{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T12:24:34Z","timestamp":1782908674145,"version":"3.54.5"},"reference-count":61,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2021,12,23]],"date-time":"2021-12-23T00:00:00Z","timestamp":1640217600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,12,23]],"date-time":"2021-12-23T00:00:00Z","timestamp":1640217600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["1344954"],"award-info":[{"award-number":["1344954"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["1536035"],"award-info":[{"award-number":["1536035"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2022,2,1]]},"DOI":"10.1016\/j.medengphy.2021.103744","type":"journal-article","created":{"date-parts":[[2021,12,23]],"date-time":"2021-12-23T02:09:54Z","timestamp":1640225394000},"page":"103744","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration"],"prefix":"10.1088","volume":"100","author":[{"given":"Holly","family":"Warner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Poya","family":"Khalaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanz","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Simon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Hardin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonie J.","family":"van den Bogert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,12,23]]},"reference":[{"key":"bib0001","first-page":"422","type":"other","article-title":"Estimating the prevalence of limb loss in the United States: 2005 to 2050","volume":"89","author":"Ziegler-Graham","year":"2008"},{"key":"bib0002","first-page":"147","type":"other","article-title":"Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences","volume":"175","author":"Winter","year":"1983"},{"key":"bib0003","first-page":"440","type":"other","article-title":"The prevalence of osteoarthritis of the intact hip and knee among traumatic leg amputees","volume":"90","author":"Struyf","year":"2009"},{"key":"bib0004","first-page":"15","type":"other","article-title":"Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use","volume":"45","author":"Gailey","year":"2008"},{"key":"bib0005","first-page":"42","type":"other","article-title":"Energy cost of walking of amputees: the influence of level of amputation","volume":"58","author":"Waters","year":"1976"},{"key":"bib0006","first-page":"394","type":"other","article-title":"A biomechatronical transtibial prosthesis powered by pleated pneumatic artificial muscles","volume":"4","author":"Versluys","year":"2008"},{"key":"bib0007","first-page":"263","type":"other","article-title":"Design and control of a powered transfemoral prosthesis","volume":"27","author":"Sup","year":"2008"},{"key":"bib0008","first-page":"18","author":"Wilmot","year":"2013","type":"other"},{"key":"bib0009","first-page":"52","type":"other","article-title":"Powered ankle-foot prosthesis","volume":"15","author":"Au","year":"2008"},{"key":"bib0010","first-page":"361","type":"other","article-title":"Agonist-antagonist active knee prosthesis: a preliminary study in level-ground walking","volume":"46","author":"Martinez-Villalpando","year":"2009"},{"key":"bib0011","first-page":"011003","type":"other","article-title":"An active foot-ankle prosthesis with biomechanical energy regeneration","volume":"4","author":"Hitt","year":"2010"},{"key":"bib0012","first-page":"138","type":"other","article-title":"Design and validation of the ankle mimicking prosthetic (AMP-) foot 2.0","volume":"22","author":"Cherelle","year":"2014"},{"key":"bib0013","first-page":"70","type":"other","article-title":"A robotic leg prosthesis: design, control, and implementation","volume":"21","author":"Lawson","year":"2014"},{"key":"bib0014","type":"other","article-title":"Physical performance and self-report outcomes associated with use of passive, adaptive, and active prosthetic knees in persons with unilateral, transfemoral amputation: randomized crossover trial","volume":"52","author":"Hafner","year":"2015"},{"key":"bib0015","first-page":"667","type":"other","article-title":"Preliminary evaluations of a self-contained anthropomorphic transfemoral prosthesis","volume":"14","author":"Sup","year":"2009"},{"key":"bib0016","first-page":"71","type":"other","article-title":"Upslope walking with a powered knee and ankle prosthesis: initial results with an amputee subject","volume":"19","author":"Sup","year":"2011"},{"key":"bib0017","first-page":"1725","type":"other","article-title":"Generating electricity while walking with loads","volume":"309","author":"Rome","year":"2005"},{"key":"bib0018","first-page":"821","type":"other","article-title":"A review of human-powered energy harvesting for smart electronics: recent progress and challenges","volume":"6","author":"Khalid","year":"2019"},{"key":"bib0019","first-page":"065027","type":"other","article-title":"A knee-mounted biomechanical energy harvester with enhanced efficiency and safety","volume":"26","author":"Chen","year":"2017"},{"key":"bib0020","first-page":"149","type":"other","article-title":"Energy-efficient braking torque control of robotic transtibial prosthesis","volume":"22","author":"Yuan","year":"2017"},{"key":"bib0021","first-page":"1442","type":"other","article-title":"Energy regeneration from electromagnetic induction by human dynamics for lower extremity robotic prostheses","volume":"36","author":"Feng","year":"2020"},{"key":"bib0022","first-page":"4108","author":"Rarick","year":"2014","type":"other"},{"key":"bib0023","author":"Warner","year":"2015","type":"other"},{"key":"bib0024","first-page":"894","type":"other","article-title":"Optimal mixed tracking\/impedance control with application to transfemoral prostheses with energy regeneration","volume":"65","author":"Khademi","year":"2017"},{"key":"bib0025","first-page":"e0188266","type":"other","article-title":"Optimal design and control of an electromechanical transfemoral prosthesis with energy regeneration","volume":"12","author":"Rohani","year":"2017"},{"key":"bib0026","first-page":"1611","type":"other","article-title":"Clutchable series-elastic actuator: implications for prosthetic knee design","volume":"33","author":"Rouse","year":"2014"},{"key":"bib0027","first-page":"035034","type":"other","article-title":"Optimal design of a magnetorheological damper used in smart prosthetic knees","volume":"26","author":"Gao","year":"2017"},{"key":"bib0028","author":"Hunter","year":"1981","type":"other"},{"key":"bib0029","author":"Seth","year":"1987","type":"other"},{"key":"bib0030","author":"Tabor","year":"1988","type":"other"},{"key":"bib0031","first-page":"390","type":"other","article-title":"Evaluation of a prosthetic swing-phase controller with electrical power generation","volume":"17","author":"Andrysek","year":"2009"},{"key":"bib0032","first-page":"13","author":"Tucker","year":"2010","type":"other"},{"key":"bib0033","first-page":"040801","type":"other","article-title":"Lower-limb prostheses and exoskeletons with energy regeneration: mechatronic design and optimization review","volume":"11","author":"Laschowski","year":"2019"},{"key":"bib0034","first-page":"51","type":"other","article-title":"Powered ankle-foot prosthesis improves walking metabolic economy","volume":"25","author":"Au","year":"2009"},{"key":"bib0035","first-page":"441","type":"other","article-title":"Robotic transtibial prosthesis with biomechanical energy regeneration","volume":"36","author":"Hitt","year":"2009"},{"key":"bib0036","first-page":"e0147661","type":"other","article-title":"Assessing the relative contributions of active ankle and knee assistance to the walking mechanics of transfemoral amputees using a powered prosthesis","volume":"11","author":"Ingraham","year":"2016"},{"key":"bib0037","first-page":"523","author":"Sup","year":"2008","type":"other"},{"key":"bib0038","first-page":"466","type":"other","article-title":"Control of stair ascent and descent with a powered transfemoral prosthesis","volume":"21","author":"Lawson","year":"2013"},{"key":"bib0039","first-page":"2187","author":"Warner","year":"2016","type":"other"},{"key":"bib0040","first-page":"85","author":"Fey","year":"2013","type":"other"},{"key":"bib0041","first-page":"e99387","type":"other","article-title":"Configuring a powered knee and ankle prosthesis for transfemoral amputees within five specific ambulation modes","volume":"9","author":"Simon","year":"2014"},{"key":"bib0042","first-page":"1","type":"other","article-title":"Control strategies for active lower extremity prosthetics and orthotics: a review","volume":"12","author":"Tucker","year":"2015"},{"key":"bib0043","first-page":"091004","type":"other","article-title":"A framework for control of robots with energy regeneration","volume":"137","author":"Richter","year":"2015"},{"key":"bib0044","first-page":"031003","type":"other","article-title":"On global, closed-form solutions to parametric optimization problems for robots with energy regeneration","volume":"140","author":"Khalaf","year":"2018"},{"key":"bib0045","first-page":"1424","author":"Khalaf","year":"2016","type":"other"},{"key":"bib0046","first-page":"501","type":"other","article-title":"Trajectory optimization of robots with regenerative drive systems: numerical and experimental results","volume":"36","author":"Khalaf","year":"2020"},{"key":"bib0047","author":"Conway","year":"2013","type":"other"},{"key":"bib0048","author":"Khalaf","year":"2018","type":"other"},{"key":"bib0049","first-page":"10244","author":"Richter","year":"2014","type":"other"},{"key":"bib0050","first-page":"1069","type":"other","article-title":"A real-time system for biomechanical analysis of human movement and muscle function","volume":"51","author":"van den Bogert","year":"2013"},{"key":"bib0051","author":"Winter","year":"2009","type":"other"},{"key":"bib0052","first-page":"857","type":"other","article-title":"Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg\u00ae and mauch SNS\u00ae prosthetic knees","volume":"43","author":"Segal","year":"2006"},{"key":"bib0053","first-page":"282","type":"other","article-title":"Influence of walking speed on gait parameters","volume":"7","author":"Kirtley","year":"1985"},{"key":"bib0054","first-page":"403","type":"other","article-title":"Running with a powered knee and ankle prosthesis","volume":"23","author":"Shultz","year":"2015"},{"key":"bib0055","first-page":"563","type":"other","article-title":"A clinical comparison of variable-damping and mechanically passive prosthetic knee devices","volume":"84","author":"Johansson","year":"2005"},{"key":"bib0056","first-page":"126","type":"other","article-title":"Lower extremity kinematic and kinetic adaptations in unilateral below-knee amputees during walking","volume":"6","author":"Sanderson","year":"1997"},{"key":"bib0057","first-page":"51","type":"other","article-title":"Kinematic and kinetic patterns in human gait: variability and compensating effects","volume":"3","author":"Winter","year":"1984"},{"key":"bib0058","first-page":"219","type":"other","article-title":"Normative data of knee joint motion and ground reaction forces in adult level walking","volume":"16","author":"Chao","year":"1983"},{"key":"bib0059","first-page":"11","type":"other","article-title":"Determination and interpretation of mechanical power in human movement: application to ergometer cycling","volume":"61","author":"van Ingen Schenau","year":"1990"},{"key":"bib0060","first-page":"4257","type":"other","article-title":"Human walking isn\u2019t all hard work: evidence of soft tissue contributions to energy dissipation and return","volume":"213","author":"Zelik","year":"2010"},{"key":"bib0061","first-page":"167","type":"other","article-title":"Heuristic versus optimal charging of supercapacitors, lithium-ion, and lead-acid batteries: an efficiency point of view","volume":"26","author":"Parvini","year":"2018"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453321001442?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453321001442?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103744","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103744\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103744\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103744\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:54:24Z","timestamp":1769093664000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2021.103744"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,23]]},"references-count":61,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12,23]]},"published-print":{"date-parts":[[2022,2,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2021.103744","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,23]]},"assertion":[{"value":"Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-01-27","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-12-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-12-23","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}