{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T00:10:34Z","timestamp":1794269434933,"version":"4.9.0"},"reference-count":69,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2021,12,12]],"date-time":"2021-12-12T00:00:00Z","timestamp":1639267200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,12,12]],"date-time":"2021-12-12T00:00:00Z","timestamp":1639267200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2022,1,1]]},"DOI":"10.1016\/j.medengphy.2021.103742","type":"journal-article","created":{"date-parts":[[2021,12,12]],"date-time":"2021-12-12T13:39:57Z","timestamp":1639316397000},"page":"103742","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":45,"title":["Structural testing of lower-limb prosthetic sockets: A systematic review"],"prefix":"10.1088","volume":"99","author":[{"given":"Francesca","family":"Gariboldi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele","family":"Pasquarelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea Giovanni","family":"Cutti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,12,12]]},"reference":[{"key":"bib0001","first-page":"67","type":"other","article-title":"Relative strength of pylon-to-socket attachment systems used in transtibial composite sockets","volume":"19","author":"Graebner","year":"2007"},{"key":"bib0002","first-page":"295","type":"other","article-title":"Strength testing of definitive transtibial prosthetic sockets made using 3D-printing technology","volume":"32","author":"Nickel","year":"2020"},{"key":"bib0003","article-title":"European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001\/83\/EC","author":"","year":"2017","type":"other"},{"key":"bib0004","type":"other","article-title":"BSI Standards Publication Prosthetics \u2014 Structural testing of lower-limb prostheses \u2014 Requirements and test methods (ISO 10328\u00a0: 2016)","volume":"10328","author":"","year":"2016"},{"key":"bib0005","type":"other","article-title":"PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews","volume":"372","author":"Page","year":"2021"},{"key":"bib0006","type":"other","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021"},{"key":"bib0007","first-page":"178","type":"other","article-title":"Highlights of other VA research programs","volume":"10","author":"Murphy","year":"1976"},{"key":"bib0008","first-page":"5382","type":"other","article-title":"Evaluation of the influence of cyclic loading on a laser sintered transtibial prosthetic socket using Digital Image Correlation (DIC)","volume":"2019","author":"Saey","year":"2019"},{"key":"bib0009","first-page":"383","type":"other","article-title":"Mechanical and fatigue behaviors of prosthetic for partial foot amputation with various composite materials types effect","volume":"9","author":"Abbas","year":"2018"},{"key":"bib0010","first-page":"560","type":"other","article-title":"Manufacturing and analysis of ankle disarticulation prosthetic socket (SYMES)","volume":"9","author":"Abbas","year":"2018"},{"key":"bib0011","first-page":"1","type":"other","article-title":"Fatigue characteristics and numerical modelling prosthetic for chopart amputation","volume":"2020","author":"Abbas","year":"2020"},{"key":"bib0012","first-page":"62","type":"other","article-title":"Manufacturing and analysis of partial foot prosthetic for the Pirogoff amputation","volume":"18","author":"Takhakh","year":"2018"},{"key":"bib0013","first-page":"470","type":"other","article-title":"Method for the design and analysis of a non-linear anisotropic lower limb prosthetic socket","volume":"12","author":"Soh","year":"1990"},{"key":"bib0014","first-page":"775","type":"other","article-title":"Finite-element analysis to determine effect of monolimb flexibility on structural strength and interaction between residual limb and prosthetic socket","volume":"41","author":"Lee","year":"2004"},{"key":"bib0015","first-page":"290","type":"other","article-title":"A numerical approach to evaluate the fatigue life of monolimb","volume":"28","author":"Chen","year":"2006"},{"key":"bib0016","first-page":"363","type":"other","article-title":"Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee","volume":"38","author":"Kumar","year":"2014"},{"key":"bib0017","first-page":"108","type":"other","article-title":"Dynamic stresses and deformations investigation of the below knee prosthesis using CT-scan modeling","volume":"19","author":"Jweeg","year":"2019"},{"key":"bib0018","first-page":"641","type":"other","article-title":"Effects of ultraviolet radiation with and without heat on the fatigue behavior of below-knee prosthetic sockets","volume":"7","author":"Hussien","year":"2017"},{"key":"bib0019","first-page":"88","type":"other","article-title":"Advanced trans-tibial socket fabrication using selective laser sintering","volume":"31","author":"Rogers","year":"2007"},{"key":"bib0020","first-page":"815","type":"other","article-title":"Stance phase mechanical characterization of transtibial prostheses distal to the socket: a review","volume":"49","author":"Major","year":"2012"},{"key":"bib0021","first-page":"1","type":"other","article-title":"Experimental and numerical analysis of below knee prosthetic socket","volume":"9","author":"Jebur","year":"2018"},{"key":"bib0022","type":"other","article-title":"Using mechanical testing to assess texturing of prosthetic sockets to improve suspension in the transverse plane and reduce rotation","volume":"15","author":"Quinlan","year":"2020"},{"key":"bib0023","first-page":"27","type":"other","article-title":"Material Properties of Selected Prosthetic Laminates","volume":"17","author":"Phillips","year":"2005"},{"key":"bib0024","first-page":"987","type":"other","article-title":"Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets","volume":"48","author":"Gerschutz","year":"2011"},{"key":"bib0025","first-page":"46","type":"other","article-title":"Tensile and flexural strength of ramie fiber reinforced epoxy composites for socket prosthesis application","volume":"6","author":"Irawan","year":"2011"},{"key":"bib0026","first-page":"118","type":"other","article-title":"Mechanical properties of polymer with different reinforcement material composite that used for fabricates prosthetic socket","volume":"42","author":"Kadhim","year":"2019"},{"key":"bib0027","first-page":"384","type":"other","article-title":"Fatigue characterization of laminated composites used in prosthetic sockets manufacturing","volume":"43","author":"Abbas","year":"2020"},{"key":"bib0028","first-page":"379","type":"other","article-title":"Improving the composite materials for bi lateral prosthesis with below knee amputation","volume":"1002","author":"Abbas","year":"2020"},{"key":"bib0029","first-page":"405","type":"other","article-title":"Investigation of Agave cantala-based composite fibers as prosthetic socket materials accounting for a variety of alkali and microcrystalline cellulose treatments","volume":"10","author":"Sakuri","year":"2020"},{"key":"bib0030","article-title":"3D-printed polypropylene transtibial sockets: mechanical behavior","author":"Stewart","year":"2020","type":"other"},{"key":"bib0031","type":"other","article-title":"Preliminary material evaluation of flax fibers for prosthetic socket fabrication","volume":"143","author":"Monette","year":"2021"},{"key":"bib0032","first-page":"117","type":"other","article-title":"Dynamic testing of below-knee prosthesis: assembly and components","volume":"11","author":"Wevers","year":"1987"},{"key":"bib0033","first-page":"113","type":"other","article-title":"Static structural testing of trans-tibial composite sockets","volume":"23","author":"Current","year":"1999"},{"key":"bib0034","first-page":"241","type":"other","article-title":"Technical note: principal structural testing of transtibial prosthetic assemblies: specimen preparation","volume":"24","author":"Neo","year":"2000"},{"key":"bib0035","first-page":"359","type":"other","article-title":"Structural integrity of polypropylene prosthetic sockets manufactured using the polymer deposition technique","volume":"216","author":"Goh","year":"2002"},{"key":"bib0036","first-page":"759","type":"other","article-title":"Design of monolimb using finite element modelling and statistics-based Taguchi method","volume":"20","author":"Lee","year":"2005"},{"key":"bib0037","first-page":"304","type":"other","article-title":"An experimental and theoretical framework for manufacturing prosthetic sockets for transtibial amputees","volume":"14","author":"Faustini","year":"2006"},{"key":"bib0038","first-page":"181","type":"other","article-title":"Prosthetic limb sockets from plant-based composite materials","volume":"36","author":"Campbell","year":"2012"},{"key":"bib0039","first-page":"405","type":"other","article-title":"Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets","volume":"49","author":"Gerschutz","year":"2012"},{"key":"bib0040","type":"other","article-title":"An investigation of the structural strength of transtibial sockets fabricated using conventional methods and rapid prototyping techniques","volume":"2","author":"Pousett","year":"2019"},{"key":"bib0041","first-page":"103","type":"other","article-title":"Additive manufacturing of prostheses using forest-based composites","volume":"7","author":"Stenvall","year":"2020"},{"key":"bib0042","first-page":"19","type":"other","article-title":"Development and testing of thermoplastic structural components for modular prostheses","volume":"12","author":"Coombes","year":"1988"},{"key":"bib0043","first-page":"6","type":"other","article-title":"Finite element structural analysis of prosthesis sockets for below-the-knee amputees manufactured using SLS","author":"Faustini","year":"2001"},{"key":"bib0044","type":"other"},{"key":"bib0045","first-page":"114","type":"other","article-title":"The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods","volume":"28","author":"Faustini","year":"Mar. 2006"},{"key":"bib0046","first-page":"7","author":"Oleiwi","year":"2015","type":"other"},{"key":"bib0047","type":"other","article-title":"How infill percentage affects the ultimate strength of 3d-printed transtibial sockets during initial contact","volume":"1","author":"Campbell","year":"2018"},{"key":"bib0048","doi-asserted-by":"publisher","DOI":"10.1088\/1757-899X\/433\/1\/012058.","type":"other"},{"key":"bib0049","first-page":"577","type":"other","article-title":"Mechanical performance of polymer powder bed fused objects \u2013 FEM simulation and verification","volume":"24","author":"Lindberg","year":"2018"},{"key":"bib0050","type":"other"},{"key":"bib0051","first-page":"124","type":"other","article-title":"3D-printed BK and AK prosthetic socket testing system","author":"Golovin","year":"2020"},{"key":"bib0052","first-page":"93","type":"other","article-title":"Transtibial prosthetic socket strength: the use of ISO 10328 in the comparison of standard and 3D-printed sockets","volume":"32","author":"Owen","year":"2020"},{"key":"bib0053","first-page":"84","type":"other","article-title":"ISO BS EN 22523:2006 External limb prostheses and external orthoses. Requirements and test methods","author":"","year":"2006"},{"key":"bib0054","first-page":"479","type":"other","article-title":"Kinematics of normal locomotion-a statistical study based on T.V. data","volume":"7","author":"Winter","year":"1974"},{"key":"bib0055","first-page":"40","type":"other","article-title":"BSI standards publication prosthetics \u2014 testing of ankle- foot devices and foot units \u2014 requirements and test methods (ISO 22675\u00a0: 2016)","author":"","year":"2016"},{"key":"bib0056","first-page":"2","type":"other","article-title":"Alignment of lower-limb prostheses","volume":"23","author":"Zahedi","year":"1986"},{"key":"bib0057","first-page":"114","type":"other","article-title":"The effect of prosthesis alignment on the symmetry of gait in subjects with unilateral transtibial amputation","volume":"30","author":"Chow","year":"2006"},{"key":"bib0058","first-page":"655","type":"other","article-title":"Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket","volume":"26","author":"Lee","year":"2004"},{"key":"bib0059","first-page":"21","type":"other","article-title":"Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies","volume":"23","author":"Sanders","year":"1999"},{"key":"bib0060","first-page":"188","type":"other","article-title":"Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis","volume":"20","author":"Zhang","year":"1998"},{"key":"bib0061","article-title":"Modeling and fabrication of prosthetic sockets using selective laser sintering","author":"Faustini","year":"2004","type":"other"},{"key":"bib0062","first-page":"13","type":"other","article-title":"Das Kniegelenk des Menschen als biomechanisches Problem - The human knee-joint as a biomechanical problem","volume":"22","author":"Nietert","year":"1977"},{"key":"bib0063","type":"other"},{"key":"bib0064","type":"other","article-title":"Using mechanical testing to assess the effect of lower-limb prosthetic socket texturing on longitudinal suspension","volume":"15","author":"Quinlan","year":"2020"},{"key":"bib0065","first-page":"235","type":"other","article-title":"Development of a residuum\/socket interface simulator for lower limb prosthetics","volume":"231","author":"McGrath","year":"2017"},{"key":"bib0066","type":"other","article-title":"Developing an analogue residual limb for comparative DVC analysis of transtibial prosthetic socket designs","volume":"13","author":"Rankin","year":"2020"},{"key":"bib0067","first-page":"1","type":"other","article-title":"Finite element analysis of the amputated lower limb: a systematic review and recommendations","volume":"43","author":"Dickinson","year":"2017"},{"key":"bib0068","first-page":"1331","type":"other","article-title":"Predictive prosthetic socket design: part 1\u2014Population-based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling","volume":"19","author":"Steer","year":"2020"},{"key":"bib0069","first-page":"1347","type":"other","article-title":"Predictive prosthetic socket design: part 2\u2014Generating person-specific candidate designs using multi-objective genetic algorithms","volume":"19","author":"Steer","year":"2020"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453321001429?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453321001429?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103742","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103742\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103742\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103742\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:54:13Z","timestamp":1769093653000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103742"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,12]]},"references-count":69,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12,12]]},"published-print":{"date-parts":[[2022,1,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2021.103742","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,12]]},"assertion":[{"value":"Structural testing of lower-limb prosthetic sockets: A systematic review","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-06-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-12-10","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-12-12","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}