{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T17:32:04Z","timestamp":1789061524951,"version":"build-2803163510"},"reference-count":18,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","meddos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Medical Dosimetry"],"published-print":{"date-parts":[[2025]]},"DOI":"10.1016\/j.meddos.2025.04.005","type":"journal-article","created":{"date-parts":[[2025,5,28]],"date-time":"2025-05-28T07:16:43Z","timestamp":1748416603000},"page":"337-343","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Dosimetric evaluation of target and peri-cavity by replacing CT values for cavities within the target in volumetric modulated arc therapy"],"prefix":"10.1016","volume":"50","author":[{"given":"Hiroto","family":"Adachi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-9941-6341","authenticated-orcid":false,"given":"Keisuke","family":"Usui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiro","family":"Arita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenta","family":"Suga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sae","family":"Kamiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-8570-381X","authenticated-orcid":false,"given":"Shinsuke","family":"Kyogoku","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Daida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.meddos.2025.04.005_bib0001","volume":"36","year":"2020"},{"key":"10.1016\/j.meddos.2025.04.005_bib0002","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1002\/acm2.12652","article-title":"Evaluation of auto-planning in IMRT and VMAT for head and neck cancer","volume":"20","author":"Ouyang","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"10.1016\/j.meddos.2025.04.005_bib0003","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.ijrobp.2010.11.030","article-title":"Mutic S. Experience-based quality control of clinical intensity-modulated radiotherapy planning","volume":"81","author":"Moore","year":"2011","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"10.1016\/j.meddos.2025.04.005_bib0004","doi-asserted-by":"crossref","first-page":"e99","DOI":"10.1016\/j.prro.2012.06.009","article-title":"How important is dosimetrist experience for intensity modulated radiation therapy? A comparative analysis of a head and neck case","volume":"3","author":"Batumalai","year":"2013","journal-title":"Pract. Radiat. Oncol."},{"key":"10.1016\/j.meddos.2025.04.005_bib0005","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.prro.2011.11.012","article-title":"Variation in external beam treatment plan quality: An inter-institutional study of planners and planning systems","volume":"2","author":"Nelms","year":"2012","journal-title":"Pract. Radiat. Oncol."},{"key":"10.1016\/j.meddos.2025.04.005_bib0006","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1118\/1.598966","article-title":"A systematic evaluation of air cavity dose perturbation in megavoltage x-ray beams","volume":"27","author":"Li","year":"2000","journal-title":"Med. Phys."},{"key":"10.1016\/j.meddos.2025.04.005_bib0007","doi-asserted-by":"crossref","first-page":"5937","DOI":"10.1088\/0031-9155\/51\/22\/015","article-title":"Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations","volume":"51","author":"Behrens","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.meddos.2025.04.005_bib0008","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.meddos.2012.07.002","article-title":"Comparative dosimetry of volumetric modulated arc therapy and limited-angle static intensity-modulated radiation therapy for early-stage larynx cancer","volume":"38","author":"Riegel","year":"2013","journal-title":"Med. Dosim."},{"key":"10.1016\/j.meddos.2025.04.005_bib0009","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1111\/1754-9485.12227","article-title":"Dosimetric and radiobiologic comparison of 3D conformal, IMRT, VMAT and proton therapy for the treatment of early-stage glottic cancer","volume":"59","author":"Matthiesen","year":"2015","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"10.1016\/j.meddos.2025.04.005_bib0010","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.meddos.2021.07.005","article-title":"Dosimetric effect of intensity-modulated radiation therapy for postoperative non-small cell lung cancer with and without air cavity in the planning target volume","volume":"47","author":"Gan","year":"2022","journal-title":"Med. Dosim."},{"key":"10.1016\/j.meddos.2025.04.005_bib0011","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.meddos.2019.02.007","article-title":"Dosimetric comparison of intensity-modulated radiation therapy for early-stage glottic cancers with and without the air cavity in the planning target volume","volume":"44","author":"Asher","year":"2019","journal-title":"Med. Dosim."},{"key":"10.1016\/j.meddos.2025.04.005_bib0012","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1093\/jrr\/rrad057","article-title":"Planning strategies for robust carbon-ion scanning radiotherapy for stage I esophageal cancer: A retrospective study","volume":"64","author":"Suga","year":"2023","journal-title":"J. Radiat. Res."},{"key":"10.1016\/j.meddos.2025.04.005_bib0013","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1007\/s10278-013-9622-7","article-title":"The Cancer Imaging Archive (TCIA): Maintaining and operating a public information repository","volume":"26","author":"Clark","year":"2013","journal-title":"J. Digit Imaging"},{"key":"10.1016\/j.meddos.2025.04.005_bib0014","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1002\/acm2.12739","article-title":"A new homogeneity index definition for evaluation of radiotherapy plans","volume":"20","author":"Yan","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"10.1016\/j.meddos.2025.04.005_bib0015","series-title":"Report 83: Prescribing, Recording, and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT)","year":"2010"},{"key":"10.1016\/j.meddos.2025.04.005_bib0016","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.semradonc.2015.11.002","article-title":"Dose and volume of the irradiated main bronchi and related side effects in the treatment of Central lung tumors with stereotactic radiotherapy","volume":"26","author":"Duijm","year":"2016","journal-title":"Semin. Radiat. Oncol."},{"key":"10.1016\/j.meddos.2025.04.005_bib0017","doi-asserted-by":"crossref","first-page":"S355","DOI":"10.1088\/1361-6498\/ac28ef","article-title":"Medical consequences of radiation exposure of the bronchi\u2014What can we learn from high-dose precision radiation therapy?","volume":"41","author":"Lindberg","year":"2021","journal-title":"J. Radiol. Prot."},{"key":"10.1016\/j.meddos.2025.04.005_bib0018","doi-asserted-by":"crossref","first-page":"2390","DOI":"10.1111\/1759-7714.14561","article-title":"Radiation-induced pseudomembranous tracheobronchitis: A report of two cases","volume":"13","author":"Choi","year":"2022","journal-title":"Thorac. Cancer"}],"container-title":["Medical Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394725000299?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394725000299?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T13:38:42Z","timestamp":1762004322000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0958394725000299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"alternative-id":["S0958394725000299"],"URL":"https:\/\/doi.org\/10.1016\/j.meddos.2025.04.005","relation":{},"ISSN":["0958-3947"],"issn-type":[{"value":"0958-3947","type":"print"}],"subject":[],"published":{"date-parts":[[2025]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dosimetric evaluation of target and peri-cavity by replacing CT values for cavities within the target in volumetric modulated arc therapy","name":"articletitle","label":"Article Title"},{"value":"Medical Dosimetry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.meddos.2025.04.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}