{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T21:05:00Z","timestamp":1791234300972,"version":"4.1.0"},"reference-count":32,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2015,7,27]],"date-time":"2015-07-27T00:00:00Z","timestamp":1437955200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2015,7,27]],"date-time":"2015-07-27T00:00:00Z","timestamp":1437955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100004543","name":"China Scholarship Council","doi-asserted-by":"crossref","award":["2011629034"],"award-info":[{"award-number":["2011629034"]}],"id":[{"id":"10.13039\/501100004543","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2015,9,1]]},"DOI":"10.1016\/j.medengphy.2015.06.001","type":"journal-article","created":{"date-parts":[[2015,7,27]],"date-time":"2015-07-27T17:36:12Z","timestamp":1438018572000},"page":"862-869","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":33,"title":["Failure location prediction by finite element analysis for an additive manufactured mandible implant"],"prefix":"10.1088","volume":"37","author":[{"given":"Jinxing","family":"Huo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Per","family":"D\u00e9rand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars-Erik","family":"R\u00e4nnar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Micha\u00e9l","family":"Hirsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. Kristofer","family":"Gamstedt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2015,7,27]]},"reference":[{"key":"bib0001","first-page":"187","type":"other","article-title":"A selective laser sintering guide for transferring a virtual plan to real time surgery in composite mandibular reconstruction with free fibula osseous flaps","volume":"38","author":"Leiggener","year":"2009"},{"key":"bib0002","first-page":"71","type":"other","article-title":"Fibula free flap: a new method of mandible reconstruction","volume":"84","author":"Hidalgo","year":"1989"},{"key":"bib0003","first-page":"43","type":"other","article-title":"Additive manufacturing for microvascular reconstruction of the mandible in 20 patients","volume":"40","author":"Lethaus","year":"2012"},{"key":"bib0004","first-page":"393","type":"other","article-title":"Anatomical shape analysis of the mandible in Caucasian and Chinese for the production of preformed mandible reconstruction plates","volume":"39","author":"Metzger","year":"2011"},{"key":"bib0005","first-page":"424","type":"other","article-title":"Biomechanical analysis of titanium plate systems in mandibular condyle fractures: a systematized literature review","volume":"27","author":"Costa","year":"2012"},{"key":"bib0006","first-page":"325","type":"other","article-title":"Use of finite element analysis in presurgical planning: treatment of mandibular fractures","volume":"177","author":"Kavanagh","year":"2008"},{"key":"bib0007","first-page":"264","type":"other","article-title":"Finite element analysis of customized reconstruction plates for mandibular continuity defect therapy","volume":"47","author":"Narra","year":"2014"},{"key":"bib0008","first-page":"73","type":"other","article-title":"Optimal design of an individual endoprosthesis for the reconstruction of extensive mandibular defects with finite element analysis","volume":"42","author":"Li","year":"2014"},{"key":"bib0009","first-page":"973","type":"other","article-title":"Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures","volume":"67","author":"Lovald","year":"2009"},{"key":"bib0010","first-page":"170","type":"other","article-title":"Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models","volume":"30","author":"Nagasao","year":"2002"},{"key":"bib0011","first-page":"335","type":"other","article-title":"Comparative finite element analysis of the biomechanical stability of 2.0 fixation plates in atrophic mandibular fractures","volume":"71","author":"Vajgel","year":"2013"},{"key":"bib0012","first-page":"91","type":"other","article-title":"Experimental and finite element study of a human mandible","volume":"28","author":"Vollmer","year":"2000"},{"key":"bib0013","first-page":"137","type":"other","article-title":"Imaging, virtual planning, design, and production of patient-specific implants and clinical validation in craniomaxillofacial surgery","volume":"5","author":"D\u00e9rand","year":"2012"},{"key":"bib0014","first-page":"894","type":"other","article-title":"Evaluation of two iterative techniques for reducing metal artifacts in computed tomography","volume":"259","author":"Boas","year":"2011"},{"key":"bib0015","first-page":"740","type":"other","article-title":"Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate","volume":"18","author":"Cronsk\u00e4r","year":"2015"},{"key":"bib0016","first-page":"1712","type":"other","article-title":"Does screw-bone interface modelling matter in finite element analysis?","volume":"45","author":"MacLeod","year":"2012"},{"key":"bib0017","first-page":"700","type":"other","article-title":"Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement","volume":"57","author":"Misch","year":"1999"},{"key":"bib0018","type":"other"},{"key":"bib0019","first-page":"231","type":"other","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Niinomi","year":"1998"},{"key":"bib0020","first-page":"444","type":"other","article-title":"A modified method for assigning material properties to FE models of bones","volume":"30","author":"Helgason","year":"2008"},{"key":"bib0021","first-page":"1903","type":"other","article-title":"Mandibular stiffness in humans: numerical predictions","volume":"39","author":"Ichim","year":"2006"},{"key":"bib0022","first-page":"252","type":"other","article-title":"Variations in cortical material properties throughout the human dentate mandible","volume":"120","author":"Schwartz-Dabney","year":"2003"},{"key":"bib0023","first-page":"591","type":"other","article-title":"Comparison of stress distribution around vertical and angled implants with finite element analysis","volume":"27","author":"Canay","year":"1996"},{"key":"bib0024","first-page":"675","type":"other","article-title":"Three-dimensional finite element stress analysis of a cuneiform-geometry implant","volume":"18","author":"Cruz","year":"2003"},{"key":"bib0025","first-page":"316","type":"other","article-title":"A three-dimensional finite element model of the mandible including the TMJ and its application to stress analysis in the TMJ during clenching","volume":"16","author":"Tanaka","year":"1994"},{"key":"bib0026","first-page":"81","type":"other","article-title":"The human masticatory system from a biomechanical perspective: a review","volume":"6","author":"Pileicikiene","year":"2004"},{"key":"bib0027","first-page":"828","type":"other","article-title":"Numerical estimation of bone density and elastic constants distribution in a human mandible","volume":"40","author":"Reina","year":"2007"},{"key":"bib0028","first-page":"55","type":"other","article-title":"Internal organization in the human jaw muscles","volume":"5","author":"Hannam","year":"1994"},{"key":"bib0029","first-page":"193","type":"other","article-title":"Adaquate fixation of plates for stability during mandibular reconstruction","volume":"34","author":"Kimura","year":"2006"},{"key":"bib0030","first-page":"365","type":"other","article-title":"Production of customized hip stem prostheses \u2013 a comparison between conventional machining and electron beam melting (EBM)","volume":"19","author":"Cronsk\u00e4r","year":"2013"},{"key":"bib0031","first-page":"20","type":"other","article-title":"Microstructure and mechanical behavior of Ti-6Al-4\u00a0V produced by rapid-layer manufacturing, for biomedical applications","volume":"2","author":"Murr","year":"2009"},{"key":"bib0032","author":"Slattery","year":"2008","type":"other"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453315001496?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453315001496?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2015.06.001","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2015.06.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2015.06.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2015.06.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:50:16Z","timestamp":1769093416000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2015.06.001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7,27]]},"references-count":32,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2015,7,27]]},"published-print":{"date-parts":[[2015,9,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2015.06.001","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,27]]},"assertion":[{"value":"Failure location prediction by finite element analysis for an additive manufactured mandible implant","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2015 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2014-11-27","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-06-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-07-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}