{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T21:47:54Z","timestamp":1793742474669,"version":"4.6.1"},"reference-count":57,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T00:00:00Z","timestamp":1708473600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T00:00:00Z","timestamp":1708473600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100002322","name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003593","name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003593","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2024,3,1]]},"DOI":"10.1016\/j.medengphy.2024.104120","type":"journal-article","created":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T11:38:55Z","timestamp":1708515535000},"page":"104120","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Novel tetrapolar single-needle electrode for electrochemotherapy in bone cavities: Modeling, design and validation"],"prefix":"10.1088","volume":"125","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2368-1297","authenticated-orcid":true,"given":"Lucas B.","family":"Lopes","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6920-0049","authenticated-orcid":true,"given":"Guilherme B.","family":"Pintarelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2466-5061","authenticated-orcid":true,"given":"Raul","family":"Guedert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniella L.L.S.","family":"Andrade","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Afr\u00e2nio C.","family":"Antonio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7531-5486","authenticated-orcid":true,"given":"Clara T.S.","family":"Ramos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00e9ssica R.","family":"da Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcelo M.M.","family":"Rangel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela O.H.","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,2,21]]},"reference":[{"key":"br0010","first-page":"439","type":"other","article-title":"Calculation of the electrical parameters in electrochemotherapy of solid tumours in mice","volume":"28","author":"\u0160emrov","year":"1998"},{"key":"br0020","first-page":"3415","type":"other","article-title":"Electrochemotherapy in head and neck cancer: a review of an emerging cancer treatment","volume":"16","author":"De Virgilio","year":"2018"},{"key":"br0030","first-page":"2019","type":"other","article-title":"Electrochemotherapy: a review of current status, alternative igp approaches, and future perspectives","author":"Esmaeili","year":"2019"},{"key":"br0040","first-page":"135","type":"other","article-title":"Theory of electroporation: a review","volume":"41","author":"Weaver","year":"1996"},{"key":"br0050","first-page":"14","type":"other","article-title":"Cell membrane electroporation-part 1: the phenomenon","volume":"28","author":"Kotnik","year":"2012"},{"key":"br0060","first-page":"1","type":"other","article-title":"Electrochemotherapy (ect) and irreversible electroporation (ire)-advanced techniques for treating deep-seated tumors based on electroporation","volume":"14","author":"Davalos","year":"2015"},{"key":"br0070","first-page":"1","type":"other","article-title":"Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by \u201celectric field sinks\u201d","volume":"5","author":"Golberg","year":"2015"},{"key":"br0080","first-page":"142","type":"other","article-title":"Electrochemotherapy: advantages and drawbacks in treatment of cancer patients","volume":"1","author":"Sersa","year":"2003"},{"key":"br0090","first-page":"295","type":"other","article-title":"Electroporation-based technologies for medicine: principles, applications, and challenges","volume":"16","author":"Yarmush","year":"2014"},{"key":"br0100","first-page":"14","type":"other","article-title":"Standard operating procedures of the electrochemotherapy: instructions for the use of bleomycin or cisplatin administered either systemically or locally and electric pulses delivered by the cliniporatorTM by means of invasive or non-invasive electrodes","volume":"4","author":"Mir","year":"2006"},{"key":"br0110","first-page":"874","type":"other","article-title":"Updated standard operating procedures for electrochemotherapy of cutaneous tumours and skin metastases","volume":"57","author":"Gehl","year":"2018"},{"key":"br0120","first-page":"147","type":"other","article-title":"Robustness of treatment planning for electrochemotherapy of deep-seated tumors","volume":"236","author":"Kos","year":"2010"},{"key":"br0130","first-page":"1","type":"other","article-title":"Towards treatment planning and treatment of deep-seated solid tumors by electrochemotherapy","volume":"9","author":"Miklavcic","year":"2010"},{"key":"br0140","first-page":"265","type":"other","article-title":"Patient-specific treatment planning of electrochemotherapy: procedure design and possible pitfalls","volume":"87","author":"Pavliha","year":"2012"},{"key":"br0150","first-page":"2152","type":"other","article-title":"The importance of electric field distribution for effective in vivo electroporation of tissues","volume":"74","author":"Miklav\u010di\u010d","year":"1998"},{"key":"br0160","first-page":"45","type":"other","article-title":"Importance of tumour coverage by sufficiently high local electric field for effective electrochemotherapy","volume":"4","author":"Miklavcic","year":"2006"},{"key":"br0170","first-page":"393","type":"other","article-title":"Importance of contact surface between electrodes and treated tissue in electrochemotherapy","volume":"7","author":"\u010corovi\u0107","year":"2008"},{"key":"br0180","first-page":"767","type":"other","article-title":"Novel application for electrochemotherapy: immersion of nasal cavity in dog","volume":"41","author":"Suzuki","year":"2017"},{"key":"br0190","first-page":"309","type":"other","article-title":"Adjuvant electrochemotherapy after debulking in canine bone osteosarcoma infiltration","volume":"45","author":"Taques","year":"2021"},{"key":"br0200","first-page":"133","type":"other","article-title":"Computer optimization of conductive gels for electrochemotherapy","volume":"98","author":"Lopes","year":"2021"},{"key":"br0210","first-page":"1213","type":"other","article-title":"Electrochemotherapy: technological advancements for efficient electroporation-based treatment of internal tumors","volume":"50","author":"Miklav\u010di\u010d","year":"2012"},{"key":"br0220","first-page":"422","type":"other","article-title":"Minimally invasive electrochemotherapy procedure for treating nasal duct tumors in dogs using a single needle electrode","volume":"51","author":"Maglietti","year":"2017"},{"key":"br0230","first-page":"49","type":"other","article-title":"A prototype of a flexible grid electrode to treat widespread superficial tumors by means of electrochemotherapy","volume":"50","author":"Campana","year":"2016"},{"key":"br0240","first-page":"1489","author":"Oey","year":"2016","type":"other"},{"key":"br0250","first-page":"1665","type":"other","article-title":"Numerical modeling and optimization of electric field distribution in subcutaneous tumor treated with electrochemotherapy using needle electrodes","volume":"36","author":"Corovic","year":"2008"},{"key":"br0260","first-page":"1338","type":"other","article-title":"Three-dimensional finite-element analysis of Joule heating in electrochemotherapy and in vivo gene electrotransfer","volume":"16","author":"Lackovi\u0107","year":"2009"},{"key":"br0270","first-page":"475","type":"other","article-title":"In vitro and numerical support for combinatorial irreversible electroporation and electrochemotherapy glioma treatment","volume":"42","author":"Neal","year":"2014"},{"key":"br0280","first-page":"1","type":"other","article-title":"Modeling of electric field distribution in tissues during electroporation","volume":"12","author":"Corovic","year":"2013"},{"key":"br0290","first-page":"2766","type":"other","article-title":"Electrochemotherapy treatment safety under parallel needle deflection","volume":"12","author":"Andrade","year":"2022"},{"key":"br0300","first-page":"816","type":"other","article-title":"Sequential finite element model of tissue electropermeabilization","volume":"52","author":"Sel","year":"2005"},{"key":"br0310","first-page":"1373","type":"other","article-title":"The course of tissue permeabilization studied on a mathematical model of a subcutaneous tumor in small animals","volume":"52","author":"Pavselj","year":"2005"},{"key":"br0320","type":"other","article-title":"The role of additional pulses in electropermeabilization protocols","volume":"9","author":"Su\u00e1rez","year":"2014"},{"key":"br0330","first-page":"224","type":"other","article-title":"Verification of electroporation models using the potato tuber as in vitro simulation","volume":"39","author":"Berkenbrock","year":"2019"},{"key":"br0340","first-page":"99","type":"other","article-title":"Computer simulation of commercial conductive gels and their application to increase the safety of electrochemotherapy treatment","volume":"74","author":"Pintarelli","year":"2019"},{"key":"br0350","doi-asserted-by":"crossref","DOI":"10.1108\/COMPEL-11-2012-0305","type":"other","article-title":"Electroporation of bone cancer: numerical evaluation of the electric field in treated tissues","author":"Bisceglia","year":"2013"},{"key":"br0360","first-page":"709","type":"other","article-title":"Irreversible electroporation of the lumbar vertebrae in a porcine model: is there clinical-pathologic evidence of neural toxicity?","volume":"272","author":"Tam","year":"2014"},{"key":"br0370","first-page":"586","type":"other","article-title":"Engineering and algorithm design for an image processing API: a technical report on ITK-the insight toolkit","volume":"85","author":"Yoo","year":"2002"},{"key":"br0380","first-page":"13","type":"other","article-title":"Itk: enabling reproducible research and open science","volume":"8","author":"McCormick","year":"2014"},{"key":"br0390","first-page":"3","type":"other","article-title":"Electrochemotherapy\u2013an easy, highly effective and safe treatment of cutaneous and subcutaneous metastases: results of esope (European standard operating procedures of electrochemotherapy) study","volume":"4","author":"Marty","year":"2006"},{"key":"br0400","first-page":"651","type":"other","article-title":"Electrochemotherapy for cutaneous and subcutaneous tumor lesions: a novel therapeutic approach","volume":"23","author":"Testori","year":"2010"},{"key":"br0410","first-page":"307","author":"Maglietti","year":"2021","type":"other"},{"key":"br0420","first-page":"5425","type":"other","article-title":"Treatment planning of electroporation-based medical interventions: electrochemotherapy, gene electrotransfer and irreversible electroporation","volume":"57","author":"Zupanic","year":"2012"},{"key":"br0430","first-page":"17","type":"other","article-title":"Computational feasibility analysis of electrochemotherapy with novel needle-electrode arrays for the treatment of invasive breast ductal carcinoma","author":"Vera-Tizatl","year":"2018"},{"key":"br0440","first-page":"107","type":"other","article-title":"Optimization of a single insertion electrode array for the creation of clinically relevant ablations using high-frequency irreversible electroporation","volume":"95","author":"Sano","year":"2018"},{"key":"br0450","type":"other","article-title":"Modeling of a single bipolar electrode with tines for irreversible electroporation delivery","volume":"142","author":"Zhao","year":"2022"},{"key":"br0460","author":"Pagano","year":"2021","type":"other"},{"key":"br0470","first-page":"300","type":"other","article-title":"Successful application of targeted electrochemotherapy using novel flexible electrodes and low dose bleomycin to solid tumours","volume":"232","author":"Soden","year":"2006"},{"key":"br0480","first-page":"2018","type":"other","article-title":"Electrochemotherapy effectiveness loss due to electric field indentation between needle electrodes: a numerical study","author":"Berkenbrock","year":"2018"},{"key":"br0490","first-page":"45","author":"Staal","year":"2011","type":"other"},{"key":"br0500","first-page":"8","type":"other","article-title":"Cell membrane electroporation-part 3: the equipment","volume":"30","author":"Rebersek","year":"2014"},{"key":"br0510","first-page":"296","type":"other","article-title":"Evaluation of the electroporation efficiency of a grid electrode for electrochemotherapy: from numerical model to in vitro tests","volume":"15","author":"Ongaro","year":"2016"},{"key":"br0520","first-page":"384","type":"other","article-title":"Electric field distribution in relation to cell membrane electroporation in potato tuber tissue studied by magnetic resonance techniques","volume":"37","author":"Kranjc","year":"2016"},{"key":"br0530","first-page":"287","type":"other","article-title":"In vivo electrical impedance measurements during and after electroporation of rat liver","volume":"70","author":"Ivorra","year":"2007"},{"key":"br0540","first-page":"688","type":"other","article-title":"Inclusion of memory effects in a dynamic model of electroporation in biological tissues","volume":"43","author":"Weinert","year":"2019"},{"key":"br0550","first-page":"727164","author":"Tellado","year":"2019","type":"other"},{"key":"br0560","type":"other","article-title":"Electroporation-based treatments in small animal veterinary oral and maxillofacial oncology","volume":"7","author":"Nemec","year":"2020"},{"key":"br0570","first-page":"187","type":"other","article-title":"Endoscopic and electroporation therapy of paranasal sinus tumors","volume":"14","author":"Panje","year":"2000"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000213?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000213?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104120","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104120\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104120\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104120\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:03:39Z","timestamp":1769094219000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104120"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,21]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,2,21]]},"published-print":{"date-parts":[[2024,3,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2024.104120","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,21]]},"assertion":[{"value":"Novel tetrapolar single-needle electrode for electrochemotherapy in bone cavities: Modeling, design and validation","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-08-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-21","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}