{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T02:26:28Z","timestamp":1790303188093,"version":"4.1.0"},"reference-count":23,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T00:00:00Z","timestamp":1597363200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T00:00:00Z","timestamp":1597363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000272","name":"National Institute for Health Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000272","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100010055","name":"University of Salford Manchester","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100010055","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2020,10,1]]},"DOI":"10.1016\/j.medengphy.2020.08.003","type":"journal-article","created":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T21:54:22Z","timestamp":1597355662000},"page":"136-143","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design"],"prefix":"10.1088","volume":"84","author":[{"given":"Michael","family":"Prince","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurence PJ","family":"Kenney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dave","family":"Howard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2020,8,14]]},"reference":[{"key":"bib0001","author":"","year":"2017","type":"other"},{"key":"bib0002","author":"","year":"2004","type":"other"},{"key":"bib0003","first-page":"483","type":"other","article-title":"Expert opinions on success factors for upper-limb prostheses","volume":"44","author":"Schultz","year":"2007"},{"key":"bib0004","first-page":"977","type":"other","article-title":"Upper-limb prosthetics: Critical factors in device abandonment","volume":"86","author":"Biddiss","year":"2007"},{"key":"bib0005","type":"other"},{"key":"bib0006","type":"other"},{"key":"bib0007","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1682\/JRRD.2013.06.0133","type":"other","article-title":"Prevalence of heat and perspiration discomfort inside prostheses: Literature review","volume":"51","author":"Ghoseiri","year":"2014"},{"key":"bib0008","type":"other"},{"key":"bib0009","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.medengphy.2017.02.008","type":"other","article-title":"Finite element analysis of the amputated lower limb: A systematic review and recommendations","volume":"43","author":"Dickinson","year":"2017"},{"key":"bib0010","first-page":"2583","type":"other","article-title":"Surgical and morphological factors that affect internal mechanical loads in soft tissues of the transtibial residuum","volume":"37","author":"Gefen","year":"2009"},{"key":"bib0011","first-page":"2222","type":"other","article-title":"A new pressure ulcer conceptual framework","volume":"70","author":"Coleman","year":"2014"},{"key":"bib0012","first-page":"99","type":"other","article-title":"Socket pressure and discomfort in upper-limb prostheses: A preliminary study","volume":"26","author":"Daly","year":"2014"},{"key":"bib0013","first-page":"1","type":"other","article-title":"Characterization of interfacial socket pressure in transhumeral prostheses: A case series","volume":"12","author":"Schofield","year":"2017"},{"key":"bib0014","first-page":"38","type":"other","article-title":"Transferring Load to Flesh. Part 1: Concepts","volume":"10","author":"Murphy","year":"1971"},{"key":"bib0015","first-page":"55","type":"other","article-title":"Dynamic indentation on human skin in vivo: Ageing effects","volume":"15","author":"Boyer","year":"2009"},{"key":"bib0016","first-page":"1245","type":"other","article-title":"Experimental and computational analysis of soft tissue stiffness in forearm using a manual indentation device","volume":"33","author":"Iivarinen","year":"2011"},{"key":"bib0017","first-page":"71","type":"other","article-title":"Objective assessment of limb tissue elasticity: Development of a manual indentation procedure","volume":"36","author":"Zheng","year":"1999"},{"key":"bib0018","type":"other","article-title":"Regional variations of in vivo surface stiffness of soft tissue layers of musculoskeletal extremities","volume":"95","author":"Neumann","year":"2019"},{"key":"bib0019","first-page":"650","type":"other","article-title":"Characteristics of a volume-adjustable compression chamber for transradial prosthetic interface","volume":"230","author":"Sang","year":"2016"},{"key":"bib0020","first-page":"49","type":"other","article-title":"Influence of indentation test factors on the mechanical response of the skin","volume":"24","author":"Isaza","year":"2019"},{"key":"bib0021","first-page":"71","type":"other","article-title":"Hertzian load-displacement relation holds for spherical indentation on soft elastic solids undergoing large deformations","volume":"97","author":"Wu","year":"2016"},{"key":"bib0022","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-662-58709-6_2.","type":"other"},{"key":"bib0023","first-page":"268","type":"other","article-title":"In vivo indentation of lower extremity limb soft tissues","volume":"7","author":"Silver-Thorn","year":"1999"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453320301272?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453320301272?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2020.08.003","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2020.08.003\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2020.08.003\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2020.08.003\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:57:29Z","timestamp":1769093849000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2020.08.003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,14]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,8,14]]},"published-print":{"date-parts":[[2020,10,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2020.08.003","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,14]]},"assertion":[{"value":"A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2020 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-02-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-08-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-08-14","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}