/j.knee.2019.11.017_bb0065","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1007\/s00167-013-2687-5","article-title":"The difference between weight-bearing and non-weight-bearing alignment in patient-specific instrumentation planning","volume":"22","author":"Paternostre","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"10.1016\/j.knee.2019.11.017_bb0070","first-page":"401","article-title":"Foot rotational effects on radiographic measures of lower limb alignment","volume":"49","author":"Hunt","year":"2006","journal-title":"Can J Surg"},{"key":"10.1016\/j.knee.2019.11.017_bb0075","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/00003086-198911000-00009","article-title":"Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty","volume":"248","author":"Jiang","year":"1989","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10.1016\/j.knee.2019.11.017_bb0080","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/S0883-5403(06)80042-2","article-title":"Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty","volume":"8","author":"Oswald","year":"1993","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.knee.2019.11.017_bb0085","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1097\/00003086-200002000-00029","article-title":"Does axial limb rotation affect the alignment measurements in deformed limbs?","volume":"371","author":"Swanson","year":"2000","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"10.1016\/j.knee.2019.11.017_bb0090","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1177\/0363546506293024","article-title":"Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weightbearing status and associations with dynamic joint load","volume":"35","author":"Specogna","year":"2007","journal-title":"Am J Sports Med"},{"issue":"1","key":"10.1016\/j.knee.2019.11.017_bb0095","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1186\/s13018-017-0571-6","article-title":"Do small changes in rotation affect measurements of lower extremity limb alignment?","volume":"12","author":"Jamali","year":"2017","journal-title":"J Orthop Surg Res"},{"issue":"9","key":"10.1016\/j.knee.2019.11.017_bb0100","first-page":"1796","article-title":"Frontal plane knee alignment: a call for standardized measurement","volume":"34","author":"Cooke","year":"2007","journal-title":"J Rheumatol"},{"issue":"3","key":"10.1016\/j.knee.2019.11.017_bb0105","doi-asserted-by":"crossref","first-page":"472","DOI":"10.3899\/jrheum.080732","article-title":"Optimizing limb position for measuring knee anatomical axis alignment from standing knee radiographs","volume":"36","author":"Cooke","year":"2009","journal-title":"J Rheumatol"},{"issue":"5","key":"10.1016\/j.knee.2019.11.017_bb0110","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1080\/00016470310017965","article-title":"The whole leg radiograph: standing versus supine for determining axial alignment","volume":"74","author":"Brouwer","year":"2003","journal-title":"Acta Orthop Scand"},{"issue":"11","key":"10.1016\/j.knee.2019.11.017_bb0115","doi-asserted-by":"crossref","first-page":"3569","DOI":"10.1007\/s00167-017-4636-1","article-title":"Measurement of lower limb alignment: there are within-person differences between weight-bearing and non-weight-bearing measurement modalities","volume":"25","author":"Schoenmakers","year":"2017","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"10.1016\/j.knee.2019.11.017_bb0120","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.knee.2013.05.009","article-title":"Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment?","volume":"21","author":"Gbejuade","year":"2014","journal-title":"Knee"},{"issue":"4","key":"10.1016\/j.knee.2019.11.017_bb0125","doi-asserted-by":"crossref","first-page":"440","DOI":"10.3109\/17453674.2014.1003488","article-title":"Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment","volume":"86","author":"Holme","year":"2015","journal-title":"Acta Orthop"},{"issue":"5","key":"10.1016\/j.knee.2019.11.017_bb0130","doi-asserted-by":"crossref","first-page":"745","DOI":"10.2106\/00004623-198769050-00016","article-title":"Radiographic analysis of the axial alignment of the lower extremity","volume":"69","author":"Moreland","year":"1987","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"10.1016\/j.knee.2019.11.017_bb0135","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"issue":"2","key":"10.1016\/j.knee.2019.11.017_bb0140","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1002\/art.21836","article-title":"Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis?","volume":"55","author":"Hinman","year":"2006","journal-title":"Arthritis Rheum"},{"issue":"10","key":"10.1016\/j.knee.2019.11.017_bb0145","first-page":"2243","article-title":"Computed radiographic measurement of limb-length discrepancy. Full-length standing anteroposterior radiograph compared with scanogram","volume":"88","author":"Sabharwal","year":"2006","journal-title":"J Bone Joint Surg Am"},{"issue":"1080","key":"10.1016\/j.knee.2019.11.017_bb0150","doi-asserted-by":"crossref","first-page":"20170483","DOI":"10.1259\/bjr.20170483","article-title":"Radiation dose reduction in plain radiography of the full-length lower extremity and full spine","volume":"90","author":"Jeon","year":"2017","journal-title":"Br J Radiol"},{"issue":"4","key":"10.1016\/j.knee.2019.11.017_bb0155","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1136\/ard.16.4.494","article-title":"Radiological assessment of osteo-arthrosis","volume":"16","author":"Kellgren","year":"1957","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.knee.2019.11.017_bb0160","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/00003086-198708000-00037","article-title":"Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results","volume":"221","author":"Kennedy","year":"1987","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"10.1016\/j.knee.2019.11.017_bb0165","doi-asserted-by":"crossref","first-page":"2982","DOI":"10.1007\/s00167-014-3327-4","article-title":"Predicting knee rotation by the projection overlap of the proximal fibula and tibia in long-leg radiographs","volume":"22","author":"Maderbacher","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.knee.2019.11.017_bb0170","article-title":"Lower limb malrotation is regularly present in long-leg radiographs resulting in significant measurement errors","author":"Maderbacher","year":"2019","journal-title":"J Knee Surg"}],"container-title":["The Knee"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016019303072?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016019303072?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T21:50:24Z","timestamp":1760824224000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0968016019303072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["S0968016019303072"],"URL":"https:\/\/doi.org\/10.1016\/j.knee.2019.11.017","relation":{},"ISSN":["0968-0160"],"issn-type":[{"value":"0968-0160","type":"print"}],"subject":[],"published":{"date-parts":[[2020,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of weight-bearing full-length radiographs and computed-tomography-scan-based three-dimensional models in the assessment of knee joint coronal alignment","name":"articletitle","label":"Article Title"},{"value":"The Knee","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.knee.2019.11.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}