{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:40:22Z","timestamp":1787510422106,"version":"build-2736575974"},"reference-count":24,"publisher":"IOP Publishing","issue":"7","license":[{"start":{"date-parts":[[2009,5,17]],"date-time":"2009-05-17T00:00:00Z","timestamp":1242518400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2009,5,17]],"date-time":"2009-05-17T00:00:00Z","timestamp":1242518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2009,9,1]]},"DOI":"10.1016\/j.medengphy.2009.04.002","type":"journal-article","created":{"date-parts":[[2009,5,18]],"date-time":"2009-05-18T04:31:47Z","timestamp":1242621107000},"page":"846-851","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Development of a 4-axis load cell used for lumbar interbody load measurements"],"prefix":"10.1088","volume":"31","author":[{"given":"Constantine K.","family":"Demetropoulos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig R.","family":"Morgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dilip K.","family":"Sengupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry N.","family":"Herkowitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2009,5,17]]},"reference":[{"key":"bib1","first-page":"1731","type":"other","article-title":"Analysis of stress distribution in lumbar interbody fusion","volume":"30","author":"Kumar","year":"2005"},{"key":"bib2","first-page":"556","type":"other","article-title":"The importance of the endplate for interbody cages in the lumbar spine","volume":"12","author":"Polikeit","year":"2003"},{"key":"bib3","first-page":"2558","type":"other","article-title":"Finite element analysis of anterior lumbar interbody fusion: threaded cylindrical cage and pedicle screw fixation","volume":"32","author":"Kim","year":"2007"},{"key":"bib4","first-page":"E992","type":"other","article-title":"Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion\u2014a finite element study","volume":"31","author":"Vadapalli","year":"2006"},{"key":"bib5","first-page":"442","type":"other","article-title":"An in vitro biomechanical investigation: variable positioning of leopard carbon fiber interbody cages","volume":"21","author":"Quigley","year":"2008"},{"key":"bib6","first-page":"28","type":"other","article-title":"Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support","volume":"8","author":"Chen","year":"2007"},{"key":"bib7","first-page":"253","type":"other","article-title":"Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants","volume":"54","author":"Graichen","year":"2007"},{"key":"bib8","first-page":"2139","type":"other","article-title":"In vivo glenohumeral contact forces\u2013measurements in the first patient 7 months postoperatively","volume":"40","author":"Bergmann","year":"2007"},{"key":"bib9","first-page":"1744","type":"other","article-title":"A multiaxial force-sensing implantable tibial prosthesis","volume":"39","author":"Kirking","year":"2006"},{"key":"bib10","first-page":"2595","type":"other","article-title":"Real-time in vivo loading in the lumbar spine. Part 1. Interbody implant: load cell design and preliminary results","volume":"25","author":"Ledet","year":"2000"},{"key":"bib11","first-page":"85","type":"other","article-title":"Direct real-time measurement of in vivo forces in the lumbar spine","volume":"5","author":"Ledet","year":"2005"},{"key":"bib12","first-page":"347","type":"other","article-title":"In vivo measurement of implant loads in a patient with a fractured vertebral body","volume":"4","author":"Rohlmann","year":"1995"},{"key":"bib13","first-page":"580","type":"other","article-title":"An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column","volume":"29","author":"Rohlmann","year":"2007"},{"key":"bib14","first-page":"147","type":"other","article-title":"Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month","volume":"23","author":"Rohlmann","year":"2008"},{"key":"bib15","first-page":"1170","type":"other","article-title":"Loads on a telemeterized vertebral body replacement measured in two patients","volume":"33","author":"Rohlmann","year":"2008"},{"key":"bib16","first-page":"2981","type":"other","article-title":"2000 Volvo Award winner in biomechanical studies: monitoring in vivo implant loads with a telemeterized internal spinal fixation device","volume":"25","author":"Rohlmann","year":"2000"},{"key":"bib17","first-page":"1077","type":"other","article-title":"In vivo measurements of intradiscal pressure discometry: a method for the determination of pressure in the lower lumbar discs","volume":"46","author":"Nachemson","year":"1964"},{"key":"bib18","first-page":"755","type":"other","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999"},{"key":"bib19","first-page":"539","type":"other","article-title":"Comparison of loads on internal spinal fixation devices measured in vitro and in vivo","volume":"19","author":"Rohlmann","year":"1997"},{"key":"bib20","first-page":"485","type":"other","article-title":"In vitro load measurement using an instrumented spinal fixation device","volume":"18","author":"Rohlmann","year":"1996"},{"key":"bib21","first-page":"636","type":"other","article-title":"Is it possible to simulate physiologic loading conditions by applying pure moments? A comparison of in vivo and in vitro load components in an internal fixator","volume":"26","author":"Wilke","year":"2001"},{"key":"bib22","type":"other"},{"key":"bib23","first-page":"021009","type":"other","article-title":"Design and calibration of load sensing orthopaedic implants","volume":"130","author":"Bergmann","year":"2008"},{"key":"bib24","type":"other"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453309000940?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453309000940?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.04.002","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.04.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.04.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.04.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T10:58:44Z","timestamp":1769079524000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.04.002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,17]]},"references-count":24,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2009,5,17]]},"published-print":{"date-parts":[[2009,9,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2009.04.002","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,17]]},"assertion":[{"value":"Development of a 4-axis load cell used for lumbar interbody load measurements","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2009 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2008-09-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2009-04-20","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2009-05-17","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}