{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T20:11:18Z","timestamp":1791058278605,"version":"4.1.0"},"reference-count":29,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2009,12,4]],"date-time":"2009-12-04T00:00:00Z","timestamp":1259884800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2009,12,4]],"date-time":"2009-12-04T00:00:00Z","timestamp":1259884800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2010,3,1]]},"DOI":"10.1016\/j.medengphy.2009.10.013","type":"journal-article","created":{"date-parts":[[2009,12,5]],"date-time":"2009-12-05T04:31:09Z","timestamp":1259987469000},"page":"111-118","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":46,"title":["Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis"],"prefix":"10.1088","volume":"32","author":[{"given":"Zaher","family":"Kharboutly","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valerie","family":"Deplano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Bertrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cecile","family":"Legallais","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2009,12,4]]},"reference":[{"key":"bib1","first-page":"1089","type":"other","article-title":"Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula","volume":"275","author":"Brescia","year":"1966"},{"key":"bib2","first-page":"640","type":"other","article-title":"A prospective study of end-to-side vs. side-to-side arteriovenous fistulas for haemodialysis","volume":"71","author":"Wedgwood","year":"1984"},{"key":"bib3","first-page":"1684","type":"other","article-title":"Effect of haemodynamic variables on surgically created arteriovenous fistula flow","volume":"12","author":"Anadol","year":"1997"},{"key":"bib4","first-page":"329","type":"other","article-title":"Tailoring the initial vascular access for dialysis patients","volume":"62","author":"Konner","year":"2002"},{"key":"bib5","first-page":"1057","type":"other","article-title":"Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access","volume":"17","author":"Corpataux","year":"2002"},{"key":"bib6","first-page":"829","type":"other","article-title":"Brachial artery thrombosis due to haemodialysis arteriovenous fistula","volume":"21","author":"Keuter","year":"2006"},{"key":"bib7","first-page":"317","type":"other","article-title":"Clinical and instrumental surveillance of the arteriovenous fistula","volume":"21","author":"Quarello","year":"2004"},{"key":"bib8","first-page":"1542","type":"other","article-title":"Vascular access: care and monitoring of function","volume":"16","author":"Vanholder","year":"2001"},{"key":"bib9","first-page":"357","type":"other","article-title":"Angioaccess for haemodialysis","volume":"12","author":"Konner","year":"1997"},{"key":"bib10","first-page":"103","type":"other","article-title":"Management of suspected hemodialysis graft dysfunction: usefulness of diagnostic us","volume":"222","author":"Dumars","year":"2002"},{"key":"bib11","first-page":"1436","type":"other","article-title":"Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: initial experience","volume":"186","author":"Zhang","year":"2006"},{"key":"bib12","first-page":"284","type":"other","article-title":"Stenosis detection with MR angiography and digital subtraction angiography in dysfunctional hemodialysis access fistulas and grafts","volume":"234","author":"Froger","year":"2005"},{"key":"bib13","first-page":"368","type":"other","article-title":"Spiral computed tomography in evaluation of arteriovenous fistula for hemodialysis. Preliminary report","volume":"13","author":"Wierzbicki","year":"2002"},{"key":"bib14","first-page":"57","type":"other","article-title":"Three-dimensional contrast-enhanced magnetic resonance angiography 37D CE_MRA in the evaluation of hemodialysis access complications, and the condition of central veins in patients who are candidates for hemodialysis access","volume":"17","author":"Paksoy","year":"2004"},{"key":"bib15","first-page":"284","type":"other","article-title":"Computational fluid dynamics of a vascular access case for hemodialysis","volume":"123","author":"Ene-Iordache","year":"2001"},{"key":"bib16","first-page":"423","type":"other","article-title":"Radial artery wall shear stress evaluation in patients with arteriovenous fistula for hemodialysis access","volume":"40","author":"Remuzzi","year":"2003"},{"key":"bib17","first-page":"95","type":"other","article-title":"Radial artery remodeling in response to shear stress increase within arteriovenous fistula for hemodialysis access","volume":"10","author":"Ene-Iordache","year":"2003"},{"key":"bib18","first-page":"999","type":"other","article-title":"Investigations into the relationship between hemodynamics and vascular alterations in an established arteriovenous fistula","volume":"29","author":"Kharboutly","year":"2007"},{"key":"bib19","first-page":"1142","type":"other","article-title":"Hemodynamics and complications encountered with arteriovenous fistulas and grafts as vascular access for hemodialysis: a review","volume":"33","author":"Van Tricht","year":"2005"},{"key":"bib20","first-page":"226","type":"other","article-title":"Validation of numerical simulation with PIV measurements for two anastomosis models","volume":"30","author":"Zhang","year":"2008"},{"key":"bib21","first-page":"39","type":"other","article-title":"Simulation of blood flow by a hydrodynamic generator","volume":"13","author":"Issartier","year":"1978"},{"key":"bib22","first-page":"118","type":"other","article-title":"Sites of stenosis in AV fistulae for haemodialysis access","volume":"14","author":"Sivanesan","year":"1999"},{"key":"bib23","first-page":"109","type":"other","article-title":"Experimental and numerical studies on the starting effect on the secondary flow in a bend","volume":"574","author":"Boiron","year":"2007"},{"key":"bib24","first-page":"11","type":"other","article-title":"Experimental analysis of unsteady flows through a stenosis","volume":"31","author":"Siouffi","year":"1998"},{"key":"bib25","first-page":"1081","type":"other","article-title":"Experimental and numerical study of pulsatile flows through stenosis: wall shear stress analysis","volume":"32","author":"Deplano","year":"1999"},{"key":"bib26","first-page":"611","type":"other","article-title":"Cost analysis of ongoing care of patients with end-stage renal disease: the impact of dialysis modality and dialysis access","volume":"40","author":"Lee","year":"2002"},{"key":"bib27","first-page":"1413","type":"other","article-title":"Why don\u2019t fistulas mature?","volume":"70","author":"Dixon","year":"2006"},{"key":"bib28","first-page":"336","type":"other","article-title":"Intimal hyperplasia in vascular grafts","volume":"19","author":"Lemson","year":"2000"},{"key":"bib29","first-page":"332","type":"other","article-title":"Early arteriovenous fistula failure: a logical proposal for when and how to intervene","volume":"1","author":"Asif","year":"2006"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S135045330900229X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S135045330900229X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.10.013","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.10.013\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.10.013\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.10.013\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:47:15Z","timestamp":1769093235000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2009.10.013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12,4]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2009,12,4]]},"published-print":{"date-parts":[[2010,3,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2009.10.013","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,12,4]]},"assertion":[{"value":"Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2009 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2009-05-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2009-10-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2009-12-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}