{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T12:05:37Z","timestamp":1774267537384,"version":"3.50.1"},"reference-count":24,"publisher":"IOP Publishing","issue":"11","license":[{"start":{"date-parts":[[2016,9,16]],"date-time":"2016-09-16T00:00:00Z","timestamp":1473984000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2016,9,16]],"date-time":"2016-09-16T00:00:00Z","timestamp":1473984000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100004738","name":"E-Da Hospital","doi-asserted-by":"publisher","award":["EDAHI-102001"],"award-info":[{"award-number":["EDAHI-102001"]}],"id":[{"id":"10.13039\/501100004738","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Ministry of Science and Technology, ROC","award":["102-2221-E-020-012"],"award-info":[{"award-number":["102-2221-E-020-012"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2016,11,1]]},"DOI":"10.1016\/j.medengphy.2016.08.009","type":"journal-article","created":{"date-parts":[[2016,9,17]],"date-time":"2016-09-17T18:16:19Z","timestamp":1474136179000},"page":"1314-1321","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":18,"title":["Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones"],"prefix":"10.1088","volume":"38","author":[{"given":"Yung-Chuan","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chih-Kun","family":"Hsiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji-Sih","family":"Ciou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi-Jung","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2615-7201","authenticated-orcid":true,"given":"Yuan-Kun","family":"Tu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2016,9,16]]},"reference":[{"key":"bib0001","first-page":"155","type":"other","article-title":"Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man","volume":"52","author":"Albrektsson","year":"1981"},{"key":"bib0002","first-page":"101","type":"other","article-title":"Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit","volume":"50","author":"Eriksson","year":"1983"},{"key":"bib0003","first-page":"563","type":"other","article-title":"A study of the effects of high-speed rotary instruments on bone repair in dogs","volume":"17","author":"Costich","year":"1964"},{"key":"bib0004","first-page":"297","type":"other","article-title":"Temperatures measured in human cortical bone when drilling","volume":"54","author":"Matthews","year":"1972"},{"key":"bib0005","first-page":"267","type":"other","article-title":"Temperature elevations in orthopaedic cutting operations","volume":"15","author":"Krause","year":"1982"},{"key":"bib0006","first-page":"212","type":"other","article-title":"Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography","volume":"7","author":"Watanabe","year":"1992"},{"key":"bib0007","first-page":"1315","type":"other","article-title":"Measurements of shaft speed while drilling through bone","volume":"53","author":"Abouzgia","year":"1995"},{"key":"bib0008","first-page":"394","type":"other","article-title":"Effect of drill speed on bone temperature","volume":"25","author":"Abouzgia","year":"1996"},{"key":"bib0009","first-page":"35","type":"other","article-title":"The effect of speed, pressure, and time on bone temperature during the drilling of implant sites","volume":"11","author":"Brisman","year":"1996"},{"key":"bib0010","first-page":"263","type":"other","article-title":"Temperature changes in bovine mandibular bone during implant site preparation: an assessment using infrared thermography","volume":"24","author":"Benington","year":"1996"},{"key":"bib0011","first-page":"186","type":"other","article-title":"Heat generation during implant site preparation: an in vitro study","volume":"12","author":"Cordioli","year":"1997"},{"key":"bib0012","first-page":"269","type":"other","article-title":"Finite element simulations of bone temperature rise during bone drilling based on a bone analog","volume":"33","author":"Tu","year":"2013"},{"key":"bib0013","first-page":"335","type":"other","article-title":"The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability","volume":"19","author":"Ercoli","year":"2004"},{"key":"bib0014","first-page":"e188","type":"other","article-title":"Comparison of Cortical bone drilling induced heat production among common drilling tools","volume":"29","author":"Palmisano","year":"2015"},{"key":"bib0015","first-page":"265","type":"other","article-title":"Heat production by 3 implant drill systems after repeated drilling and sterilization","volume":"64","author":"Chacon","year":"2006"},{"key":"bib0016","first-page":"28","type":"other","article-title":"An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling","volume":"112","author":"Misic","year":"2011"},{"key":"bib0017","first-page":"1221","type":"other","article-title":"Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study","volume":"33","author":"Karaca","year":"2011"},{"key":"bib0018","first-page":"313","type":"other","article-title":"Cortical bone drilling and thermal osteonecrosis","volume":"27","author":"Augustin","year":"2012"},{"key":"bib0019","first-page":"302","type":"other","article-title":"Temperature effects in the drilling of human and bovine bone","volume":"92","author":"Hillery","year":"1999"},{"key":"bib0020","first-page":"1510","type":"other","article-title":"An experimental investigation on thermal exposure during bone drilling","volume":"34","author":"Lee","year":"2012"},{"key":"bib0021","first-page":"13","type":"other","article-title":"Influence of drill parameters on bone temperature and necrosis: A FEM modelling and in vitro experiments","volume":"60","author":"Sezek","year":"2012"},{"key":"bib0022","first-page":"131","type":"other","article-title":"Heat generated by dental implant drills during osteotomy\u2013a review","volume":"14","author":"Mishra","year":"2014"},{"key":"bib0023","first-page":"83","type":"other","article-title":"Effects of drill cooling and bone structure on imz implant fixation","volume":"8","author":"Haider","year":"1993"},{"key":"bib0024","first-page":"71","type":"other","article-title":"Thermal ostennecrosis and bone drilling parameters revisited","volume":"128","author":"Agugstin","year":"2008"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453316301862?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453316301862?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2016.08.009","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2016.08.009\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2016.08.009\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2016.08.009\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:50:17Z","timestamp":1769093417000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2016.08.009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,16]]},"references-count":24,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2016,9,16]]},"published-print":{"date-parts":[[2016,11,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2016.08.009","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9,16]]},"assertion":[{"value":"Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2016 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2015-10-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-08-23","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-09-16","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}