{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T06:21:09Z","timestamp":1769149269142,"version":"3.49.0"},"reference-count":21,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000738","name":"U.S. Department of Veterans Affairs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000738","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000138","name":"U.S. Department of Education","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000138","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2017,11,1]]},"DOI":"10.1016\/j.medengphy.2017.07.002","type":"journal-article","created":{"date-parts":[[2017,8,14]],"date-time":"2017-08-14T06:01:04Z","timestamp":1502690464000},"page":"22-27","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Second generation prototype of a variable stiffness transverse plane adapter for a lower limb prosthesis"],"prefix":"10.1088","volume":"49","author":[{"given":"Corey","family":"Pew","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9527-9590","authenticated-orcid":true,"given":"Glenn K.","family":"Klute","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","reference":[{"key":"bib0001","first-page":"1","type":"other","article-title":"Transtibial energy-storage-and-return prosthetic devices: a review of energy concepts and a proposed nomenclature","volume":"39","author":"Hafner","year":"2002"},{"key":"bib0002","first-page":"50","type":"other","article-title":"Gait analysis in prosthetics: opinions, ideas and conclusions","volume":"26","author":"Rietman","year":"2002"},{"key":"bib0003","first-page":"555","type":"other","article-title":"A systematic literature review of the effect of different prosthetic components on human functioning with a lower-limb prosthesis","volume":"41","author":"van der Linde","year":"2004"},{"key":"bib0004","first-page":"289","type":"other","article-title":"Video task analysis of turning during activities of daily living","volume":"25","author":"Glaister","year":"2007"},{"key":"bib0005","first-page":"827","type":"other","article-title":"Mechanical and metabolic requirements for active lateral stabilization in human walking","volume":"37","author":"Donelan","year":"2004"},{"key":"bib0006","first-page":"3085","type":"other","article-title":"Does a torsion adapter improve functional mobility, pain, and fatigue in patients with transtibial amputation?","author":"Segal","year":"2014"},{"key":"bib0007","first-page":"34","type":"other","article-title":"The effects of increased prosthetic ankle motions on the gait of persons with bilateral transtibial amputations","volume":"89","author":"Su","year":"2010"},{"key":"bib0008","first-page":"114","type":"other","article-title":"Functional analysis of the UC-BL shank axial rotation device","volume":"1","author":"Lamoureux","year":"1977"},{"key":"bib0009","first-page":"73","type":"other","article-title":"Comparison of human turning gait with the mechanical performance of lower limb prosthetic transverse rotation adapters","volume":"29","author":"Flick","year":"2005"},{"key":"bib0010","first-page":"35001","type":"other","article-title":"Design of lower limb prosthesis transverse plane adaptor with variable stiffness","volume":"9","author":"Pew","year":"2015"},{"key":"bib0011","first-page":"104","type":"other","article-title":"Pilot testing of a variable stiffness transverse plane adapter for lower limb amputees","volume":"51","author":"Pew","year":"2017"},{"key":"bib0012","first-page":"35","type":"other","article-title":"The biomechanical effects of the inclusion of a torque absorber on trans\u2010femoral amputee gait, a pilot study","volume":"26","author":"Linden","year":"2002"},{"key":"bib0013","author":"Oberg","year":"2012","type":"other"},{"key":"bib0014","first-page":"1593","type":"other","article-title":"Effects of prosthetic mass and mass distribution on kinematics and energetics of prosthetic gait: a systematic review","volume":"80","author":"Selles","year":"1999"},{"key":"bib0015","first-page":"162","type":"other","article-title":"Mass and mass distribution of below-knee prostheses: effect on gait efficacy and self-selected walking speed","volume":"79","author":"Lehmann","year":"1998"},{"key":"bib0016","first-page":"9","type":"other","article-title":"The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees","volume":"21","author":"Gailey","year":"1997"},{"key":"bib0017","first-page":"1865","type":"other","article-title":"The effects of added prosthetic mass on physiologic responses and stride frequency during multiple speeds of walking in persons with transtibial amputation","volume":"84","author":"Lin-Chan","year":"2003"},{"key":"bib0018","first-page":"552","type":"other","article-title":"Mechanical behavior of the human ankle in the transverse plane while turning","volume":"15","author":"Glaister","year":"2007"},{"key":"bib0019","author":"Winter","year":"1991","type":"other"},{"key":"bib0020","first-page":"444","type":"other","article-title":"Kinematic variability and local dynamic stability of upper body motions when walking at different speeds","volume":"39","author":"Dingwell","year":"2006"},{"key":"bib0021","first-page":"282","type":"other","article-title":"Influence of walking speed on gait parameters","volume":"7","author":"Kirtley","year":"1985"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453317301972?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453317301972?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.07.002","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.07.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.07.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.07.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:01:40Z","timestamp":1769094100000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2017.07.002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,1]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,11,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2017.07.002","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,1]]},"assertion":[{"value":"Second generation prototype of a variable stiffness transverse plane adapter for a lower limb prosthesis","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2017 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2017-05-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-07-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}