{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T17:08:28Z","timestamp":1781629708984,"version":"3.54.5"},"reference-count":34,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","meddos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Medical Dosimetry"],"published-print":{"date-parts":[[2020]]},"DOI":"10.1016\/j.meddos.2019.09.001","type":"journal-article","created":{"date-parts":[[2019,11,9]],"date-time":"2019-11-09T01:06:32Z","timestamp":1573261592000},"page":"153-158","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"title":["Surface dose and acute skin reactions in external beam breast radiotherapy"],"prefix":"10.1016","volume":"45","author":[{"given":"Patrick N.","family":"McDermott","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.meddos.2019.09.001_bib0001","doi-asserted-by":"crossref","first-page":"p260","DOI":"10.1002\/pon.1734","article-title":"A qualitative analysis of acute skin toxicity among breast cancer radiotherapy patients","volume":"20","author":"Schnur","year":"2011","journal-title":"Psychooncology"},{"key":"10.1016\/j.meddos.2019.09.001_bib0002","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1200\/JCO.2007.15.2488","article-title":"A multicenter randomized trial of breast intensity modulated radiation therapy to reduce acute radiation dermatitis","volume":"26","author":"Pignol","year":"2008","journal-title":"J Clin Oncol"},{"issue":"1","key":"10.1016\/j.meddos.2019.09.001_bib0003","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.meddos.2018.01.004","article-title":"Modifiable risk factors for acute skin toxicity in adjuvant breast radiotherapy: Dosimetric analysis and review of the literature","volume":"44","author":"Keenan","year":"2019","journal-title":"Med Dosim"},{"key":"10.1016\/j.meddos.2019.09.001_bib0004","doi-asserted-by":"crossref","first-page":"313","DOI":"10.2147\/BCTT.S109763","article-title":"Acute radiation dermatitis in breast cancer patients: Challenges and solutions","volume":"9","author":"Kole","year":"2017","journal-title":"Breast Cancer \u2013 Targets Ther"},{"key":"10.1016\/j.meddos.2019.09.001_bib0005","unstructured":"Savarse, D.M., Reed, D.E. and Tirnauer, J.S., https:\/\/www.uptodate.com\/contents\/common-terminology-criteria-for-adverse-events, accessed Aug. 2018."},{"key":"10.1016\/j.meddos.2019.09.001_bib0006","doi-asserted-by":"crossref","first-page":"2665","DOI":"10.1016\/j.ejca.2011.06.039","article-title":"Frequency and severity of skin reactions in patients with breast cancer undergoing adjuvant radiotherapy, the usefulness of two assessment instruments \u2013 a pilot study","volume":"47","author":"Sharp","year":"2011","journal-title":"Eur J Cancer"},{"issue":"5","key":"10.1016\/j.meddos.2019.09.001_bib0007","doi-asserted-by":"crossref","first-page":"e825","DOI":"10.1016\/j.clbc.2018.06.015","article-title":"Radiation-induced skin toxicity in breast cancer patients: A systematic review of randomized trials","volume":"18","author":"Yee","year":"2018","journal-title":"Clin Breast Cancer"},{"key":"10.1016\/j.meddos.2019.09.001_bib0008","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.breast.2016.07.013","article-title":"Factors influencing acute and late toxicity in the era of adjuvant hypofractionated breast radiotherapy","volume":"29","author":"DeSantis","year":"2016","journal-title":"Breast"},{"issue":"5","key":"10.1016\/j.meddos.2019.09.001_bib0009","doi-asserted-by":"crossref","first-page":"e789","DOI":"10.1016\/j.clbc.2018.03.008","article-title":"Prospective study of breast radiation dermatitis","volume":"18","author":"Drost","year":"2018","journal-title":"Clin Breast Cancer"},{"key":"10.1016\/j.meddos.2019.09.001_bib0010","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.adro.2017.10.007","article-title":"Predictors of radiation-induced acute skin toxicity in breast cancer at a single institution: Role of fractionation and treatment volume","volume":"3","author":"Perekh","year":"2018","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.meddos.2019.09.001_bib0011","first-page":"47","article-title":"The acute effects of different energy beta-emitters on pig and mouse skin","volume":"19","author":"Hopewell","year":"1986","journal-title":"Br J Radiol Suppl"},{"key":"10.1016\/j.meddos.2019.09.001_bib0012","unstructured":"ICRU Report 39, Determination of dose equivalents from external radiation sources, international commission on radiation units and measurements. 1985."},{"key":"10.1016\/j.meddos.2019.09.001_bib0013","article-title":"The biological basis for dose limitation in the skin","volume":"22","year":"1992","journal-title":"Ann. ICRP"},{"key":"10.1016\/j.meddos.2019.09.001_bib0014","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1118\/1.598373","article-title":"American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planning","volume":"25","author":"Fraass","year":"2010","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0015","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s13555-016-0120-y","article-title":"Acute and Chronic Cutaneous Reactions to Ionizing Radiation Therapy","volume":"6","author":"Bray","year":"2016","journal-title":"Dermatol Ther"},{"key":"10.1016\/j.meddos.2019.09.001_bib0016","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1038\/jid.2011.411","article-title":"Ionizing radiation: The good, the bad and the ugly","volume":"132","author":"Ryan","year":"2012","journal-title":"J Invest Dermatol"},{"key":"10.1016\/j.meddos.2019.09.001_bib0017","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/0360-3016(94)00423-I","article-title":"Pathophysiology of irradiated skin and breast","volume":"31","author":"Archambeau","year":"1995","journal-title":"Int. J. Radiation Oncology Biol. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0018","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1120\/jacmp.v13i3.3734","article-title":"Skin dose during radiotherapy: a summary and general estimation technique","volume":"13","author":"Kry","year":"2012","journal-title":"JACMP"},{"key":"10.1016\/j.meddos.2019.09.001_bib0019","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1120\/jacmp.v4i1.2537","article-title":"Surface and buildup dose characteritics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator","volume":"4","author":"Klein","year":"2003","journal-title":"JACMP"},{"key":"10.1016\/j.meddos.2019.09.001_bib0020","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1118\/1.595908","article-title":"Buildup\/surface dose and exit dose measurements for a 6 MV linear accelerator","volume":"13","author":"Purdy","year":"1986","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0021","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1118\/1.596055","article-title":"Dose buildup for obliquely incident photon beams","volume":"14","author":"Gerbi","year":"1987","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0022","doi-asserted-by":"crossref","DOI":"10.1118\/1.4876299","article-title":"et al., Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176","volume":"41","author":"Olch","year":"2014","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0023","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.ejmp.2016.10.022","article-title":"et al., In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy","volume":"32","author":"Jong","year":"2016","journal-title":"Physica Med"},{"key":"10.1016\/j.meddos.2019.09.001_bib0024","series-title":"Surface Dosimetry in Breast Radiotherapy, Masters thesis, Centre for Medical Radiation Physics, Engineering Physics","author":"Kelly","year":"2010"},{"key":"10.1016\/j.meddos.2019.09.001_bib0025","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1088\/0031-9155\/41\/6\/011","article-title":"Radiochromic film as a radiotherapy surface-dose detector","volume":"41","author":"Butson","year":"1996","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.meddos.2019.09.001_bib0026","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1120\/jacmp.v9i1.2792","article-title":"Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system","volume":"9","author":"Court","year":"2008","journal-title":"JACMP"},{"key":"10.1016\/j.meddos.2019.09.001_bib0027","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.radonc.2011.06.021","article-title":"Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries","volume":"102","author":"Chakarova","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.meddos.2019.09.001_bib0028","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.radonc.2009.05.010","article-title":"AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE","volume":"93","author":"Panettieri","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.meddos.2019.09.001_bib0029","doi-asserted-by":"crossref","first-page":"4186","DOI":"10.1118\/1.2969070","article-title":"Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM","volume":"35","author":"Das","year":"2008","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0030","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1118\/1.596522","article-title":"Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers","volume":"17","author":"Gerbi","year":"1990","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2019.09.001_bib0031","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.meddos.2016.02.002","article-title":"Evaluating the consistency of the most severe acute skin reaction and the highest skin dose measured by thermoluminescent dosimeter during radiotherapy for breast cancer","volume":"41","author":"Sun","year":"2016","journal-title":"Med Dosim"},{"key":"10.1016\/j.meddos.2019.09.001_bib0032","doi-asserted-by":"crossref","first-page":"466","DOI":"10.3109\/0284186X.2015.1110253","article-title":"Dose-surface analysis for prediction of severe acute radio-induced skin toxicity in breast cancer patients","volume":"55","author":"Pastore","year":"2016","journal-title":"Acta Oncol (Madr)"},{"key":"10.1016\/j.meddos.2019.09.001_bib0033","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1088\/0031-9155\/43\/5\/006","article-title":"Investigation and modeling of the surface dose from linear accelerator produced 6 and 10 MV photon beams","volume":"43","author":"Lamb","year":"1998","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.meddos.2019.09.001_bib0034","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/0360-3016(93)90256-U","article-title":"Entrance and exit dose regions for a Clinac-2100C","volume":"27","author":"Klein","year":"1993","journal-title":"Int. J. Radiation Oncology Biol. Phys."}],"container-title":["Medical Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394719301025?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394719301025?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T09:31:48Z","timestamp":1760693508000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0958394719301025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"alternative-id":["S0958394719301025"],"URL":"https:\/\/doi.org\/10.1016\/j.meddos.2019.09.001","relation":{},"ISSN":["0958-3947"],"issn-type":[{"value":"0958-3947","type":"print"}],"subject":[],"published":{"date-parts":[[2020]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Surface dose and acute skin reactions in external beam breast radiotherapy","name":"articletitle","label":"Article Title"},{"value":"Medical Dosimetry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.meddos.2019.09.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}