{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:10:13Z","timestamp":1786122613141,"version":"build-2736575974"},"reference-count":40,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T00:00:00Z","timestamp":1772409600000},"content-version":"vor","delay-in-days":60,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","meddos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Medical Dosimetry"],"published-print":{"date-parts":[[2026]]},"DOI":"10.1016\/j.meddos.2026.02.002","type":"journal-article","created":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T11:15:38Z","timestamp":1775646938000},"page":"301-309","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dose calculation algorithm evaluation for cardiac radioablation of ventricular tachycardia"],"prefix":"10.1016","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-4945-043X","authenticated-orcid":false,"given":"Michael T.","family":"Prusator","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas R.","family":"Mazur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8937-6175","authenticated-orcid":false,"given":"Wesley W.","family":"Tucker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5183-2841","authenticated-orcid":false,"given":"Francisco J.","family":"Reynoso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew B.","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela P.","family":"Samson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clifford G.","family":"Robinson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Cuculich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sreekrishna Murty","family":"Goddu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3775-9354","authenticated-orcid":false,"given":"Kaitlin","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4109-8177","authenticated-orcid":false,"given":"Geoffrey D.","family":"Hugo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Cooper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rugheed","family":"Ghadban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nels C.","family":"Knutson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"14","key":"10.1016\/j.meddos.2026.02.002_bib0001","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.jacc.2017.10.054","article-title":"2017 AHA\/ACC\/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death","volume":"72","author":"Al-Khatib","year":"2018","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"10.1016\/j.meddos.2026.02.002_bib0002","doi-asserted-by":"crossref","first-page":"238","DOI":"10.15420\/aer.2018.37.2","article-title":"Team management of the ventricular tachycardia patient","volume":"7","author":"Tang","year":"2018","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"10.1016\/j.meddos.2026.02.002_bib0003","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.amjcard.2022.03.038","article-title":"Meta-analysis of catheter ablation outcomes in patients with cardiac sarcoidosis refractory ventricular tachycardia","volume":"174","author":"Adhaduk","year":"2022","journal-title":"Am J Cardiol"},{"issue":"3","key":"10.1016\/j.meddos.2026.02.002_bib0004","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1161\/CIRCULATIONAHA.118.038261","article-title":"Phase I\/II trial of electrophysiology-guided noninvasive cardiac radioablation for ventricular tachycardia","volume":"139","author":"Robinson","year":"2019","journal-title":"Circulation"},{"issue":"24","key":"10.1016\/j.meddos.2026.02.002_bib0005","doi-asserted-by":"crossref","first-page":"2325","DOI":"10.1056\/NEJMoa1613773","article-title":"Noninvasiv cardiac radiation for ablation of ventricular tachycardia","volume":"337","author":"Cuculich","year":"2017","journal-title":"N Engl J Med"},{"issue":"6","key":"10.1016\/j.meddos.2026.02.002_bib0006","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1097\/COC.0b013e3180ca7cb1","article-title":"Stereotactic body radiation therapy: a comprehensive review","volume":"30","author":"Chang","year":"2007","journal-title":"Am J Clin Oncol"},{"issue":"5","key":"10.1016\/j.meddos.2026.02.002_bib0007","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1016\/j.ijrobp.2019.04.005","article-title":"Radiation therapy workflow and dosimetric analysis from a phase \u00bd trial of noninvasive cardiac radioablation for ventricular tachycardia","volume":"104","author":"Knutson","year":"2019","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"7","key":"10.1016\/j.meddos.2026.02.002_bib0008","first-page":"694","article-title":"Stereotactic arrhythmia radioablation (STAR) of ventricular tachycardia: a treatment planning study","volume":"8","author":"Wang","year":"2016","journal-title":"Cureus"},{"issue":"8","key":"10.1016\/j.meddos.2026.02.002_bib0009","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1016\/j.hrthm.2020.02.036","article-title":"Stereotactic arrhythmia radioablation for refractory scar-related ventricular tachycardia","volume":"17","author":"Gianni","year":"2020","journal-title":"Heart Rhythm"},{"issue":"14","key":"10.1016\/j.meddos.2026.02.002_bib0010","doi-asserted-by":"crossref","first-page":"3821","DOI":"10.1088\/0031-9155\/53\/14\/008","article-title":"A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media","volume":"53","author":"Tillikainen","year":"2008","journal-title":"Phys Med Biol"},{"issue":"6","key":"10.1016\/j.meddos.2026.02.002_bib0011","doi-asserted-by":"crossref","first-page":"1879","DOI":"10.1088\/0031-9155\/56\/6\/022","article-title":"Dosimetric validation of the Acuros XB advanced dose calculation algorithm: fundamental characterization In water","volume":"56","author":"Fogliata","year":"2011","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.meddos.2026.02.002_bib0012","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ejmp.2020.06.021","article-title":"Beam modeling and Beam model commissioning for Monte Carlo dose calculation-based radiation therapy treatment planning: report of AAPM Task Group 157","volume":"47","author":"Ma","year":"2020","journal-title":"Med Phys"},{"issue":"12","key":"10.1016\/j.meddos.2026.02.002_bib0013","doi-asserted-by":"crossref","first-page":"4818","DOI":"10.1118\/1.2795842","article-title":"Report of The AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning","volume":"34","author":"Chetty","year":"2007","journal-title":"Med Phys"},{"issue":"1","key":"10.1016\/j.meddos.2026.02.002_bib0014","doi-asserted-by":"crossref","first-page":"73","DOI":"10.4103\/2228-7477.83522","article-title":"Review of fast Monte Carlo codes for dose calculation In radiation therapy treatment planning","volume":"1","author":"Jabbari","year":"2011","journal-title":"J Med Signals Sens"},{"issue":"4","key":"10.1016\/j.meddos.2026.02.002_bib0015","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1161\/hc0402.102975","article-title":"Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart","volume":"105","author":"Cerqueira","year":"2002","journal-title":"Circulation"},{"issue":"4","key":"10.1016\/j.meddos.2026.02.002_bib0016","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.semradonc.2008.04.001","article-title":"An overview of hypofractionation and introduction to this issue of seminars in radiation oncology","volume":"18","author":"Timmerman","year":"2008","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.meddos.2026.02.002_bib0017","year":"2025"},{"issue":"1","key":"10.1016\/j.meddos.2026.02.002_bib0018","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1118\/1.3671956","article-title":"Stereotactic body radiation therapy: the report of AAPM Task Group 101","volume":"39","author":"Benedict","year":"2012","journal-title":"Med Phys"},{"issue":"11","key":"10.1016\/j.meddos.2026.02.002_bib0019","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1007\/s00392-020-01650-9","article-title":"Radiosurgery for ventricular tachycardia: preclinical and clinical evidence and study design for a German multi-center multi-platform feasibility trial (RAVENTA)","volume":"109","author":"Blanck","year":"2020","journal-title":"Clin Res Cardiol"},{"issue":"8","key":"10.1016\/j.meddos.2026.02.002_bib0020","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1088\/0031-9155\/45\/8\/315","article-title":"DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations","volume":"45","author":"Sempau","year":"2000","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.meddos.2026.02.002_bib0021","unstructured":"Chetty I, Tyagi N, Rosu M et al. April 6-10, 2003. Clinical Implementation, validation and use of the DPM Monte Carlo code for radiotherapy treatment planning. Nuclear mathematical and computational sciences: a century in review, a century anew, Gatlinburg, TN. doi:10.31382\/NSE05-A7368."},{"key":"10.1016\/j.meddos.2026.02.002_bib0022","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1186\/s13014-022-02149-5","article-title":"Monte Carlo simulation of linac using PRIMO","volume":"17","author":"Li","year":"2022","journal-title":"Radiat Oncol"},{"issue":"4","key":"10.1016\/j.meddos.2026.02.002_bib0023","doi-asserted-by":"crossref","first-page":"529","DOI":"10.5603\/RPOR.a2023.0060","article-title":"PRIMO Monte Carlo software as a tool for commissioning of an external beam radiotherapy treatment planning system","volume":"28","author":"Calvo-Ortega","year":"2023","journal-title":"Rep Pract Oncol Radiother"},{"key":"10.1016\/j.meddos.2026.02.002_bib0024","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1007\/s00066-013-0415-1","article-title":"PRIMO: a graphical environment for the Monte Carlo simulation of Varian and Elekta linacs","volume":"189","author":"Rodriguez","year":"2013","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.meddos.2026.02.002_bib0025","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med Phys"},{"issue":"2","key":"10.1016\/j.meddos.2026.02.002_bib0026","doi-asserted-by":"crossref","first-page":"021710","DOI":"10.1118\/1.4860195","article-title":"Comparison of 2D and 3D gamma analyses","volume":"41","author":"Pulliam","year":"2014","journal-title":"Med Phys"},{"key":"10.1016\/j.meddos.2026.02.002_bib0027","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.1118\/1.1598711","article-title":"Evaluation of the gamma dose distribution comparison method","volume":"30","author":"Low","year":"2003","journal-title":"Med Phys"},{"key":"10.1016\/j.meddos.2026.02.002_bib0028","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/S0167-8140(01)00497-2","article-title":"A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation","volume":"62","author":"Depuydt","year":"2002","journal-title":"Radiother Oncol"},{"issue":"5","key":"10.1016\/j.meddos.2026.02.002_bib0029","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.ijrobp.2022.04.040","article-title":"Prospective clinical validation of virtual patient-specific quality assurance of volumetric modulated arc therapy radiation therapy plans","volume":"113","author":"Wall","year":"2022","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.meddos.2026.02.002_bib0030","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ejmp.2017.03.001","article-title":"Challenges in calculation of the gamma index in radiotherapy\u2013towards good practice","volume":"36","author":"Hussein","year":"2017","journal-title":"Phys Med"},{"key":"10.1016\/j.meddos.2026.02.002_bib0031","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1002\/acm2.12444","article-title":"Equivalency of beam scan data collection using a 1D tank and automated couch movements to traditional 3D tank measurements","volume":"201819","author":"Knutson","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.meddos.2026.02.002_bib0032","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.ejmp.2016.11.104","article-title":"Dose calculation algorithm accuracy for small fields in non-homogeneous media: the lung SBRT case","volume":"44","author":"Fogliata","year":"2017","journal-title":"Phys Med"},{"issue":"3","key":"10.1016\/j.meddos.2026.02.002_bib0033","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1002\/pro6.70028","article-title":"Dosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy","volume":"9","author":"Singh","year":"2025","journal-title":"Precis Radiat Oncol"},{"issue":"9","key":"10.1016\/j.meddos.2026.02.002_bib0034","article-title":"Comparison of Acuros (AXB) and anisotropic analytical algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability","volume":"286","author":"Padmanaban","year":"2024","journal-title":"Radiat Oncol"},{"issue":"3","key":"10.1016\/j.meddos.2026.02.002_bib0035","doi-asserted-by":"crossref","first-page":"481","DOI":"10.5603\/RPOR.a2021.0050","article-title":"A comparative analysis of Acuros XB and the analytical anisotropic algorithm for volumetric modulation arc therapy","volume":"26","author":"Srivastava","year":"2021","journal-title":"Rep Pract Oncol Radiother"},{"issue":"6","key":"10.1016\/j.meddos.2026.02.002_bib0036","article-title":"On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment","volume":"103","author":"Fogliata","year":"2011","journal-title":"Radiat Oncol"},{"issue":"5","key":"10.1016\/j.meddos.2026.02.002_bib0037","doi-asserted-by":"crossref","first-page":"051710","DOI":"10.1118\/1.4802216","article-title":"Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer","volume":"40","author":"Han","year":"2013","journal-title":"Med Phys"},{"issue":"8","key":"10.1016\/j.meddos.2026.02.002_bib0038","article-title":"Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated Arc therapy plans","volume":"149","author":"Kroon","year":"2013","journal-title":"Radiat Oncol"},{"issue":"1","key":"10.1016\/j.meddos.2026.02.002_bib0039","doi-asserted-by":"crossref","first-page":"2270","DOI":"10.1038\/s41598-022-05149-3","article-title":"Verification of rebuild-up effect on superficial cardiac lesion of ventricular tachycardia using 3-D printed phantom in volumetric-modulated Arc therapy planning","volume":"12","author":"Roh","year":"2022","journal-title":"Sci Rep"},{"issue":"9","key":"10.1016\/j.meddos.2026.02.002_bib0040","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.clon.2023.04.004","article-title":"A meta-analysis of the efficacy and safety of stereotactic arrhythmia radioablation (STAR) in patients with refractory ventricular tachycardia","volume":"35","author":"Viani","year":"2023","journal-title":"Clin Oncol"}],"container-title":["Medical Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394726000154?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958394726000154?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T11:23:14Z","timestamp":1786101794000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0958394726000154"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"alternative-id":["S0958394726000154"],"URL":"https:\/\/doi.org\/10.1016\/j.meddos.2026.02.002","relation":{},"ISSN":["0958-3947"],"issn-type":[{"value":"0958-3947","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dose calculation algorithm evaluation for cardiac radioablation of ventricular tachycardia","name":"articletitle","label":"Article Title"},{"value":"Medical Dosimetry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.meddos.2026.02.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Inc. on behalf of American Association of Medical Dosimetrists.","name":"copyright","label":"Copyright"}]}}