{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T00:16:32Z","timestamp":1760746592790,"version":"build-2065373602"},"reference-count":22,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100006593","name":"Board of Research in Nuclear Sciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100006593","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","meddos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Medical Dosimetry"],"published-print":{"date-parts":[[2021]]},"DOI":"10.1016\/j.meddos.2020.09.002","type":"journal-article","created":{"date-parts":[[2020,9,25]],"date-time":"2020-09-25T11:32:29Z","timestamp":1601033549000},"page":"80-85","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy of MLC based cobalt\u201060 plans: A DVH comparison and analysis with 6 MV plans"],"prefix":"10.1016","volume":"46","author":[{"given":"Akula Roopa","family":"Rani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Komanduri","family":"Ayyangar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.R.","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayyalasomayajula Anil","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pal Reddy Yadagiri","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.meddos.2020.09.002_bib0001","first-page":"781","article-title":"Debate - obsolence of telecobalt machine: is there is a scope for resurrection?","volume":"10","author":"Huilgol","year":"2014","journal-title":"J Can Res Ther"},{"key":"10.1016\/j.meddos.2020.09.002_bib0002","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.ijrobp.2013.12.022","article-title":"Cobalt, Linac, or other: what is the best solution for radiation therapy in developing countries?","volume":"89","author":"Page","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0003","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1016\/j.ijrobp.2014.12.060","article-title":"Revisiting cobalt 60 teletherapy. In regard to page et al","volume":"91","author":"Ravichandran","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0004","doi-asserted-by":"crossref","first-page":"63","DOI":"10.4103\/0971-6203.51931","article-title":"Has the time come for doing away with cobalt-60 teletherapy for cancer treatments","volume":"34","author":"Ravichandran","year":"2009","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0005","series-title":"Appendix I. Comprehensive Audits of Radiotherapy Practices: A Tool for Quality Improvement (QUATRO)","first-page":"67","article-title":"Radiation oncology in limited resource settings","year":"2007"},{"issue":"1","key":"10.1016\/j.meddos.2020.09.002_bib0006","first-page":"19","article-title":"Design and development of an add-on automated multi leaf collimator for telecobalt therapy machine and study of its characteristics","volume":"6","author":"Roopa Rani","year":"2018","journal-title":"Int J Cancer Ther Oncol"},{"issue":"297","key":"10.1016\/j.meddos.2020.09.002_bib0007","first-page":"27","article-title":"Bhabhatron: an indigenous telecobalt machine for cancer treatment","author":"Jayarajan","year":"2008","journal-title":"BARC News Lett"},{"key":"10.1016\/j.meddos.2020.09.002_bib0008","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1259\/bjr\/77023750","article-title":"A comparison between cobalt and linear accelerator-based treatment plans for conformal and intensity-modulated radiotherapy","volume":"81","author":"Adams","year":"2008","journal-title":"Br J Radiol"},{"issue":"2","key":"10.1016\/j.meddos.2020.09.002_bib0009","doi-asserted-by":"crossref","first-page":"73","DOI":"10.4103\/0971-6203.62197","article-title":"Dosimetry of interface region near closed aircavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations","volume":"35","author":"Chandra","year":"2010","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0010","doi-asserted-by":"crossref","first-page":"125","DOI":"10.4103\/0971-6203.116367","article-title":"Forward planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer","volume":"38","author":"Cilla","year":"2013","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0011","doi-asserted-by":"crossref","first-page":"3175","DOI":"10.1088\/0031-9155\/53\/12\/007","article-title":"Comparative analysis of 60Co intensity-modulated radiation therapy","volume":"53","author":"Fox","year":"2008","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.meddos.2020.09.002_bib0012","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1120\/jacmp.v14i3.4214","article-title":"Fast MonteCarlo simulation for total body irradiation using a 60Co teletherapy unit","volume":"14","author":"Liu","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0013","doi-asserted-by":"crossref","first-page":"133","DOI":"10.4103\/0971-6203.54846","article-title":"The role of Cobalt 60 in modern radiation therapy: dose delivery and image guidance","volume":"34","author":"Schreiner","year":"2009","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0014","doi-asserted-by":"crossref","first-page":"135","DOI":"10.4103\/jmp.JMP_20_19","article-title":"External beam radiotherapy with telecobalt machine: Tissue deficiency compensation in head-and-neck region and effect on skin reactions","volume":"44","author":"Ravichandran","year":"2019","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0015","series-title":"Proceedings of 32ndAnnual Conference of Association of Medical Physicists of India (AMPICON)","first-page":"15","article-title":"Development of an automated MLC for telecobalt therapy machine with a potential for conformal therapy","author":"Ayyangar","year":"2011"},{"issue":"2","key":"10.1016\/j.meddos.2020.09.002_bib0016","doi-asserted-by":"crossref","first-page":"71","DOI":"10.4103\/0971-6203.131279","article-title":"Monte Carlo study of MLC fields for cobalt therapy machine","volume":"39","author":"Ayyangar","year":"2014","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0017","doi-asserted-by":"crossref","first-page":"431","DOI":"10.14319\/ijcto.43.1","article-title":"DVH Analysis of Cobalt-60 treatment plans incorporating a recently developed MLC","volume":"4","author":"Sri Krishna","year":"2016","journal-title":"Int J Cancer Ther Oncol"},{"key":"10.1016\/j.meddos.2020.09.002_bib0018","series-title":"Proceedings of 37th Annual Conference of Association of Medical Physicists of India (AMPICON)","article-title":"Comparison of MLC based Cobalt-60 plans with 6 MV: A DVH analysis","author":"Roopa Rani","year":"2016"},{"key":"10.1016\/j.meddos.2020.09.002_bib0019","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1120\/jacmp.v17i3.6020","article-title":"In\u2010house quality check of external beam plans using 3D treatment planning systems - a DVH comparison","volume":"17","author":"Kumar","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0020","doi-asserted-by":"crossref","first-page":"71","DOI":"10.4103\/0971-6203.131279","article-title":"Monte Carlo study of MLC fields for cobalt therapy machine","volume":"39","author":"Ayyangar","year":"2014","journal-title":"J Med Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0021","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.ijrobp.2005.09.028","article-title":"Conformity index: a review","volume":"64","author":"Feuvret","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.meddos.2020.09.002_bib0022","doi-asserted-by":"crossref","first-page":"207","DOI":"10.4103\/0971-6203.103606","article-title":"Homogeneity index: an objective tool for assessment of conformal radiation treatments","volume":"37","author":"Kataria","year":"2012","journal-title":"J Med Phys"}],"container-title":["Medical Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394720301291?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394720301291?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T09:31:12Z","timestamp":1760693472000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0958394720301291"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"alternative-id":["S0958394720301291"],"URL":"https:\/\/doi.org\/10.1016\/j.meddos.2020.09.002","relation":{},"ISSN":["0958-3947"],"issn-type":[{"type":"print","value":"0958-3947"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Efficacy of MLC based cobalt\u201060 plans: A DVH comparison and analysis with 6 MV plans","name":"articletitle","label":"Article Title"},{"value":"Medical Dosimetry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.meddos.2020.09.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}