{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T06:27:37Z","timestamp":1769149657599,"version":"3.49.0"},"reference-count":47,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2022,2,11]],"date-time":"2022-02-11T00:00:00Z","timestamp":1644537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,2,11]],"date-time":"2022-02-11T00:00:00Z","timestamp":1644537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100007479","name":"Fondazione Cariparo","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007479","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2022,3,1]]},"DOI":"10.1016\/j.medengphy.2022.103773","type":"journal-article","created":{"date-parts":[[2022,2,11]],"date-time":"2022-02-11T11:43:35Z","timestamp":1644579815000},"page":"103773","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Beating heart implantation of transventricular artificial cordae: How can access site selection and leaflet insertion improve mitral regurgitation correction?"],"prefix":"10.1088","volume":"101","author":[{"given":"Luigi","family":"Di Micco","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benedetta","family":"Biffi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Silvia","family":"Schievano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela P.","family":"Boso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Besola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4029-5678","authenticated-orcid":true,"given":"Alessandro","family":"Fiocco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gino","family":"Gerosa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1082-5543","authenticated-orcid":true,"given":"Francesca M.","family":"Susin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2724-3961","authenticated-orcid":true,"given":"Andrea","family":"Colli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Peruzzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2022,2,11]]},"reference":[{"key":"bib0001","first-page":"191","type":"other","article-title":"Transesophageal echocardiography in NeoChord procedure","volume":"18","author":"Demetrio","year":"2015"},{"key":"bib0002","first-page":"575","type":"other","article-title":"Acute safety and efficacy of the NeoChord procedure","volume":"20","author":"Colli","year":"2015"},{"key":"bib0003","first-page":"322","type":"other","article-title":"TEE-guided transapical beating-heart neochord implantation in mitral regurgitation","volume":"7","author":"Colli","year":"2014"},{"key":"bib0004","first-page":"23","type":"other","article-title":"Transapical off-pump mitral valve repair with Neochord implantation: early clinical results","volume":"204","author":"Colli","year":"2016"},{"key":"bib0005","first-page":"871","type":"other","article-title":"Transoesophageal echo-guided mitral valve repair using the Harpoon system","volume":"53","author":"Gerosa","year":"2018"},{"key":"bib0006","first-page":"295","type":"other","article-title":"Transapical off-pump mitral valve repair with Neochord Implantation (TOP-MINI): step-by-step guide","volume":"4","author":"Colli","year":"2015"},{"key":"bib0007","first-page":"812","type":"other","article-title":"Transapical NeoChord mitral valve repair","volume":"7","author":"Colli","year":"2018"},{"key":"bib0008","first-page":"991","type":"other","article-title":"Beating heart mitral valve repair with neochordae implantation: real-time monitoring of haemodynamic recovery","volume":"52","author":"Colli","year":"2017"},{"key":"bib0009","first-page":"843","type":"other","article-title":"One-year outcomes after transapical echocardiography-guided mitral valve repair","volume":"138","author":"Colli","year":"2018"},{"key":"bib0010","first-page":"e199","type":"other","article-title":"Patient-specific ventricular access site selection for the NeoChord mitral valve repair procedure","volume":"104","author":"Colli","year":"2017"},{"key":"bib0011","first-page":"189","type":"other","article-title":"Transapical beating-heart mitral valve repair with an expanded polytetrafluoroethylene cordal implantation device","volume":"134","author":"Gammie","year":"2016"},{"key":"bib0012","first-page":"1","type":"other","article-title":"Transoesophageal echo-guided mitral valve repair using the Harpoon system","volume":"00","author":"Gerosa","year":"2017"},{"key":"bib0013","type":"other","article-title":"Finite element analysis of annuloplasty and papillary muscle relocation on a patient-specific mitral regurgitation model","volume":"13","author":"Kong","year":"2018"},{"key":"bib0014","first-page":"139","type":"other","article-title":"Mitral valve repair using ePTFE sutures for ruptured mitral chordae tendineae\u00a0: a computational simulation study","volume":"42","author":"Rim","year":"2014"},{"key":"bib0015","first-page":"98","type":"other","article-title":"Computational modelling for congenital heart disease: how far are we from clinical translation?","volume":"103","author":"Biglino","year":"2017"},{"key":"bib0016","first-page":"1303","type":"other","article-title":"Biomechanical drawbacks of different techniques of mitral neochordal implantation: when an apparently optimal repair can fail","volume":"150","author":"Sturla","year":"2015"},{"key":"bib0017","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.27633.Percutaneous.","type":"other"},{"key":"bib0018","first-page":"136","type":"other","article-title":"Replacement of mitral valve posterior chordae tendineae with expanded polytetrafluoroethylene suture: a finite element study","volume":"11","author":"Kunzelman","year":"1996"},{"key":"bib0019","first-page":"M754","type":"other","article-title":"The effect of anterior chordal replacement on mitral valve function and stresses: a finite element study","volume":"41","author":"Reimink","year":"1995"},{"key":"bib0020","type":"other","article-title":"Numerical simulation of transapical off-pump mitral valve repair with neochordae implantation","volume":"26","author":"Gaidulis","year":"2018"},{"key":"bib0021","type":"other","article-title":"A computational procedure for prediction of structural effects of edge-to-edge repair on mitral valve","volume":"130","author":"Avanzini","year":"2008"},{"key":"bib0022","first-page":"959","type":"other","article-title":"Functional and structural effects of percutaneous edge-to-edge double-orifice repair under cardiac cycle in comparison with suture repair","volume":"225","author":"Avanzini","year":"2011"},{"key":"bib0023","first-page":"117","type":"other","article-title":"Functional and biomechanical effects of the edge-to-edge repair in the setting of mitral regurgitation: consolidated knowledge and novel tools to gain insight into its percutaneous implementation","volume":"6","author":"Sturla","year":"2015"},{"key":"bib0024","first-page":"144","type":"other","article-title":"Adult : mitral valve : cardiothoracic imaging edge-to-edge mitral valve repair with transapical neochord implantation","volume":"156","author":"Colli","year":"2018"},{"key":"bib0025","first-page":"1","type":"other","article-title":"Computational virtual evaluation of the effect of annuloplasty ring shape","volume":"02831","author":"Choi","year":"2016"},{"key":"bib0026","first-page":"1104","type":"other","article-title":"The effect of patient-specific annular motion on dynamic simulation of mitral valve function","volume":"46","author":"Rim","year":"2013"},{"key":"bib0027","doi-asserted-by":"crossref","DOI":"10.1016\/j.medengphy.2019.09.014","type":"other","article-title":"The neochord mitral valve repair procedure: numerical simulation of different neochords tensioning protocols","author":"Di Micco","year":"2019"},{"key":"bib0028","first-page":"1958","type":"other","article-title":"Degenerative mitral valve regurgitation: best practice revolution","volume":"31","author":"Adams","year":"2010"},{"key":"bib0029","first-page":"757","type":"other","article-title":"Comparative histopathological analysis of mitral valves in barlow disease and fibroelastic deficiency","volume":"28","author":"Hjortnaes","year":"2016"},{"key":"bib0030","first-page":"6270","type":"other","article-title":"Automatic segmentation of right ventricle in cardiac cine MR images using a saliency analysis","volume":"43","author":"Atehortua","year":"2016"},{"key":"bib0031","first-page":"1","type":"other","article-title":"Personalized computational modeling of mitral valve prolapse: virtual leaflet resection","volume":"10","author":"Rim","year":"2015"},{"key":"bib0032","first-page":"230","type":"other","article-title":"Acute intraoperative echocardiographic changes after transapical off-pump mitral valve repair with NeoChord implantation","volume":"257","author":"Colli","year":"2018"},{"key":"bib0033","first-page":"e199","type":"other","article-title":"Patient-specific ventricular access site selection for the NeoChord mitral valve repair procedure","volume":"104","author":"Colli","year":"2017"},{"key":"bib0034","first-page":"235","type":"other","article-title":"Prognostic impact of leaflet-to-annulus index in patients treated with transapical off-pump echo-guided mitral valve repair with NeoChord implantation","volume":"257","author":"Colli","year":"2018"},{"key":"bib0035","first-page":"273","type":"other","article-title":"Learning curve analysis of transapical NeoChord mitral valve repair\u2020","volume":"54","author":"Colli","year":"Aug. 2018"},{"key":"bib0036","first-page":"22","type":"other","article-title":"Harpoon repair for mitral regurgitation\u00a0: a case report","volume":"3","author":"Talukder","year":"2018"},{"key":"bib0037","first-page":"871","type":"other","article-title":"Transoesophageal echo-guided mitral valve repair using the Harpoon system","volume":"53","author":"Gerosa","year":"2018"},{"key":"bib0038","first-page":"136","type":"other","article-title":"Replacement of mitral valve posterior chordae tendineae with expanded polytetrafluoroethylene suture: a finite element study","volume":"11","author":"Kunzelman","year":"1996"},{"key":"bib0039","first-page":"1057","type":"other","article-title":"Medical engineering & physics mitral valve dynamics in structural and fluid \u2013 structure interaction models","volume":"32","author":"Lau","year":"2010"},{"key":"bib0040","doi-asserted-by":"crossref","DOI":"10.1016\/j.medengphy.2019.09.014","type":"other","article-title":"The neochord mitral valve repair procedure: numerical simulation of different neochords tensioning protocols","author":"di Micco","year":"2019"},{"key":"bib0041","first-page":"85","type":"other","article-title":"The clinical anatomy of the mitral valve","volume":"22","author":"Muresian","year":"2009"},{"key":"bib0042","first-page":"3411","type":"other","article-title":"Mitral valve finite-element modelling from ultrasound data: a pilot study for a new approach to understand mitral function and clinical scenarios","volume":"366","author":"Votta","year":"2008"},{"key":"bib0043","first-page":"914","type":"other","article-title":"Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the tact trial (transapical artificial chordae tendinae) proof of concept","volume":"63","author":"Seeburger","year":"2014"},{"key":"bib0044","first-page":"1397","type":"other","article-title":"CT for the transapical off-pump mitral valve repair with neochord implantation procedure","volume":"10","author":"Colli","year":"2017"},{"key":"bib0045","first-page":"843","author":"Colli","year":"2018","type":"other"},{"key":"bib0046","first-page":"991","type":"other","article-title":"Beating heart mitral valve repair with neochordae implantation: real-time monitoring of haemodynamic recovery","volume":"52","author":"Colli","year":"Nov. 2017"},{"key":"bib0047","first-page":"914","type":"other","article-title":"Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the tact trial (transapical artificial chordae tendinae) proof of concept","volume":"63","author":"Seeburger","year":"Mar. 2014"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322000248?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322000248?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103773","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103773\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103773\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103773\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:55:05Z","timestamp":1769093705000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103773"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,11]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,2,11]]},"published-print":{"date-parts":[[2022,3,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2022.103773","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,11]]},"assertion":[{"value":"Beating heart implantation of transventricular artificial cordae: How can access site selection and leaflet insertion improve mitral regurgitation correction?","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-04-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-02-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-02-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}