{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T00:40:05Z","timestamp":1760834405338,"version":"build-2065373602"},"reference-count":11,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100009026","name":"Smith and Nephew","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009026","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","thekneejournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Knee"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1016\/j.knee.2020.11.012","type":"journal-article","created":{"date-parts":[[2020,12,13]],"date-time":"2020-12-13T06:39:06Z","timestamp":1607841546000},"page":"97-103","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Instability, an unforeseen diagnosis of the Legion\u2122 hinge knee system"],"prefix":"10.1016","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7625-4259","authenticated-orcid":false,"given":"Simon N.","family":"van Laarhoven","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petra J.C.","family":"Heesterbeek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3720-8927","authenticated-orcid":false,"given":"Gijs G.","family":"van Hellemondt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.knee.2020.11.012_b0005","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1302\/2058-5241.4.180070","article-title":"The role of rotating hinge implants in revision total knee arthroplasty","volume":"4","author":"Pasquier","year":"2019","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.knee.2020.11.012_b0010","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1302\/2058-5241.4.180056","article-title":"Total knee arthroplasty using hinge joints: Indications and results","volume":"4","author":"Carlos","year":"2019","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.knee.2020.11.012_b0015","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jcot.2017.11.020","article-title":"Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature","volume":"9","author":"Kouk","year":"2018","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.knee.2020.11.012_b0020","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2013\/701693","article-title":"Evaluation of stability of rotating hinge knee prostheses: A biomechanical study","volume":"2013","author":"Friesenbichler","year":"2013","journal-title":"ISRN Orthop"},{"key":"10.1016\/j.knee.2020.11.012_b0025","doi-asserted-by":"crossref","first-page":"448","DOI":"10.2106\/00004623-200303000-00008","article-title":"Dislocation of rotating hinge total knee prostheses. A biomechanical analysis","volume":"85","author":"Ward","year":"2003","journal-title":"J Bone Jt Surg"},{"key":"10.1016\/j.knee.2020.11.012_b0030","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1016\/j.arth.2007.10.016","article-title":"Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?","volume":"23","author":"Joshi","year":"2008","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.knee.2020.11.012_b0035","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.2106\/00004623-200505000-00025","article-title":"Dislocation of rotating hinge knee prostheses: A report of four cases","volume":"87","author":"Ward","year":"2005","journal-title":"J Bone Jt Surg"},{"key":"10.1016\/j.knee.2020.11.012_b0040","unstructured":"smith-nephew.com [Internet]; n.d. www.smith-nephew.com\/global\/assets\/pdf\/products\/surgical\/legion_tks_primary_through_hinge_specifications_guide_02861v1.pdf [accessed April 23, 2020]."},{"key":"10.1016\/j.knee.2020.11.012_b0045","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/00003086-200511000-00018","article-title":"Flexion instability without dislocation after posterior stabilized total knees","volume":"440","author":"Schwab","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2020.11.012_b0050","doi-asserted-by":"crossref","first-page":"3614","DOI":"10.1007\/s00167-019-05474-7","article-title":"Mid-flexion laxity in the asymptomatic native knee is predominantly present on the lateral side","volume":"27","author":"te Molder","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.knee.2020.11.012_b0055","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.knee.2007.09.007","article-title":"In vivo knee laxity in flexion and extension: A radiographic study in 30 older healthy subjects","volume":"15","author":"Heesterbeek","year":"2008","journal-title":"Knee"}],"container-title":["The Knee"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S096801602030377X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S096801602030377X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T21:51:15Z","timestamp":1760824275000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S096801602030377X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":11,"alternative-id":["S096801602030377X"],"URL":"https:\/\/doi.org\/10.1016\/j.knee.2020.11.012","relation":{},"ISSN":["0968-0160"],"issn-type":[{"type":"print","value":"0968-0160"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Instability, an unforeseen diagnosis of the Legion\u2122 hinge knee system","name":"articletitle","label":"Article Title"},{"value":"The Knee","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.knee.2020.11.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}