{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T22:34:24Z","timestamp":1789684464747,"version":"4.0.1"},"reference-count":43,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2022,8,23]],"date-time":"2022-08-23T00:00:00Z","timestamp":1661212800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2022,8,23]],"date-time":"2022-08-23T00:00:00Z","timestamp":1661212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100012041","name":"Versus Arthritis","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012041","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100006041","name":"Innovate UK","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006041","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2022,10,1]]},"DOI":"10.1016\/j.medengphy.2022.103875","type":"journal-article","created":{"date-parts":[[2022,8,22]],"date-time":"2022-08-22T23:00:32Z","timestamp":1661209232000},"page":"103875","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":12,"title":["Personalised 3D Printed high tibial osteotomy achieves a high level of accuracy: \u2018\n                    <i>IDEAL<\/i>\n                    \u2019 preclinical stage evaluation of a novel patient specific system"],"prefix":"10.1088","volume":"108","author":[{"given":"A.R.","family":"MacLeod","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.I.","family":"Mandalia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.A.","family":"Mathews","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.D.","family":"Toms","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.S.","family":"Gill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,8,23]]},"reference":[{"key":"bib0001","first-page":"1548","type":"other","article-title":"Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies","volume":"90","author":"Brinkman","year":"2008"},{"key":"bib0002","first-page":"276","type":"other","article-title":"Complications associated with opening wedge high tibial osteotomy - A review of the literature and of 15 years of experience","volume":"23","author":"Woodacre","year":"2016"},{"key":"bib0003","first-page":"254","type":"other","article-title":"3D printing and high tibial osteotomy","volume":"3","author":"Jones","year":"2018"},{"key":"bib0004","first-page":"925","type":"other","article-title":"How accurately does high tibial osteotomy correct the mechanical axis of an arthritic varus knee? A systematic review","volume":"23","author":"Van den Bempt","year":"2016"},{"key":"bib0005","first-page":"3387","type":"other","article-title":"Role of computer-assisted surgery in osteotomies around the knee","volume":"24","author":"Saragaglia","year":"2016"},{"key":"bib0006","type":"other","article-title":"Plate removal without loss of correction after open-wedge high tibial osteotomy is possible when posterior cortex bone union reaches osteotomy gap center even in incompletely filled gaps","volume":"28","author":"Goshima","year":"2020"},{"key":"bib0007","first-page":"245","type":"other","article-title":"Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study","volume":"103","author":"Munier","year":"2017"},{"key":"bib0008","first-page":"639","type":"other","article-title":"The effect of plate design, bridging span, and fracture healing on the performance of high tibial osteotomy plates an experimental and finite element study","volume":"7","author":"MacLeod","year":"2018"},{"key":"bib0009","first-page":"607","type":"other","article-title":"Practical guide to the idea, development and exploration stages of the IDEAL framework and recommendations","volume":"103","author":"Pennell","year":"2016"},{"key":"bib0010","doi-asserted-by":"crossref","DOI":"10.1097\/SLA.0000000000002794","type":"other","article-title":"No surgical innovation without evaluation: evolution and further development of the IDEAL framework and recommendations","author":"Hirst","year":"2019"},{"key":"bib0011","type":"other","article-title":"Personalised high tibial osteotomy has mechanical safety equivalent to generic device in a case\u2013control in silico clinical trial","volume":"1","author":"MacLeod","year":"2021"},{"key":"bib0012","type":"other","article-title":"Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy","volume":"7","author":"Fucentese","year":"2020"},{"key":"bib0013","type":"other","article-title":"Is patient-specific instrumentation more precise than conventional techniques and navigation in achieving planned correction in high tibial osteotomy?","volume":"106","author":"Tardy","year":"2020"},{"key":"bib0014","type":"other","article-title":"Lower limb malrotation is regularly present in long-leg radiographs resulting in significant measurement errors","volume":"34","author":"Maderbacher","year":"2021"},{"key":"bib0015","first-page":"297","type":"other","article-title":"Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy","volume":"131","author":"Gebhard","year":"2011"},{"key":"bib0016","first-page":"649","type":"other","article-title":"Complications in high tibial (medial opening wedge) osteotomy","volume":"124","author":"Spahn","year":"2004"},{"key":"bib0017","first-page":"113","type":"other","article-title":"Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques","volume":"21","author":"Iorio","year":"2013"},{"key":"bib0018","first-page":"215","type":"other","article-title":"Normal axial alignment of the lower extremity and load-bearing distribution at the knee","author":"Hsu","year":"1990"},{"key":"bib0019","first-page":"155","type":"other","article-title":"Results of high tibial osteotomy: review of the literature","volume":"34","author":"Amendola","year":"2010"},{"key":"bib0020","first-page":"2041","type":"other","article-title":"High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci's method","volume":"23","author":"Elson","year":"2015"},{"key":"bib0021","first-page":"1081","type":"other","article-title":"Evaluation of a CT-based technique to measure the transfer accuracy of a virtually planned osteotomy","volume":"36","author":"Dobbe","year":"2014"},{"key":"bib0022","first-page":"117","type":"other","article-title":"Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study","volume":"15","author":"L\u00fctzner","year":"2010"},{"key":"bib0023","first-page":"349","type":"other","article-title":"Computer-assisted navigation in high tibial osteotomy","volume":"8","author":"Song","year":"2016"},{"key":"bib0024","first-page":"3410","type":"other","article-title":"Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement","volume":"24","author":"Schr\u00f6ter","year":"2016"},{"key":"bib0025","first-page":"181","type":"other","article-title":"Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique","volume":"21","author":"Reising","year":"2013"},{"key":"bib0026","first-page":"917","type":"other","article-title":"Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study","volume":"14","author":"Hankemeier","year":"2006"},{"key":"bib0027","first-page":"586","type":"other","article-title":"Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method","volume":"20","author":"Akamatsu","year":"2012"},{"key":"bib0028","first-page":"451","type":"other","article-title":"The use of navigation in osteotomies around the knee","volume":"38","author":"Neri","year":"2019"},{"key":"bib0029","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/9246529","type":"other","article-title":"Clinical experience using a 3D-printed patient-specific instrument for medial opening wedge high tibial osteotomy","author":"Yang","year":"2018"},{"key":"bib0030","first-page":"2757","type":"other","article-title":"Patient-specific cutting guides for open-wedge high tibial osteotomy: safety and accuracy analysis of a hundred patients continuous cohort","volume":"43","author":"Chaouche","year":"2019"},{"key":"bib0031","type":"other","article-title":"Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study","volume":"13","author":"Donnez","year":"2018"},{"key":"bib0032","first-page":"153","type":"other","article-title":"Virtual 3D planning and patient specific surgical guides for osteotomies around the knee: a feasibility and proof-of-concept study","volume":"95-B","author":"Victor","year":"2013"},{"key":"bib0033","first-page":"743","type":"other","article-title":"A CAD\/CAM-prototyped anatomical condylar prosthesis connected to a custom-made bone plate to support a fibula free flap","volume":"50","author":"Ciocca","year":"2012"},{"key":"bib0034","first-page":"196","type":"other","article-title":"Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study","volume":"10","author":"Omori","year":"2014"},{"key":"bib0035","first-page":"3452","type":"other","article-title":"More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy","volume":"26","author":"Kim","year":"2018"},{"key":"bib0036","first-page":"866","type":"other","article-title":"A pilot study to assess the safety and radiological performance of a new low-profile locking plate for high tibial osteotomy","volume":"25","author":"Pagkalos","year":"2018"},{"key":"bib0037","first-page":"217","type":"other","article-title":"Stability of medial opening wedge high tibial osteotomy: a failure analysis","volume":"34","author":"Nelissen","year":"2010"},{"key":"bib0038","first-page":"796","type":"other","article-title":"Two-year results of open-wedge high tibial osteotomy with fixation by medial plate fixator for medial compartment arthritis with varus malalignment of the knee","volume":"24","author":"Niemeyer","year":"2008"},{"key":"bib0039","first-page":"1648","type":"other","article-title":"Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating","volume":"45","author":"R\u00f6derer","year":"2014"},{"key":"bib0040","first-page":"1513","type":"other","article-title":"Very low-dose computed tomography for planning and outcome measurement in knee replacement. The Imperial knee protocol","volume":"88-B","author":"Henckel","year":"2006"},{"key":"bib0041","first-page":"1","type":"other","article-title":"Healing period after open high tibial osteotomy and related factors: can we really say that it is long?","volume":"5","author":"Yokoyama","year":"2016"},{"key":"bib0042","first-page":"158","type":"other","article-title":"Excursion of oscillating saw blades in total knee arthroplasty","volume":"25","author":"Dimitris","year":"2010"},{"key":"bib0043","first-page":"682","type":"other","article-title":"The effect of computed tomographic scanner parameters and 3-dimensional volume rendering techniques on the accuracy of linear, angular, and volumetric measurements of the mandible","volume":"115","author":"Whyms","year":"2013"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322001230?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322001230?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103875","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103875\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103875\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103875\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:56:05Z","timestamp":1769093765000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103875"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,23]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,8,23]]},"published-print":{"date-parts":[[2022,10,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2022.103875","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,23]]},"assertion":[{"value":"Personalised 3D Printed high tibial osteotomy achieves a high level of accuracy: \u2018\n                      IDEAL\n                      \u2019 preclinical stage evaluation of a novel patient specific system","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-02-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-08-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-08-23","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}