{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T14:55:02Z","timestamp":1789570502485,"version":"build-2803163510"},"reference-count":91,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2019,9,3]],"date-time":"2019-09-03T00:00:00Z","timestamp":1567468800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,9,3]],"date-time":"2019-09-03T00:00:00Z","timestamp":1567468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2019,12,1]]},"DOI":"10.1016\/j.medengphy.2019.08.002","type":"journal-article","created":{"date-parts":[[2019,9,3]],"date-time":"2019-09-03T17:09:45Z","timestamp":1567530585000},"page":"1-12","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":65,"title":["Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges"],"prefix":"10.1088","volume":"74","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5255-1486","authenticated-orcid":true,"given":"Robert J.","family":"Cooper","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruth K.","family":"Wilcox","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison C.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2019,9,3]]},"reference":[{"key":"bib0001","first-page":"S6","type":"other","article-title":"The impact of osteoarthritis: implications for research","volume":"427","author":"Buckwalter","year":"2004"},{"key":"bib0002","first-page":"879","type":"other","article-title":"Review of the biomechanics and biotribology of osteochondral grafts used for surgical interventions in the knee","volume":"229","author":"Bowland","year":"2015"},{"key":"bib0003","article-title":"The risk of symptomatic knee osteoarthritis after arthroscopic meniscus repair vs partial meniscectomy vs the general population","author":"Persson","year":"2017","type":"other"},{"key":"bib0004","first-page":"63","type":"other","article-title":"Anterior cruciate ligament graft choices","volume":"4","author":"Macaulay","year":"2012"},{"key":"bib0005","first-page":"3004","type":"other","article-title":"Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator","volume":"48","author":"Liu","year":"2015"},{"key":"bib0006","type":"other","article-title":"Recent advances in computational mechanics of the human knee joint","volume":"2013","author":"Kazemi","year":"2013"},{"key":"bib0007","first-page":"21415","type":"other","article-title":"A novel method to simulate the progression of collagen degeneration of cartilage in the knee: data from the osteoarthritis initiative","volume":"6","author":"Mononen","year":"2016"},{"key":"bib0008","first-page":"2458","type":"other","article-title":"Computational biomechanics of articular cartilage of human knee joint: effect of osteochondral defects","volume":"42","author":"Shirazi","year":"2009"},{"key":"bib0009","first-page":"37538","type":"other","article-title":"Quantitative evaluation of the mechanical risks caused by focal cartilage defects in the knee","volume":"6","author":"Ven\u00e4l\u00e4inen","year":"2016"},{"key":"bib0010","type":"other","article-title":"The effects of geometric uncertainties on computational modelling of knee biomechanics","volume":"4","author":"Meng","year":"2017"},{"key":"bib0011","first-page":"1356","type":"other","article-title":"Influence of meniscus shape in the cross sectional plane on the knee contact mechanics","volume":"48","author":"\u0141uczkiewicz","year":"2015"},{"key":"bib0012","first-page":"1193","type":"other","article-title":"Computational investigation of the time-dependent contact behaviour of the human tibiofemoral joint under body weight","volume":"228","author":"Meng","year":"2014"},{"key":"bib0013","first-page":"287","type":"other","article-title":"Individuals with patellofemoral pain exhibit greater patellofemoral joint stress: a finite element analysis study","volume":"19","author":"Farrokhi","year":"2011"},{"key":"bib0014","first-page":"176","type":"other","article-title":"Biomechanics of knee joint\u2014a review","volume":"10","author":"Madeti","year":"2015"},{"key":"bib0015","first-page":"1","type":"other","article-title":"The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint","volume":"65","author":"Beidokhti","year":"2017"},{"key":"bib0016","first-page":"117","type":"other","article-title":"Combined measurement and modeling of specimen-specific knee mechanics for healthy and ACL-deficient conditions","volume":"57","author":"Ali","year":"2017"},{"key":"bib0017","first-page":"34","type":"other","article-title":"The effect of fixed charge density and cartilage swelling on mechanics of knee joint cartilage during simulated gait","volume":"61","author":"R\u00e4s\u00e4nen","year":"2017"},{"key":"bib0018","first-page":"949","type":"other","article-title":"Segmentation accuracy of long bones","volume":"36","author":"den Broeck","year":"2014"},{"key":"bib0019","first-page":"1502","type":"other","article-title":"Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis","volume":"17","author":"Mootanah","year":"2014"},{"key":"bib0020","first-page":"62","type":"other","article-title":"Where does meniscal damage progress most rapidly? An analysis using three-dimensional shape models on data from the Osteoarthritis Initiative","volume":"26","author":"Dube","year":"2018"},{"key":"bib0021","first-page":"1686","type":"other","article-title":"A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint","volume":"39","author":"Pena","year":"2006"},{"key":"bib0022","first-page":"498","type":"other","article-title":"Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics","volume":"20","author":"Pena","year":"2005"},{"key":"bib0023","first-page":"901","type":"other","article-title":"The use of basis functions in modelling joint articular surfaces: application to the knee joint","volume":"33","author":"Dhaher","year":"2000"},{"key":"bib0024","first-page":"761","type":"other","article-title":"Quantitation of articular surface topography and cartilage thickness in knee joints using stereophotogrammetry","volume":"24","author":"Ateshian","year":"1991"},{"key":"bib0025","first-page":"677","type":"other","article-title":"A three-dimensional mathematical model of the knee-joint","volume":"13","author":"Wismans","year":"1980"},{"key":"bib0026","first-page":"1335","type":"other","article-title":"Influence of meniscectomy and meniscus replacement on the stress distribution in human knee joint","volume":"36","author":"Vaziri","year":"2008"},{"key":"bib0027","first-page":"33","type":"other","article-title":"Finite element analysis of the meniscus: the influence of geometry and material properties on its behaviour","volume":"10","author":"Meakin","year":"2003"},{"key":"bib0028","first-page":"845","type":"other","article-title":"Pathways of load-induced cartilage damage causing cartilage degeneration in the knee after meniscectomy","volume":"36","author":"Wilson","year":"2003"},{"key":"bib0029","first-page":"62","type":"other","article-title":"Patient-specific parameterised cam geometry in finite element models of femoroacetabular impingement of the hip","volume":"54","author":"Cooper","year":"2018"},{"key":"bib0030","first-page":"570","type":"other","article-title":"Geometric parameterisation of pelvic bone and cartilage in contact analysis of the natural hip: An initial study","author":"Hua","year":"2015"},{"key":"bib0031","first-page":"1351","type":"other","article-title":"Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip","volume":"43","author":"Anderson","year":"2010"},{"key":"bib0032","first-page":"1121","type":"other","article-title":"Biomechanics of the meniscus-meniscal ligament construct of the knee","volume":"16","author":"Masouros","year":"2008"},{"key":"bib0033","first-page":"1756","type":"other","article-title":"The long-term consequence of anterior cruciate ligament and meniscus injuries: osteoarthritis","volume":"35","author":"Lohmander","year":"2007"},{"key":"bib0034","first-page":"439","type":"other","article-title":"The effect of collagen fibril orientation on the biphasic mechanics of articular cartilage","volume":"65","author":"Meng","year":"2017"},{"key":"bib0035","first-page":"998","type":"other","article-title":"A viscoelastic poromechanical model of the knee joint in large compression","volume":"36","author":"Kazemi","year":"2014"},{"key":"bib0036","first-page":"1111","type":"other","article-title":"Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading","volume":"49","author":"Ven\u00e4l\u00e4inen","year":"2016"},{"key":"bib0037","first-page":"639","type":"other","article-title":"Subchondral cysts create increased intra-osseous stress in early knee OA: a finite element analysis using simulated lesions","volume":"48","author":"McErlain","year":"2011"},{"key":"bib0038","first-page":"61","type":"other","article-title":"Predicting the effects of knee focal articular surface injury with a patient-specific finite element model","volume":"17","author":"Papaioannou","year":"2010"},{"key":"bib0039","first-page":"3387","type":"other","article-title":"Spatial variation of fixed charge density in knee joint cartilage from sodium MRI\u2013implication on knee joint mechanics under static loading","volume":"49","author":"R\u00e4s\u00e4nen","year":"2016"},{"key":"bib0040","first-page":"405","type":"other","article-title":"Equivalence between short-time biphasic and incompressible elastic material responses","volume":"129","author":"Ateshian","year":"2007"},{"key":"bib0041","first-page":"579","type":"other","article-title":"Effect of superficial collagen patterns and fibrillation of femoral articular cartilage on knee joint mechanics\u2014a 3D finite element analysis","volume":"45","author":"Mononen","year":"2012"},{"key":"bib0042","first-page":"2934","type":"other","article-title":"An MRI-compatible loading device to assess knee joint cartilage deformation: effect of preloading and inter-test repeatability","volume":"48","author":"Wang","year":"2015"},{"key":"bib0043","first-page":"1397","type":"other","article-title":"A multi-scale finite element model for investigation of chondrocyte mechanics in normal and medial meniscectomy human knee joint during walking","volume":"48","author":"Tanska","year":"2015"},{"key":"bib0044","first-page":"2456","type":"other","article-title":"Multiscale mechanics of articular cartilage: potentials and challenges of coupling musculoskeletal, joint, and microscale computational models","volume":"40","author":"Halloran","year":"2012"},{"key":"bib0045","first-page":"3532","type":"other","article-title":"A multiscale framework based on the physiome markup languages for exploring the initiation of osteoarthritis at the bone\u2013cartilage interface","volume":"58","author":"Shim","year":"2011"},{"key":"bib0046","first-page":"363","type":"other","article-title":"Finite element modeling of soft tissues: material models, tissue interaction and challenges","volume":"29","author":"Freutel","year":"2014"},{"key":"bib0047","first-page":"2467","type":"other","article-title":"Deformation of articular cartilage during static loading of a knee joint\u2013experimental and finite element analysis","volume":"47","author":"Halonen","year":"2014"},{"key":"bib0048","first-page":"376","type":"other","article-title":"Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data","volume":"6","author":"Stentz-Olesen","year":"2017"},{"key":"bib0049","first-page":"146","type":"other","article-title":"A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement","volume":"77","author":"Shu","year":"2018"},{"key":"bib0050","first-page":"17396","type":"other","article-title":"Workflow assessing the effect of gait alterations on stresses in the medial tibial cartilage-combined musculoskeletal modelling and finite element analysis","volume":"7","author":"Halonen","year":"2017"},{"key":"bib0051","first-page":"54","type":"other","article-title":"Material models and properties in the finite element analysis of knee ligaments: a literature review","volume":"2","author":"Galbusera","year":"2014"},{"key":"bib0052","first-page":"3145","type":"other","article-title":"High prevalence of knee osteoarthritis, pain, and functional limitations in female soccer players twelve years after anterior cruciate ligament injury","volume":"50","author":"Lohmander","year":"2004"},{"key":"bib0053","first-page":"2566","type":"other","article-title":"Optimal graft stiffness and pre-strain restore normal joint motion and cartilage responses in ACL reconstructed knee","volume":"49","author":"Halonen","year":"2016"},{"key":"bib0054","first-page":"1353","type":"other","article-title":"Steeper posterior tibial slope markedly increases ACL force in both active gait and passive knee joint under compression","volume":"47","author":"Marouane","year":"2014"},{"key":"bib0055","first-page":"201","type":"other","article-title":"Biomechanics of changes in ACL and PCL material properties or prestrains in flexion under muscle force-implications in ligament reconstruction","volume":"9","author":"Mesfar","year":"2006"},{"key":"bib0056","first-page":"1189","type":"other","article-title":"The peripheral soft tissues should not be ignored in the finite element models of the human knee joint","volume":"56","author":"Beidokhti","year":"2018"},{"key":"bib0057","first-page":"673","type":"other","article-title":"Magnetic resonance image analysis of meniscal translation and tibio-menisco-femoral contact in deep knee flexion","volume":"26","author":"Yao","year":"2008"},{"key":"bib0058","first-page":"1343","type":"other","article-title":"Material properties of individual menisci and their attachments obtained through inverse FE-analysis","volume":"48","author":"Freutel","year":"2015"},{"key":"bib0059","first-page":"451","type":"other","article-title":"Extracting clinically relevant data from finite element simulations","volume":"20","author":"Viceconti","year":"2005"},{"key":"bib0060","first-page":"61","type":"other","article-title":"Osteochondral grafting: effect of graft alignment, material properties, and articular geometry","volume":"3","author":"D'Lima","year":"2009"},{"key":"bib0061","first-page":"2233","type":"other","article-title":"Reducing uncertainty when using knee-specific finite element models by assessing the effect of input parameters","volume":"35","author":"Guo","year":"2017"},{"key":"bib0062","first-page":"1444","type":"other","article-title":"A statistically-augmented computational platform for evaluating meniscal function","volume":"48","author":"Guo","year":"2015"},{"key":"bib0063","first-page":"1433","type":"other","article-title":"The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee","volume":"16","author":"Peterfy","year":"2008"},{"key":"bib0064","first-page":"24701","type":"other","article-title":"Perspectives on Sharing Models and Related Resources in Computational Biomechanics Research","volume":"140","author":"Erdemir","year":"2018"},{"key":"bib0065","article-title":"Deciphering the \u201cArt\u201d in modeling and simulation of the knee joint","author":"Erdemir","year":"2019","type":"other"},{"key":"bib0066","first-page":"107","type":"other","article-title":"Open knee: open source modeling and simulation in knee biomechanics","volume":"29","author":"Erdemir","year":"2016"},{"key":"bib0067","first-page":"1543","type":"other","article-title":"Automated hexahedral meshing of knee cartilage structures\u2013application to data from the osteoarthritis initiative","volume":"20","author":"Rodriguez-Vila","year":"2017"},{"key":"bib0068","first-page":"1427","type":"other","article-title":"The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant","volume":"48","author":"Khoshgoftar","year":"2015"},{"key":"bib0069","first-page":"1287","type":"other","article-title":"Finite element analysis of the spine: towards a framework of verification, validation and sensitivity analysis","volume":"30","author":"Jones","year":"2008"},{"key":"bib0070","first-page":"625","type":"other","article-title":"Considerations for reporting finite element analysis studies in biomechanics","volume":"45","author":"Erdemir","year":"2012"},{"key":"bib0071","first-page":"801","type":"other","article-title":"Validation of computational models in biomechanics","volume":"224","author":"Henninger","year":"2010"},{"key":"bib0072","first-page":"171","type":"other","article-title":"Verification, validation and sensitivity studies in computational biomechanics","volume":"10","author":"Anderson","year":"2007"},{"key":"bib0073","first-page":"21005","type":"other","article-title":"Applicability analysis of validation evidence for biomedical computational models","volume":"2","author":"Pathmanathan","year":"2017"},{"key":"bib0074","first-page":"11005","type":"other","article-title":"FEBio: finite elements for biomechanics","volume":"134","author":"Maas","year":"2012"},{"key":"bib0075","first-page":"2337","type":"other","article-title":"Comparison of hexahedral and tetrahedral elements in finite element analysis of the foot and footwear","volume":"44","author":"Tadepalli","year":"2011"},{"key":"bib0076","first-page":"659","type":"other","article-title":"Finite element simulation of articular contact mechanics with quadratic tetrahedral elements","volume":"49","author":"Maas","year":"2016"},{"key":"bib0077","first-page":"1275","type":"other","article-title":"Finite element simulations of a hip joint with femoroacetabular impingement","author":"Jorge","year":"2014"},{"key":"bib0078","type":"other","article-title":"Annulus fibrosus functional extrafibrillar and fibrous mechanical behaviour: experimental and computational characterisation","volume":"4","author":"Mengoni","year":"2017"},{"key":"bib0079","first-page":"302","type":"other","article-title":"Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee","volume":"49","author":"Ali","year":"2016"},{"key":"bib0080","first-page":"81004","type":"other","article-title":"A combined experimental and computational approach to subject-specific analysis of knee joint laxity","volume":"138","author":"Harris","year":"2016"},{"key":"bib0081","first-page":"11002","type":"other","article-title":"Finite element model of the knee for investigation of injury mechanisms: development and validation","volume":"136","author":"Kiapour","year":"2014"},{"key":"bib0082","first-page":"497","type":"other","article-title":"A human knee joint model considering fluid pressure and fiber orientation in cartilages and menisci","volume":"33","author":"Gu","year":"2011"},{"key":"bib0083","first-page":"3349","type":"other","article-title":"Cartilage evaluation with biochemical MR imaging using in vivo Knee compression at 3 T-comparison of patients after cartilage repair with healthy volunteers","volume":"48","author":"Schoenbauer","year":"2015"},{"key":"bib0084","first-page":"19","type":"other","article-title":"How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint","volume":"36","author":"Donahue","year":"2003"},{"key":"bib0085","first-page":"115","type":"other","article-title":"3D finite element model of meniscectomy: changes in joint contact behavior","volume":"128","author":"Zielinska","year":"2006"},{"key":"bib0086","first-page":"2569","type":"other","article-title":"Accuracy of circular contact area measurements with thin-film pressure sensors","volume":"40","author":"Drewniak","year":"2007"},{"key":"bib0087","first-page":"69","type":"other","article-title":"Biomechanics of the human knee joint in compression: reconstruction, mesh generation and finite element analysis","volume":"2","author":"Bendjaballah","year":"1995"},{"key":"bib0088","first-page":"382","type":"other","article-title":"A patient-specific wear prediction framework for an artificial knee joint with coupled musculoskeletal multibody-dynamics and finite element analysis","volume":"109","author":"Zhang","year":"2017"},{"key":"bib0089","first-page":"21001","type":"other","article-title":"Partial meniscectomy changes fluid pressurization in articular cartilage in human knees","volume":"134","author":"Kazemi","year":"2012"},{"key":"bib0090","first-page":"182","type":"other","article-title":"Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage","volume":"30","author":"Li","year":"2008"},{"key":"bib0091","first-page":"279","type":"other","article-title":"Load-bearing in the knee joint","volume":"Mar\u2013Apr;131","author":"Shrive","year":"1978"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453319301572?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453319301572?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2019.08.002","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2019.08.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2019.08.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2019.08.002\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:55:23Z","timestamp":1769093723000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2019.08.002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,3]]},"references-count":91,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,9,3]]},"published-print":{"date-parts":[[2019,12,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2019.08.002","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,3]]},"assertion":[{"value":"Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2018-10-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-08-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-09-03","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}