{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T01:19:11Z","timestamp":1789003151396,"version":"build-2803163510"},"reference-count":31,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T00:00:00Z","timestamp":1704153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T00:00:00Z","timestamp":1704153600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000054","name":"National Cancer Institute","doi-asserted-by":"publisher","award":["P30 CA008748"],"award-info":[{"award-number":["P30 CA008748"]}],"id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2024,2,1]]},"DOI":"10.1016\/j.medengphy.2024.104100","type":"journal-article","created":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T12:05:22Z","timestamp":1704197122000},"page":"104100","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Finite element investigation of the influence of a new transpedicular vertebral implant positioning on biomechanical responses of the spine segment"],"prefix":"10.1088","volume":"124","author":[{"given":"Ridha","family":"Hambli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reade","family":"De Leacy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1058-0884","authenticated-orcid":true,"given":"Fran\u00e7ois","family":"Cornelis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C\u00e9cile","family":"Vienney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,1,2]]},"reference":[{"key":"bib0001","first-page":"2S","type":"other","article-title":"Epidemiology of spinal osteoporosis","volume":"22","author":"Melton","year":"1997"},{"key":"bib0002","first-page":"79","type":"other","article-title":"Risk of subsequent fracture after prior fracture among older women","volume":"30","author":"Balasubramanian","year":"2019"},{"key":"bib0003","first-page":"42S","type":"other","article-title":"Clinical consequences of vertebral fractures","author":"Ross","year":"1997"},{"key":"bib0004","first-page":"205","type":"other","article-title":"Vertebral compression fractures: a review of current management and multimodal therapy","volume":"6","author":"Wong","year":"2013"},{"key":"bib0005","first-page":"40","type":"other","article-title":"Comparative biomechanical study of a new transpedicular vertebral device and vertebroplasty for the treatment or prevention of vertebral compression fractures","volume":"56","author":"Aebi","year":"2018"},{"key":"bib0006","first-page":"642","type":"other","article-title":"Percutaneous transpedicular fixation by PEEK polymer implants combined with cementoplasty for vertebral compression fractures: a pilot study","volume":"44","author":"Cornelis","year":"2021"},{"key":"bib0007","first-page":"303","type":"other","article-title":"Late failure of posterior fixation without bone fusion for vertebral metastases","volume":"23","author":"Bellato","year":"2015"},{"key":"bib0008","first-page":"2339","type":"other","article-title":"Long-term mechanical results of partial thoracic vertebrectomies with posterior instrumentation only after en bloc tumoral resection","volume":"25","author":"Glorion","year":"2016"},{"key":"bib0009","first-page":"166","type":"other","article-title":"Hardware failure in patients with metastatic cancer to the spine","volume":"45","author":"Pedreira","year":"2017"},{"key":"bib0010","first-page":"66","type":"other","article-title":"Revision surgery for instrumentation failure after total en bloc spondylectomy: a retrospective case series","volume":"21","author":"Shinmura","year":"2020"},{"key":"bib0011","first-page":"878","type":"other","article-title":"Incidence and risk factors for implant failure in spinal metastasis surgery","volume":"14","author":"Wong","year":"2020"},{"key":"bib0012","first-page":"31","type":"other","article-title":"Risk factors of instrumentation failure after multilevel total en bloc spondylectomy","volume":"1","author":"Yoshioka","year":"2017"},{"key":"bib0013","first-page":"e441","type":"other","article-title":"Finite element analysis of 3 posterior fixation techniques in the lumbar spine","volume":"37","author":"Gong","year":"2014"},{"key":"bib0014","first-page":"1459","type":"other","article-title":"Finite element analysis of Stryker Xia pedicle screw in artificial bone samples with and without supplemental cement augmentation","volume":"18","author":"Pfeiffer","year":"2015"},{"key":"bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.clinbiomech.2023.105893","type":"other","article-title":"Effect of a new transpedicular vertebral device for the treatment or prevention of vertebral compression fractures: a finite element study","author":"Hambli","year":"2023"},{"key":"bib0016","type":"other","article-title":"Three-dimensional biomechanical finite element analysis of lumbar disc herniation in middle aged and elderly","volume":"15","author":"Wan","year":"2022"},{"key":"bib0017","first-page":"755","type":"other","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999"},{"key":"bib0018","first-page":"1757","type":"other","article-title":"Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together","volume":"47","author":"Dreischarf","year":"2014"},{"key":"bib0019","first-page":"897","type":"other","article-title":"Trabecular bone modulus-density relationships depend on anatomic site","volume":"36","author":"Morgan","year":"2003"},{"key":"bib0020","first-page":"377","type":"other","article-title":"Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment","volume":"22","author":"Schmidt","year":"2007"},{"key":"bib0021","first-page":"1351","type":"other","article-title":"Biomechanical properties of human lumbar spine ligaments","volume":"25","author":"Pintar","year":"1992"},{"key":"bib0022","first-page":"205","type":"other","article-title":"Effect of strain rate and bone mineral on the structural properties of the human anterior longitudinal ligament","volume":"19","author":"Neumann","year":"1994"},{"key":"bib0023","first-page":"991","type":"other","article-title":"The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis","volume":"28","author":"Polikeit","year":"2003"},{"key":"bib0024","first-page":"253","type":"other","article-title":"Numerical comparison of restored vertebral body height after incomplete burst fracture of the lumbar spine","volume":"12","author":"Jhong","year":"2022"},{"key":"bib0025","first-page":"3208","type":"other","article-title":"Case-specific non-linear finite element models to predict failure behavior in two functional spinal units","volume":"36","author":"Groenen","year":"2018"},{"key":"bib0026","first-page":"3","type":"other","article-title":"A 2003 update of bone physiology and Wolff's Law for clinicians","volume":"74","author":"Frost","year":"2004"},{"key":"bib0027","first-page":"64","type":"other","article-title":"Computational contact pressure prediction of CoCrMo, SS 316L and Ti6Al4V femoral head against UHMWPE acetabular cup under gait cycle","volume":"13","author":"Jamari","year":"2022"},{"key":"bib0028","first-page":"2271","type":"other","article-title":"Parameters influencing the outcome after total disc replacement at the lumbosacral junction. Part 1: misalignment of the vertebrae adjacent to a total disc replacement affects the facet joint and facet capsule forces in a probabilistic finite element analysis","volume":"22","author":"Rohlmann","year":"2013"},{"key":"bib0029","first-page":"175","type":"other","article-title":"Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body","volume":"25","author":"Lin","year":"2004"},{"key":"bib0030","first-page":"1782","type":"other","article-title":"A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study)","volume":"19","author":"Noriega","year":"2019"},{"key":"bib0031","first-page":"524","type":"other","article-title":"Analysis of adjacent fractures after two-level percutaneous vertebroplasty: is the intervening vertebral body prone to te-fracture?","volume":"12","author":"Han","year":"2018"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S135045332400002X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S135045332400002X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104100","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104100\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104100\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104100\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:02:01Z","timestamp":1769094121000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104100"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,2]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1,2]]},"published-print":{"date-parts":[[2024,2,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2024.104100","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,2]]},"assertion":[{"value":"Finite element investigation of the influence of a new transpedicular vertebral implant positioning on biomechanical responses of the spine segment","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-05-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-01","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}