{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T07:05:42Z","timestamp":1783580742879,"version":"3.55.0"},"reference-count":29,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2022,10,17]],"date-time":"2022-10-17T00:00:00Z","timestamp":1665964800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2022,10,17]],"date-time":"2022-10-17T00:00:00Z","timestamp":1665964800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000857","name":"Loughborough University","doi-asserted-by":"publisher","award":["EP\/R001650\/1"],"award-info":[{"award-number":["EP\/R001650\/1"]}],"id":[{"id":"10.13039\/501100000857","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2022,11,1]]},"DOI":"10.1016\/j.medengphy.2022.103909","type":"journal-article","created":{"date-parts":[[2022,10,17]],"date-time":"2022-10-17T03:08:31Z","timestamp":1665976111000},"page":"103909","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["<i>In silico<\/i>\n                    evaluation of additively manufactured 316L stainless steel stent in a patient-specific coronary artery"],"prefix":"10.1088","volume":"109","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5002-0411","authenticated-orcid":true,"given":"Ran","family":"He","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9920-2830","authenticated-orcid":true,"given":"Enzoh","family":"Langi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebecca","family":"Garrard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7074-9522","authenticated-orcid":true,"given":"Moataz M.","family":"Attallah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3338-3311","authenticated-orcid":true,"given":"Vadim V.","family":"Silberschmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7334-8006","authenticated-orcid":true,"given":"Felix","family":"Vogt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liguo","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,10,17]]},"reference":[{"key":"bib0001","first-page":"137","type":"other","article-title":"A survey of stent designs","volume":"11","author":"Stoeckel","year":"2009"},{"key":"bib0002","doi-asserted-by":"crossref","DOI":"10.1016\/j.msec.2021.112462","type":"other","article-title":"Pioneering personalised design of femoropopliteal nitinol stents","author":"He","year":"2021"},{"key":"bib0003","first-page":"172","type":"other","article-title":"Additive manufacturing (3D printing): a review of materials, methods, applications and challenges","volume":"143","author":"Ngo","year":"2018"},{"key":"bib0004","first-page":"338","type":"other","article-title":"Additive manufacturing of cardiovascular CoCr stents by selective laser melting","volume":"119","author":"Demir","year":"2017"},{"key":"bib0005","first-page":"16","type":"other","article-title":"Design rules for producing cardiovascular stents by selective laser melting: geometrical constraints and opportunities","volume":"15","author":"Finazzi","year":"2019"},{"key":"bib0006","type":"other","article-title":"Effect of selective laser melting on microstructure, mechanical, and corrosion properties of biodegradable FeMnCS for implant applications","volume":"22","author":"Hufenbach","year":"2020"},{"key":"bib0007","first-page":"161","type":"other","article-title":"Design and functional testing of a novel balloon-expandable cardiovascular stent in CoCr alloy produced by selective laser melting","volume":"55","author":"Finazzi","year":"2020"},{"key":"bib0008","type":"other","article-title":"Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents","volume":"15","author":"Wiesent","year":"2020"},{"key":"bib0009","type":"other","article-title":"Computational analysis of the effects of geometric irregularities on the interaction of an additively manufactured 316L stainless steel stent and a coronary artery","volume":"125","author":"Wiesent","year":"2022"},{"key":"bib0010","first-page":"1739","type":"other","article-title":"Coronary in-stent restenosis\u2014predictors, treatment and prevention","volume":"21","author":"Hoffmann","year":"2000"},{"key":"bib0011","first-page":"149","type":"other","article-title":"Mechanisms of angioplasty and stent restenosis: implications for design of rational therapy","volume":"91","author":"Bennett","year":"2001"},{"key":"bib0012","type":"other","article-title":"Multiscale modeling of vascular remodeling induced by wall shear stress","volume":"12","author":"Chen","year":"2022"},{"key":"bib0013","type":"other","article-title":"Model construction and numerical simulation of arterial remodeling after stent implantation with variations of cell concentration","volume":"16","author":"Zhang","year":"2022"},{"key":"bib0014","first-page":"981","type":"other","article-title":"3-Year clinical follow-up of the RIBS IV clinical trial: a prospective randomized study of drug-eluting balloons versus everolimus-eluting stents in patients with in-stent restenosis in coronary arteries previously treated with drug-eluting stents","volume":"11","author":"Alfonso","year":"2018"},{"key":"bib0015","type":"other","article-title":"Mean corpuscular volume predicts in-stent restenosis risk for stable coronary artery disease patients receiving elective percutaneous coronary intervention","volume":"25","author":"Sun","year":"2019"},{"key":"bib0016","first-page":"1","type":"other","article-title":"Development and validation of a risk prediction nomogram for in-stent restenosis in patients undergoing percutaneous coronary intervention","volume":"21","author":"He","year":"2021"},{"key":"bib0017","doi-asserted-by":"publisher","first-page":"757","DOI":"10.4103\/0366-6999.228247\/ASSET\/25EB8211-F963-4DC6-A96D-7683C3229854\/ASSETS\/GRAPHIC\/0366-6999-131-07-101-F002.PNG","type":"other","article-title":"Platelet distribution width on admission predicts in-stent restenosis in patients with coronary artery disease and type 2 diabetes mellitus treated with percutaneous coronary intervention","volume":"131","author":"Hu","year":"2018"},{"key":"bib0018","type":"other","article-title":"Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis","volume":"109","author":"He","year":"2020"},{"key":"bib0019","first-page":"2048","type":"other","article-title":"Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling","volume":"289","author":"Holzapfel","year":"2005"},{"key":"bib0020","first-page":"254","type":"other","article-title":"Effect of two-year degradation on mechanical interaction between a bioresorbable scaffold and blood vessel","volume":"78","author":"Qiu","year":"2018"},{"key":"bib0021","first-page":"253","author":"Poncin","year":"2004","type":"other"},{"key":"bib0022","first-page":"1425","type":"other","article-title":"Mechanistic evaluation of long-term in-stent restenosis based on models of tissue damage and growth","volume":"19","author":"He","year":"2020"},{"key":"bib0023","type":"other"},{"key":"bib0024","first-page":"86","type":"other","article-title":"On the finite element modelling of balloon-expandable stents","volume":"1","author":"Ju","year":"2008"},{"key":"bib0025","first-page":"2974","type":"other","article-title":"Morphological predictors of restenosis after coronary stenting in humans","volume":"105","author":"Farb","year":"2002"},{"key":"bib0026","first-page":"627","type":"other","article-title":"Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation","volume":"100","author":"Lee","year":"2007"},{"key":"bib0027","first-page":"614","type":"other","article-title":"Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis?","volume":"71","author":"Shaikh","year":"2008"},{"key":"bib0028","first-page":"1082","type":"other","article-title":"Outcomes of drug-eluting stent thrombosis after treatment for acute versus chronic coronary syndrome","volume":"14","author":"Yamamoto","year":"2021"},{"key":"bib0029","first-page":"793","type":"other","article-title":"Uniaxial tensile testing approaches for characterisation of atherosclerotic plaques","volume":"47","author":"Walsh","year":"2014"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322001576?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453322001576?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103909","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103909\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103909\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103909\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:56:37Z","timestamp":1769093797000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2022.103909"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,17]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,10,17]]},"published-print":{"date-parts":[[2022,11,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2022.103909","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,17]]},"assertion":[{"value":"In silico\n                      evaluation of additively manufactured 316L stainless steel stent in a patient-specific coronary artery","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-07-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-10-13","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-10-17","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}