{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T07:57:53Z","timestamp":1761897473642,"version":"build-2065373602"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","thekneejournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Knee"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1016\/j.knee.2021.01.005","type":"journal-article","created":{"date-parts":[[2021,1,29]],"date-time":"2021-01-29T05:04:06Z","timestamp":1611896646000},"page":"1-8","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Spherical center axial hinge knee prosthesis causes lower contact stress on tibial insert and bushing compared with biaxial hinge knee prosthesis"],"prefix":"10.1016","volume":"29","author":[{"given":"Jing-yu","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao-ran","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-mu","family":"Tian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9846-6735","authenticated-orcid":false,"given":"Yong-cheng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.knee.2021.01.005_b0005","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.arth.2007.05.055","article-title":"The role of the rotating hinge prosthesis in the salvage arthroplasty setting","volume":"23","author":"Deehan","year":"2008","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.knee.2021.01.005_b0010","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.otsr.2009.07.013","article-title":"Complications of following rotating hinge Endo-Modell (Link) knee arthroplasty","volume":"95","author":"Guenoun","year":"2009","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.knee.2021.01.005_b0015","doi-asserted-by":"crossref","first-page":"513","DOI":"10.2106\/00004623-198062040-00004","article-title":"Hinged total knee arthroplasty","volume":"62","author":"Hui","year":"1980","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.knee.2021.01.005_b0020","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jcot.2014.11.001","article-title":"Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty","volume":"6","author":"Rodr\u00edguez-Merch\u00e1n","year":"2015","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.knee.2021.01.005_b0025","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1302\/0301-620X.96B11.34747","article-title":"Classification of failure of limb salvage after reconstructive surgery for bone tumours: a modified system Including biological and expandable reconstructions","volume":"96-B","author":"Henderson","year":"2014","journal-title":"Bone Joint J"},{"key":"10.1016\/j.knee.2021.01.005_b0030","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1302\/2058-5241.4.180056","article-title":"Total knee arthroplasty using hinge joints: Indications and results","volume":"4","author":"Rodr\u00edguez-Merch\u00e1n","year":"2019","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.knee.2021.01.005_b0035","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1111\/os.12640","article-title":"Influence of congruency design on the contact stress of a novel hinged knee prosthesis using finite element analysis","volume":"12","author":"Zhang","year":"2020","journal-title":"Orthop Surg"},{"key":"10.1016\/j.knee.2021.01.005_b0040","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1302\/0301-620X.89B4.18631","article-title":"Endoprosthetic replacement of the distal femur for bone tumours: long-term results","volume":"89","author":"Myers","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.knee.2021.01.005_b0045","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.triboint.2016.10.050","article-title":"A patient-specific wear prediction framework for an artificial knee joint with coupled musculoskeletal multibodydynamics and finite element analysis","volume":"109","author":"Zhang","year":"2017","journal-title":"Tribol Int"},{"key":"10.1016\/j.knee.2021.01.005_b0050","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.otsr.2019.08.012","article-title":"Rotating-hinge knee prosthesis as a viable option in primary surgery: Literature review & meta-analysis","volume":"105","author":"Abdulkarim","year":"2019","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.knee.2021.01.005_b0055","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jcot.2017.11.020","article-title":"Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature","volume":"9","author":"Kouk","year":"2018","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.knee.2021.01.005_b0060","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s00402-019-03290-9","article-title":"Early complications and causes of revision after rotating-hinge TKA","volume":"140","author":"Rouquette","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.knee.2021.01.005_b0065","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2017.10.051","article-title":"Implant survival and complication profiles of endoprostheses for treating tumor around the knee in adults: A systematic review of the literature over the past 30 years","volume":"33","author":"Haijie","year":"2018","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.knee.2021.01.005_b0070","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1007\/s11999-015-4644-8","article-title":"What are the long-term results of MUTARS\u00ae modular endoprostheses for reconstruction of tumor resection of the distal femur and proximal tibia?","volume":"475","author":"Bus","year":"2017","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2021.01.005_b0075","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S0021-9290(03)00255-0","article-title":"Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations","volume":"37","author":"Villa","year":"2004","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2021.01.005_b0080","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/01.blo.0000079267.91782.58","article-title":"Explicit finite element simulation of eccentric loading in total knee replacement","volume":"414","author":"Taylor","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2021.01.005_b0085","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1302\/2058-5241.4.180070","article-title":"The role of rotating hinge implants in revision total knee arthroplasty","volume":"4","author":"Pasquier","year":"2019","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.knee.2021.01.005_b0090","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1302\/2046-3758.71.BJR-2017-0115.R2","article-title":"Patient-specific medial unicompartmental knee arthroplasty has a greater protective effect on articular cartilage in the lateral compartment: A finite element analysis","volume":"7","author":"Kang","year":"2018","journal-title":"Bone Joint Res"},{"key":"10.1016\/j.knee.2021.01.005_b0095","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/00003086-200111000-00029","article-title":"Polyethylene contact stresses, articular congruity, and knee alignment","volume":"392","author":"D\u2019Lima","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2021.01.005_b0100","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.knee.2020.04.022","article-title":"Spherical center and rotating platform hinged knee prosthesis: Finite-element model establishment, verification and contact analysis","volume":"27","author":"Zhang","year":"2020","journal-title":"Knee"},{"key":"10.1016\/j.knee.2021.01.005_b0105","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1177\/0954411917744586","article-title":"Customized surface-guided knee implant: Contact analysis and experimental test","volume":"232","author":"Khosravipour","year":"2018","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.knee.2021.01.005_b0110","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1007\/s00167-019-05593-1","article-title":"Acceptable mid- to long-term survival rates and functional outcomes following a single design rotating hinge total knee arthroplasty","volume":"28","author":"Theil","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.knee.2021.01.005_b0115","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.jbiomech.2013.11.042","article-title":"Dynamic contact stress patterns on the tibial plateaus during simulated gait: a novel application of normalized cross correlation","volume":"47","author":"Wang","year":"2014","journal-title":"J Biomech"},{"key":"10.1016\/j.knee.2021.01.005_b0120","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1177\/0954411913513251","article-title":"The effect of insert conformity and material on total knee replacement wear","volume":"228","author":"Abdelgaied","year":"2014","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.knee.2021.01.005_b0125","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1177\/0954411917746433","article-title":"Influence of conformity on the wear of total knee replacement: An experimental study","volume":"232","author":"Brockett","year":"2018","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.knee.2021.01.005_b0130","doi-asserted-by":"crossref","first-page":"324","DOI":"10.2106\/JBJS.16.00307","article-title":"Long-term results after total knee arthroplasty with contemporary rotating-hinge prostheses","volume":"99","author":"Cottino","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.knee.2021.01.005_b0135","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1097\/CORR.0000000000000528","article-title":"Cam FAI and smaller neck angles increase subchondral bone stresses during squatting: A finite element analysis","volume":"477","author":"Ng","year":"2019","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.knee.2021.01.005_b0140","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jbiomech.2018.07.008","article-title":"A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement","volume":"77","author":"Shu","year":"2018","journal-title":"J Biomech"}],"container-title":["The Knee"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016021000065?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0968016021000065?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T21:50:34Z","timestamp":1760824234000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0968016021000065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":28,"alternative-id":["S0968016021000065"],"URL":"https:\/\/doi.org\/10.1016\/j.knee.2021.01.005","relation":{},"ISSN":["0968-0160"],"issn-type":[{"type":"print","value":"0968-0160"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Spherical center axial hinge knee prosthesis causes lower contact stress on tibial insert and bushing compared with biaxial hinge knee prosthesis","name":"articletitle","label":"Article Title"},{"value":"The Knee","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.knee.2021.01.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}