{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T09:17:40Z","timestamp":1791883060732,"version":"4.3.4"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,4,1]],"date-time":"2016-04-01T00:00:00Z","timestamp":1459468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","lungcancerjournal.info","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Lung Cancer"],"published-print":{"date-parts":[[2016,4]]},"DOI":"10.1016\/j.lungcan.2016.01.017","type":"journal-article","created":{"date-parts":[[2016,1,28]],"date-time":"2016-01-28T03:48:48Z","timestamp":1453952928000},"page":"40-45","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":20,"special_numbering":"C","title":["Diagnostic accuracy of sequential co-registered PET+MR in comparison to PET\/CT in local thoracic staging of malignant pleural mesothelioma"],"prefix":"10.1016","volume":"94","author":[{"given":"Katharina","family":"Martini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3669-8677","authenticated-orcid":false,"given":"Andreas","family":"Meier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabelle","family":"Opitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter","family":"Weder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Veit-Haibach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rolf A.","family":"Stahel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Frauenfelder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.lungcan.2016.01.017_bib0005","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1148\/radiographics.12.6.1439021","article-title":"Imaging manifestations of pleural tumors","volume":"12","author":"Dynes","year":"1992","journal-title":"RadioGraphics"},{"key":"10.1016\/j.lungcan.2016.01.017_bib0010","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0046-8177(87)80354-4","article-title":"Current pathogenetic concepts of diffuse malignant mesothelioma","volume":"18","author":"Craighead","year":"1987","journal-title":"Hum. Pathol."},{"issue":"6","key":"10.1016\/j.lungcan.2016.01.017_bib0015","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1148\/rg.346130089","article-title":"Multimodality imaging for characterization, classification, and staging of malignant pleural mesothelioma","volume":"34","author":"Nickel","year":"2014","journal-title":"RadioGraphics"},{"issue":"1","key":"10.1016\/j.lungcan.2016.01.017_bib0020","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1148\/rg.241035058","article-title":"Malignant pleural mesothelioma: evaluation with CT, MR imaging, and PET","volume":"24","author":"Wang","year":"2004","journal-title":"RadioGraphics"},{"issue":"April (12)","key":"10.1016\/j.lungcan.2016.01.017_bib0025","first-page":"9","article-title":"Malignant Pleural Mesothelioma","volume":"27","author":"Tsao","year":"2009","journal-title":"J. Clin. Oncol."},{"issue":"1","key":"10.1016\/j.lungcan.2016.01.017_bib0030","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1053\/sonc.2002.30228","article-title":"The role of imaging in malignant pleural mesothelioma","volume":"29","author":"Marom","year":"2002","journal-title":"Semin. Oncol."},{"issue":"12","key":"10.1016\/j.lungcan.2016.01.017_bib0035","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1097\/JTO.0b013e3181c0a7ff","article-title":"Clinical value of fluorodeoxyglucose-positron emission tomography\/computed tomography in differentiation of malignant mesothelioma from asbestos-related benign pleural disease: an observational pilot study","volume":"4","author":"Yildirim","year":"2009","journal-title":"J. Thorac. Oncol."},{"issue":"24","key":"10.1016\/j.lungcan.2016.01.017_bib0040","doi-asserted-by":"crossref","first-page":"3199","DOI":"10.1001\/jama.290.24.3199","article-title":"Whole-body dual-modality pet\/ct and whole-body mri for tumor staging in oncology","volume":"290","author":"Antoch","year":"2003","journal-title":"JAMA"},{"issue":"6","key":"10.1016\/j.lungcan.2016.01.017_bib0045","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1007\/s00259-008-0734-0","article-title":"MR-based attenuation correction for torso-PET\/MR imaging: pitfalls in mapping MR to CT data","volume":"35","author":"Beyer","year":"2008","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"4","key":"10.1016\/j.lungcan.2016.01.017_bib0050","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s13244-013-0247-7","article-title":"PET\/CT versus body coil PET\/MRI: how low can you go?","volume":"4","author":"Appenzeller","year":"2013","journal-title":"Insights Imaging"},{"issue":"4","key":"10.1016\/j.lungcan.2016.01.017_bib0055","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.2214\/ajr.172.4.10587144","article-title":"Staging of malignant pleural mesothelioma: comparison of CT and MR imaging","volume":"172","author":"Heelan","year":"1999","journal-title":"Am. J. Roentgenol."},{"issue":"3","key":"10.1016\/j.lungcan.2016.01.017_bib0060","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1148\/radiol.14140090","article-title":"Whole-body nonenhanced PET\/MR versus PET\/CT in the staging and restaging of cancers: preliminary observations","volume":"273","author":"H\u00fcllner","year":"2014","journal-title":"Radiology"},{"issue":"2","key":"10.1016\/j.lungcan.2016.01.017_bib0065","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1148\/radiol.12111942","article-title":"Pulmonary lesion assessment: comparison of whole-body hybrid MR\/PET and PET\/CT imaging\u2014pilot study","volume":"264","author":"Schwenzer","year":"2012","journal-title":"Radiology"},{"issue":"12","key":"10.1016\/j.lungcan.2016.01.017_bib0070","doi-asserted-by":"crossref","first-page":"2212","DOI":"10.1007\/s00259-014-2867-7","article-title":"Use of diffusion-weighted imaging (DWI) in PET\/MRI for head and neck cancer evaluation","volume":"41","author":"Queiroz","year":"2014","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"6","key":"10.1016\/j.lungcan.2016.01.017_bib0075","first-page":"1066","article-title":"PET\/MRI and PET\/CT in follow-up of head and neck cancer patients","volume":"41","author":"Queiroz","year":"2014","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"2","key":"10.1016\/j.lungcan.2016.01.017_bib0080","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/MNM.0000000000000229","article-title":"Image registration accuracy of an in-house developed patient transport system for PET\/CT+MR and SPECT+CT imaging","volume":"36","author":"Samarin","year":"2015","journal-title":"Nuclear Med. Commun."},{"issue":"8","key":"10.1016\/j.lungcan.2016.01.017_bib0085","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1097\/JTO.0b013e3182208e3f","volume":"6","author":"Rice","year":"2011","journal-title":"Journal of Thoracic Oncology"},{"key":"10.1016\/j.lungcan.2016.01.017_bib0090","first-page":"6","article-title":"A proposed new international TNM staging system for malignant pleura mesothelioma: from the International Mesothelioma Interest Group","volume":"108","author":"Rusch","year":"1995","journal-title":"Chest"},{"key":"10.1016\/j.lungcan.2016.01.017_bib0095","first-page":"159","article-title":"The measurement of observer agreement for categorical data","volume":"16","author":"Landis","year":"1997","journal-title":"Biometrics"},{"issue":"1","key":"10.1016\/j.lungcan.2016.01.017_bib0100","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s00259-008-0940-9","article-title":"A look ahead: PET\/MR versus PET\/CT","volume":"36","author":"von Schulthess","year":"2009","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"3","key":"10.1016\/j.lungcan.2016.01.017_bib0105","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1148\/radiol.13131306","article-title":"Clinical impact of PET\/MR imaging in patients with cancer undergoing same-day PET\/CT: initial experience in 134 patients\u2014a hypothesis-generating exploratory study","volume":"269","author":"Catalano","year":"2013","journal-title":"Radiology"},{"issue":"11","key":"10.1016\/j.lungcan.2016.01.017_bib0110","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1097\/JTO.0b013e31826915f1","article-title":"Initial analysis of the international association for the study of lung cancer mesothelioma database","volume":"7","author":"Rusch","year":"2012","journal-title":"J. Thorac. Oncol."},{"key":"10.1016\/j.lungcan.2016.01.017_bib0115","article-title":"Use of computed tomography and positron emission tomography\/computed tomography for staging of local extent in patients with malignant pleural mesothelioma","author":"Frauenfelder","year":"2016","journal-title":"J. Comput. Assist. Tomogr."},{"issue":"10","key":"10.1016\/j.lungcan.2016.01.017_bib0120","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1097\/RLI.0b013e3181817b3d","article-title":"Computed tomography, positron emission tomography, positron emission Tomography\/Computed tomography, and magnetic resonance imaging for staging of limited pleural mesothelioma: initial results","volume":"43","author":"Plathow","year":"2008","journal-title":"Invest. Radiol."},{"issue":"9","key":"10.1016\/j.lungcan.2016.01.017_bib0125","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1007\/s00259-011-1842-9","article-title":"Value of a dixon-based MR\/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions","volume":"38","author":"Eiber","year":"2011","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"1","key":"10.1016\/j.lungcan.2016.01.017_bib0130","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0022-5223(03)00207-1","article-title":"Positron emission tomography defines metastatic disease but not locoregional disease in patients with malignant pleural mesothelioma","volume":"126","author":"Flores","year":"2003","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"3","key":"10.1016\/j.lungcan.2016.01.017_bib0135","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1148\/radiol.14140090","article-title":"Whole-body nonenhanced PET\/MR versus PET\/CT in the staging and restaging of cancers: preliminary observations","volume":"273","author":"Huellner","year":"2014","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.lungcan.2016.01.017_bib0140","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1378\/chest.108.4.1122","article-title":"A proposed new international tnm staging system for malignant pleural mesothelioma","volume":"108","author":"Rusch","year":"1995","journal-title":"Chest"}],"container-title":["Lung Cancer"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169500216300150?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169500216300150?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,9,3]],"date-time":"2019-09-03T22:31:04Z","timestamp":1567549864000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0169500216300150"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4]]},"references-count":28,"alternative-id":["S0169500216300150"],"URL":"https:\/\/doi.org\/10.1016\/j.lungcan.2016.01.017","relation":{},"ISSN":["0169-5002"],"issn-type":[{"value":"0169-5002","type":"print"}],"subject":[],"published":{"date-parts":[[2016,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Diagnostic accuracy of sequential co-registered PET+MR in comparison to PET\/CT in local thoracic staging of malignant pleural mesothelioma","name":"articletitle","label":"Article Title"},{"value":"Lung Cancer","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.lungcan.2016.01.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}