{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T17:58:10Z","timestamp":1791050290996,"version":"4.1.0"},"reference-count":26,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2017,4,24]],"date-time":"2017-04-24T00:00:00Z","timestamp":1492992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2017,4,24]],"date-time":"2017-04-24T00:00:00Z","timestamp":1492992000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2017,7,1]]},"DOI":"10.1016\/j.medengphy.2017.04.001","type":"journal-article","created":{"date-parts":[[2017,4,24]],"date-time":"2017-04-24T09:15:22Z","timestamp":1493025322000},"page":"25-33","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":23,"title":["Notched K-wire for low thermal damage bone drilling"],"prefix":"10.1088","volume":"45","author":[{"given":"Yao","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry","family":"Belmont","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiwen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce","family":"Tai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Holmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5338-5467","authenticated-orcid":true,"given":"Albert","family":"Shih","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2017,4,24]]},"reference":[{"key":"bib0001","first-page":"1","type":"other","article-title":"One century of Kirschner wires and Kirschner wire insertion techniques: a historical review","volume":"76","author":"Franssen","year":"2010"},{"key":"bib0002","first-page":"289","type":"other","article-title":"The biomechanical efficacy of an oscillating K-wire driver","volume":"29","author":"Nichter","year":"1992"},{"key":"bib0003","first-page":"153","type":"other","article-title":"Fixation of Kirschner wires: a comparison between hammering and drilling k-wires into ribs of pigs","volume":"29","author":"Wassenaar","year":"2006"},{"key":"bib0004","first-page":"355","type":"other","article-title":"The thermal effects of Kirschner wire fixation on small bones","volume":"24","author":"Khanna","year":"1990"},{"key":"bib0005","first-page":"484","type":"other","article-title":"The design and function of surgical drills and K-wires","volume":"18","author":"Karmani","year":"2004"},{"key":"bib0006","first-page":"15","type":"other","article-title":"Drilling of bone: A comprehensive review","volume":"4","author":"Pandey","year":"2013"},{"key":"bib0007","author":"Liu","year":"2015","type":"other"},{"key":"bib0008","author":"Tai","year":"2014","type":"other"},{"key":"bib0009","author":"Belmont","year":"2014","type":"other"},{"key":"bib0010","first-page":"313","type":"other","article-title":"Cortical bone drilling and thermal osteonecrosis","volume":"27","author":"Augustin","year":"2012"},{"key":"bib0011","first-page":"71","type":"other","article-title":"Thermal osteonecrosis and bone drilling parameters revisited","volume":"128","author":"Augustin","year":"2008"},{"key":"bib0012","first-page":"25","type":"other","article-title":"Effects of various drilling parameters on bone during implantology: an in vitro experimental study","volume":"15","author":"Karaca","year":"2013"},{"key":"bib0013","first-page":"1510","type":"other","article-title":"An experimental investigation on thermal exposure during bone drilling","volume":"34","author":"Lee","year":"2012"},{"key":"bib0014","first-page":"1221","type":"other","article-title":"Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study","volume":"33","author":"Karaca","year":"2011"},{"key":"bib0015","first-page":"1211","type":"other","article-title":"A new thermal model for bone drilling with applications to orthopaedic surgery","volume":"33","author":"Lee","year":"2011"},{"key":"bib0016","first-page":"234","type":"other","article-title":"Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone","volume":"33","author":"Alam","year":"2011"},{"key":"bib0017","first-page":"215","type":"other","article-title":"Hammering versus drilling of sharp and obtuse trocar-point K-wires","volume":"34","author":"Franssen","year":"2009"},{"key":"bib0018","first-page":"188","type":"other","article-title":"Comparison of cortical bone drilling induced heat production among common drilling tools","volume":"29","author":"Palmisano","year":"2015"},{"key":"bib0019","first-page":"855","type":"other","article-title":"Numerical evaluation of sequential bone drilling strategies based on thermal damage","volume":"9","author":"Tai","year":"2015"},{"key":"bib0020","first-page":"137","type":"other","article-title":"Drilling efficiency and temperature elevation of three types of Kirschner-wire point","volume":"84","author":"Piska","year":"2002"},{"key":"bib0021","type":"other"},{"key":"bib0022","first-page":"394","type":"other","article-title":"Effect of drill speed on bone temperature","volume":"25","author":"Abouzgia","year":"1996"},{"key":"bib0023","first-page":"35","type":"other","article-title":"The effect of speed, pressure, and time on bone temperature during the drilling of implant sites","volume":"11","author":"Brisman","year":"1996"},{"key":"bib0024","first-page":"242","type":"other","article-title":"Distribution of heat generated in drilling","volume":"71","author":"Schmidt","year":"1949"},{"key":"bib0025","first-page":"653","type":"other","article-title":"A review of the experimental techniques for the measurement of heat and temperatures generated in some manufacturing processes and tribology","volume":"34","author":"Komanduri","year":"2001"},{"key":"bib0026","first-page":"12","type":"other","article-title":"Variations of box plots","volume":"32","author":"McGill","year":"1978"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453317301029?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453317301029?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.04.001","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.04.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.04.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.04.001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:01:29Z","timestamp":1769094089000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.04.001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,24]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,4,24]]},"published-print":{"date-parts":[[2017,7,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2017.04.001","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,24]]},"assertion":[{"value":"Notched K-wire for low thermal damage bone drilling","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2017 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2016-03-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-04-01","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-04-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}